Illusion MILLENIUM UGL32NG Owner's Instructions & Installation Manual

Illusion MILLENIUM UGL32NG Owner's Instructions & Installation Manual

Gas log heaters

Advertisement

Quick Links

Illusion Australia Pty. Ltd.
HEAD OFFICE
145 STH. GIPPSLAND HWY. DANDENONG
VICTORIA AUSTRALIA 3175
The Illusion
PH: (613) 9793 7520
Gas Log Fire
with
Email service@Illusionfires.com.au
PYROGLOW
www.Illusionfires.com.au
®
OWNERS INSTRUCTION & INSTALLATION MANUAL. PLEASE KEEP FOR FUTURE REFERENCE
MILLENIUM GAS LOG HEATERS
PYROGLOW® Gas Logs: ADVANTAGES- Realistic surface textures & colours. Radiant
natural glow of an actual fire when burning. Natural looking logs when idle. Superior strength
versus ceramic fibre.
Inert refractory formulation is ceramic fibre free. Pyroglow® logs create
virtually no fume emission. Thermal shock resistant. Contains no asbestos.
THESE APPLIANCES HAVE BEEN TESTED IN ACCORDANCE WITH AG 103 FOR
INSTALLATION AND OPERATION AS DESCRIBED IN THIS MANUAL AND HAVE BEEN
CERTIFIED BY THE AUSTRALIAN GAS ASSOCIATION.
WARNING:
All ILLusion Gas Log Appliances MUST be installed and serviced by an authorised installer or technician.
Unauthorised installation, service or maintenance may cause a hazardous situation.
MILLENIUM FREESTANDING MANUAL 2014

Advertisement

Table of Contents
loading

Summary of Contents for Illusion MILLENIUM UGL32NG

  • Page 1 INSTALLATION AND OPERATION AS DESCRIBED IN THIS MANUAL AND HAVE BEEN CERTIFIED BY THE AUSTRALIAN GAS ASSOCIATION. WARNING: All ILLusion Gas Log Appliances MUST be installed and serviced by an authorised installer or technician. Unauthorised installation, service or maintenance may cause a hazardous situation. MILLENIUM FREESTANDING MANUAL 2014...
  • Page 2: Table Of Contents

    The ILLUSION Gas Log Fire provides you with continuous warmth, and the traditional charm of a wood fired heater, without the hard work generally associated with a wood fuelled appliance. Safe and economical, you can rest easy knowing the ILLUSION Gas Log Fire has been fully tested and approved to AUSTRALIAN STANDARD AG 103.
  • Page 3 Q u a l i t y & Va l u e I n G a s L o g F i r e s UGL33NG, UGL33LP DIMENSIONS 496mm 453mm 698mm 670mm 552mm 36mm 50mm GAS INLET RHS REAR MILLENIUM FREESTANDING MANUAL 2014...
  • Page 4 Q u a l i t y & Va l u e I n G a s L o g F i r e s UGL40NG, UGL40LP DIMENSIONS 496mm 453mm 798mm 770mm 552mm 36mm 50mm GAS INLET RHS REAR MILLENIUM FREESTANDING MANUAL 2014...
  • Page 5 (for example, the flame failure device, limit thermostat and the like) must cut off the power supply to the thermoelectric circuit of the gas valve. Caution: After making the connections, check gas tightness. LABELLING ILLUSION GAS LOG HEATERS - MODELS UGL33NG, UGL40NG, UGL33LP AND UGL40LP Model UGL33NG UGL40NG...
  • Page 6: Lighting Instructions

    NEVER ATTEMPT TO LIGHT THE APPLIANCE IF YOU CAN SMELL GAS. IF IN DOUBT, CONTACT YOUR GAS SUPPLIER, APPLIANCE INSTALLER AND OR ILLUSION SERVICE DEPARTMENT FROM A NEIGHBOURS HOME. IF YOU CAN SMELL GAS, DO NOT USE MOBILE PHONES OR ANY ELECTRICAL APPLIANCE, OR ELECTRIC SWITCH IN THE BUILDING.
  • Page 7 Your ILLUSION sales representative can advise on the best position to maximize the performance of the appliance. In most cases, an Authorised ILLUSION Installer can be arranged to install the unit, however if this is not possible, a suitably qualified gas fitter must be used. These appliances are not designed to be installed by the homeowner.
  • Page 8: Installation Instructions

    Q u a l i t y & Va l u e I n G a s L o g F i r e s INSTALLATION INSTRUCTIONS NOTE THAT THIS GAS APPLIANCE MAY ONLY BE INSTALLED BY AN AUTHORISED GAS FITTER. CONTACT YOUR DEALER TO ARRANGE INSTALLATION. INSTALLATION PROCEDURE INSTALLERS CHECKLIST IMPORTANT: BEFORE COMMENCING THE INSTALLATION, ESTABLISH THE OPTIMAL POSITION...
  • Page 9: Installation Clearances

    Q u a l i t y & Va l u e I n G a s L o g F i r e s INSTALLATION CLEARANCES IMPORTANT: All distances shown are MINIMUM. ILLUSION Gas Log appliances UGL33NG ,UGL40NG, UGL33LP and UGL40LP must only be installed with the minimum distances shown below.
  • Page 10: Installation Examples

    Q u a l i t y & Va l u e I n G a s L o g F i r e s INSTALLATION EXAMPLES MILLENIUM FREESTANDING MANUAL 2014...
  • Page 11: Fitting The Logs & Coals Ugl33 (Continued)

    Q u a l i t y & Va l u e I n G a s L o g F i r e s FITTING THE LOG SET - MODELS UGL32NG, UGL32LP,UGL33NG,UGL33LP FITTING THE LOGS & COALS NOTE THAT THE COALS MUST BE PLACED ONTO THE MESH SUPPORT DURING INSTALLATION OF THE LOGS AND ARRANGED SO THAT BURNER HOLES ARE NOT BLOCKED.
  • Page 12 Q u a l i t y & Va l u e I n G a s L o g F i r e s FITTING THE LOG SET - MODELS UGL32NG, UGL32LP,UGL33NG,UGL33LP INSTALLATION SEQUENCE = 1-2-3-4-5-6 ADD COALS AS THE LOGS ARE NUMBERED ON THE LOGS ARE FITTED UNDERSIDE...
  • Page 13 Q u a l i t y & Va l u e I n G a s L o g F i r e s FITTING THE LOG SET - MODELS UGL39NG, UGL39LP,UGL40NG,UGL40LP FITTING THE LOGS & COALS NOTE THAT THE COALS MUST BE PLACED ONTO THE MESH SUPPORT DURING INSTALLATION OF THE LOGS AND ARRANGED SO THAT BURNER HOLES ARE NOT BLOCKED.
  • Page 14 Q u a l i t y & Va l u e I n G a s L o g F i r e s FITTING THE LOG SET - MODELS UGL39NG, UGL39LP,UGL40NG,UGL40LP INSTALLATION SEQUENCE = A-E-F-B-D-G-C ADD COALS AS THE LOGS ARE FITTED LOGS ARE NUMBERED ON THE UNDERSIDE...
  • Page 15: Pressure Testing

    Q u a l i t y & Va l u e I n G a s L o g F i r e s PRESSURE TESTING IMPORTANT: IF THE APPLIANCE CANNOT BE ADJUSTED TO OPERATE CORRECTLY, CONTACT YOUR SUPPLIER AND DO NOT OPERATE THE APPLIANCE UNTIL THE PROBLEM IS RECTIFIED. PRESSURE TESTING: ENSURE THE HEATER IS ISOLATED FROM THE GAS SUPPLY BY CLOSING THE MANUAL SHUTOFF VALVE DURING ANY PRESSURE TESTING.
  • Page 16: Installation Flue Spillage Test

    Q u a l i t y & Va l u e I n G a s L o g F i r e s INSTALLATION FLUE SPILLAGE TEST IF THE FLUE IS BLOCKED OR NOT PRODUCING SUFFICIENT DRAW, THE HEATER MUST NOT BE USED UNTIL THE PROBLEM IS RECTIFIED.
  • Page 17: Maintenance

    Replacing Logs The unit should never be used with broken logs. Always turn the gas valve off. And allow the unit to cool before opening door. Remove logs carefully.Logs should only be replaced by an Authorised ILLUSION representative. Note: Improper positioning of logs may create soot build up and carbon monoxide, which will affect heater performance.
  • Page 18 Q u a l i t y & Va l u e I n G a s L o g F i r e s DOOR REMOVAL PROCEDURE REMOVE TOP PANEL OF HEATER AS SHOWN ABOVE SWING BOTH LEFT AND RIGHT HAND SIDE DOORS OPEN. WHILST PRESSING THE DOOR FORWARD, PULL FOUR TOGGLE CLAMP LEVERS TOWARDS THE FRONT OF HEATER AND UNCLIP AS SHOWN REMOVE THE HEATER DOOR MILLENIUM FREESTANDING MANUAL 2014...
  • Page 19: Parts Assembly Exploded View

    Q u a l i t y & Va l u e I n G a s L o g F i r e s PARTS ASSEMBLY EXPLODED VIEW DOOR ASSEMBLY Spare Parts TOP PANEL TOP MOUNTING PANEL FIREBOX Spare parts are available from FAN AIR DUCT your supplier.
  • Page 20: Thermostatically Controlled Fan

    Q u a l i t y & Va l u e I n G a s L o g F i r e s THERMOSTATICALLY CONTROLLED FAN Your new ILLUSION Millenium Gas Space Heater is fitted with a THERMOSTATICALLY CONTROLLED fan.
  • Page 21 Q u a l i t y & Va l u e I n G a s L o g F i r e s OPTIONAL RADIO FREQUENCY PROGRAMMABLE REMOTE CONTROL ILLUSIONs all new OPTIONAL thermostatically controlled remote controller can be operated from anywhere in the house and does not require line of sight.
  • Page 22: Abnormal Operation

    Q u a l i t y & Va l u e I n G a s L o g F i r e s ABNORMAL OPERATION THE FOLLOWING INDICATES SITUATIONS OF ABNORMAL OPERATION OF THE APPLIANCE. WHEN THE HEATER IS OPERATING : 1.
  • Page 23: Troubleshooting

    Q u a l i t y & Va l u e I n G a s L o g F i r e s TROUBLESHOOTING SYMPTOM. •The pilot flame goes out. POSSIBLE CAUSE. •First check that the gas is on, usually with another appliance such as a gas stove.
  • Page 24 Q u a l i t y & Va l u e I n G a s L o g F i r e s ILLUSION Gas Log Fires State Dealer Contact List Head Office 145 Sth Gippsland Hwy Dandenong Sth Victoria Australia 3175 Phone.
  • Page 25 Email: service@Illusionfires.com.au WEB: www.Illusionfires.com.au Illusion Australia Pty. Ltd. reserves the right to alter specifications contained in this publication without notice. Illusion Australia Pty. Ltd. admits no responsibility for printing errors or omissions within this publication. Copyright Illusion Australia Pty. Ltd. 2014...

Table of Contents