Table of Contents Parts List...............2 Operation............12-17 How to Start Engine........12 Introduction............3 How to Stop Engine........13 Product Specifications........3 Pairing Remote Fob.........13 Customer Service ..........3 Attaching Electronic Devices......14 Charging a 12 Volt Battery......14 Safety Rules............3-6 AC Parallel Operation........15 Safety Symbols..........3 Do Not Overload Generator........16 Wattage Reference Guide.......17 Safety Instructions..........4-6 Control Panel Functions........7-9...
Introduction Thank you for purchasing this 4500 watt portable Save your original sales receipt and record the inverter generator from JEGS. This generator is following information below for service or warranty designed to give you years of reliable service when assistance.
Safety Rules The engine exhaust contains chemicals The manufacturer cannot anticipate every possible circumstance that the user may encounter hazards. that can cause cancer and birth defects. Therefore, the warnings in this manual, on tags, • Always wash hands after handling generator. and on affixed decals are not all-inclusive.
Page 6
Safety Rules Cont. Keep away from flammable objects Avoid touching hot areas of this unit. and other hazardous materials. • Only operate the generator on a level surface. • The fuel and its vapors used to power this unit • If connected to a structure, connect the ground are highly flammable and could explode resulting terminal to an appropriate ground.
Page 7
Safety Rules Cont. Only use as intended. Used incorrectly serious injury or death could result. • Do not bypass any safety device. Moving parts are covered with guards. Make sure all protective covers are in place. • Never transport or make adjustments to this unit while it is running.
Control Panel Functions Fuel Valve Knob When the knob is in the “OFF” position, the fuel valve is closed and the engine will not run. When the knob is in the “ON” position, fuel valve is opened and the engine can run. USB Power Outlet The Generator offers convenient (5V DC 1.5A) USB outlet to allow charging of USB devices like Tablets,...
Parallel Connections enable the user electronic devices. When the DC Circuit Breaker is in to run two 86012 generators simultaneously. This the “O” position, the generator will no longer supply feature requires special cables and a parallel kit.
Control Panel Functions Cont. Fuel Cap Turn cap counterclockwise to remove. Fuel Cap Air Vent The fuel cap is equipped with an air vent to stop fuel from flowing to the carburetor. The Air Vent must be in the “ON” position to allow fuel to flow so that the engine can run.
Assembly Connecting the Generator to an Electrical System If you are connecting the generator to a building’s electrical system for standby power, you must use a qualified electrician to install a transfer switch. The power from the generator must be isolated from the circuit breaker or alternative power source.
Assembly Cont. Battery Installation 1. Loosen four Phillips screws, but do not remove them from the side panel. 2. Carefully lift all four edges of the side panel, releasing the clip; then lift it away. 3. Insert battery into the holder until it clicks firmly in place.
Operation Standard Atmospheric Conditions choke and begin the starting sequence. If it fails to start successfully, repeat this step. If it fails to • Ambient Temperature: 77º F (25º C) start after 5 attempts, refer to the “TROUBLE- • Barometric Pressure: 100 kPa SHOOTING”...
Operation Cont. Pull cord recoils quickly and could result in injury • To avoid recoil, pull the starter cord slowly until resistance is felt, then pull rapidly. Note: Steps to start the generator with the Economy switch in the “ON” position •...
Operation Cont. Never start or stop engine with electrical Charging a 12 Volt Battery devices plugged in to the receptacles. Failure to do so could damage the generator This generator can be used to charge 12 volt and / or connected electrical devices. automotive or storage batteries by taking the following steps.
This is normal. If the light stays on disconnect all electrical devices and stop the engine. AC Parallel Operation It is possible to connect two 86012 generators to Only connect electronic devices to the each other, using a parallel cable kit, to increase generator that are in good working order available power output.
Never connect generators that are different models. • Only connect to another 86002 Generator. • Only use a JEGS approved parallel operation cable kit to connect generators. • Never exceed maximum power , this setup may be used for no more than 30 minutes.
Operation Cont. Wattage Reference Guide (Wattages listed are approximate. Check electrical devices for actual wattage.) Rated Watts Surge Watts Rated Watts Essentials Family Room Surge Watts 75 W Light Bulbs 75 ea. 75 ea. X-Box or PlayStation 18 Cu. Ft. Refrigerator 2200 AM/FM Radio Furnace Fan (...
Maintenance Regular maintenance will extend the life of this After first 5 Change engine oil generator and improve its performance. The warranty Hours does not cover items that result from operator abuse, After 8 Hours Clean debris from generator misuse, or negligence. To receive full value from the or Daily and air filter area warranty, operator must maintain the generator as...
Maintenance Cont. • If spark plug is worn, replace only with an equivalent type. Spark plug should be replaced annually regardless of apparent condition. • Reconnect spark plug wire, firmly, until it clicks into place. Standard Spark Plug • Torch F6TC/F6RTC Spark Plug Gap •...
Maintenance Cont. Changing Oil Air Filter • Run the generator until the engine is warm, then A dirty air filter will reduce the lifespan of th engine, shut OFF. make it difficult to start and reduce performance. • Place generator on a firm and level surface, Replace with a new filter annually.
Maintenance Cont. Checking Muffler and Spark Arrester Fuel Tank Filter • Inspect the muffler for cracks, corrosion, or • To clean, remove fuel cap and filter. • Clean filter with gasoline. other damage. • Remove screws, then remove the muffler cover •...
Transport & Storage Storage and Transportation of the Generator How to Drain Fuel When transporting the generator, set the 3-in-1 • Turn OFF the engine, move the battery switch start switch to Off. Keep the generator level to to OFF, turn the fuel valve to OPEN, remove the prevent fuel spillage.
Troubleshooting Problem Cause Solution Generator is running, but 1. Open circuit breaker 1. Reset circuit breaker does not supply power. 2. Poor connection 2. Check and repair 3. Defective cord set 3. See above solution (#2) 4. Connected device is faulty 4.
Need help?
Do you have a question about the 86012 and is the answer not in the manual?
Questions and answers