Crown DWT-20 Installation & Operation Manual

Crown DWT-20 Installation & Operation Manual

Direct steam wall mount tilting kettles

Advertisement

Quick Links

Installation & Operation Manual
Direct Steam Wall Mount Tilting Kettles
DWT-20, DWT-30, DWT-40, DWT-60,
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury
or death. Read the installation, operating and maintenance instructions thoroughly before installing or
M
R
ANUAL 10197
EV 0 (07/21)
$21.00
DWT-80 & DWT-100
servicing this equipment.
CROWN FOOD SERVICE EQUIPMENT
70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9
Telephone: 919-762-1000
Model DWT
WARNING
A Middleby Company
www.crownsteamgroup.com
DIRECT STEAM WALL MOUNT TILTING KETTLES
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this
manual for the life of the equipment:
Model #: ___________________________
Serial #: ___________________________
Date Purchased: _____________________
M
S
ANUAL
ECTION
CO

Advertisement

Table of Contents
loading

Summary of Contents for Crown DWT-20

  • Page 1 Model #: ___________________________ Serial #: ___________________________ Date Purchased: _____________________ Installation & Operation Manual Direct Steam Wall Mount Tilting Kettles DWT-20, DWT-30, DWT-40, DWT-60, DWT-80 & DWT-100 Model DWT WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
  • Page 2: Important Notes For Installation And Operation

    This product is intended for commercial use only. NOT FOR HOUSEHOLD USE. NOTICE This manual should be retained for future reference. Copyright © 2021 by Crown. All rights reserved. Published in the United States of America. PAGE OF 12 INSTALLATION & OPERATION MANUAL 10197 REV 0 (07/21)
  • Page 3: Table Of Contents

    Direct Steam Wall Mount Tilting Kettles Table of Contents RETAIN THIS MANUAL FOR FUTURE REFERENCE. Table of Contents Important Notes For Installation and Operation ..............2 Service Connections ......................4 INSTALLATION ........................5 INTRODUCTION ........................ 6 BASIC FUNCTIONING ....................... 6 OPERATION ........................
  • Page 4: Service Connections

    DWT-100 (379 liters) (mm) (902) (1524) (165) (762) (978) (432) (514) (2235) (1632) As continued product improvement is a policy of Crown, specifications are subject to changge without notice. PAGE OF 12 INSTALLATION & OPERATION MANUAL 10197 REV 0 (07/21)
  • Page 5: Installation

    12. A steam line pressure gauge is also recommended to determine the actual amount of steam being supplied to the kettle. 13. Check for proper operation. Kettle Model Weight of Empty Kettle (lb) Weight of Fully Loaded Kettle (lb) DWT-20 DWT-30 DWT-40 DWT-60 DWT-80 DWT-100 INSTALLATION &...
  • Page 6: Introduction

    Introduction Description All Crown direct connected steam jacketed kettles pertaining to this manual are direct steam operated pressure vessels of a double-wall stainless steel construction forming a steam chamber (jacket) enveloping the lower two thirds of the kettle bowl surface. All kettles are tilting, wall mounted in fixed positions. All kettles are equipped with a drain cock, safety relief valve and a steam control valve.
  • Page 7: Cleaning

    Direct Steam Wall Mount Tilting Kettles Cleaning Cleaning Cleaning Instructions WARNING Disconnect the power supply to the appliance before cleaning or servicing. WARNING Never spray water into electric controls or components! WARNING The equipment and its parts are hot. Use care when operating, cleaning and servicing. CAUTION Do not use cleaning agents that are corrosive.
  • Page 8 Direct Steam Wall Mount Tilting Kettles Dairy Draw-Off Valve Cleaning 1. Remove the plug by first removing the handle, then turn the plug to line up with the pin and pull with both hands. It is important to use both hands because the plug is heavy. 2.
  • Page 9 Direct Steam Wall Mount Tilting Kettles Stainless Steel To remove normal dirt, grease or product residue from stainless steel, use ordinary soap and water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean cloth. Never use vinegar or any other corrosive cleaner.
  • Page 10: Maintenance

    Maintenance Direct Steam Wall Mount Tilting Kettles Maintenance Safety Valve Maintenance and Testing CAUTION Under normal operating conditions a “try lever test” should be performed every two months. Under severe service conditions, or if corrosion and/or deposits are noticed within the valve body, testing must be performed more often. A “try lever test”...
  • Page 11: Troubleshooting

    Direct Steam Wall Mount Tilting Kettles Troubleshooting Troubleshooting DRAW-OFF VALVE LEAKS If a leak occurs through the valve steam, replace the “O” ring. If the leak can be attributed to faulty sealing occurring between the stem disc and valve seat, then quite often this problem can be corrected by cleaning off the dried on food residue with an extremely fine emery cloth or the rubber vulcanized stem piece has been damaged and must be replaced.
  • Page 12 Direct Steam Wall Mount Tilting Kettles A product with the Crown name incorporates the best in durability and low maintenance. We all recognize, however, that replacement parts and occasional professional service may be necessary to extend the useful life of this appliance.

This manual is also suitable for:

Dwt-30Dwt-40Dwt-60Dwt-80Dwt-100

Table of Contents