Advertisement

Quick Links

EN
ZAC5xPN0x
Ethernet Switches
Operating instructions
Translation of the Original Operating Instruction
Subject to change without notice
Available as PDF version only
Status: 22.01.2020
www.wenglor.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZAC5 PN0 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wenglor ZAC5 PN0 Series

  • Page 1 ZAC5xPN0x Ethernet Switches Operating instructions Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Status: 22.01.2020 www.wenglor.com...
  • Page 2: Table Of Contents

    Table of Contents 1. Proper Use 2. Safety Precautions 3. Approvals and IP Protection 4. Technical Data 4.1. Connection table ZAC50PN0x 4.2. Connection table ZAC51PN01 4.3. Housing Dimensions 4.3.1 ZAC5xxN01 4.3.2 ZAC50xN02 4.4. Complementary Products 5. Application Notes 6. Mounting Instructions 7.
  • Page 3: Proper Use

    A Switch is an active network component which distributes data to the corresponding addressees within a network in a targeted fashion. wenglor switches are fitted optionally with additional Power over Ethernet tech- nology. The power supply is integrated into existing network connection by means of Power over Ethernet. As an addition to Industrial Ethernet, there are several digital inputs and outputs directly on the switch that can be activated or evaluated via the network.
  • Page 4: Technical Data

    4. Technical Data Order number ZAC50PN01 ZAC50PN02 ZAC51PN01 Supply voltage 18...32 V DC 18...32 V DC 18...32 V DC Max. Current Consumption Device * 0.3 A 0.25 A 0.3 A Max. Current Consumption System ** 2.2 A 0.3 A max. PoE Capacity 30 W 25 W –...
  • Page 5: Connection Table Zac50Pn0X

    Socket 3 Socket 3 +24 V DC Socket 4 Socket 4 Socket 4 Suitable Plug: Function www.wenglor.com 0 V DC 0 V DC +24 V DC U System +24 V DC U Digital I/O / Sensor Socket 1 Socket 2...
  • Page 6: Connection Table Zac51Pn01

    RxD (−) Socket 3 Suitable Plug: Socket 2 Socket 2 Function 0 V DC 0 V DC Socket 1 Socket 1 +24 V DC U System +24 V DC U Digital I/O / Sensor Socket 3 Socket 3 www.wenglor.com Technical Data...
  • Page 7: Housing Dimensions

    4.3. Housing Dimensions 4.3.1 ZAC5xxN01 4.3.2 ZAC50xN02 Industrial Communication...
  • Page 8: Complementary Products

    4.4. Complementary Products Connection plug, 7/8", 5-pin Order number: ZAT77NN01 Suitable Plug: Connection socket, 7/8", 5-pin Order number: ZAB78NN01 Suitable Plug: Connecting cable, 7/8", 5-pin Order number: ZAV78R201, Cable length: 2 m Suitable Plug: Technical Data...
  • Page 9 Connecting line, 7/8", 5-pin Order number: ZAS78R601, Cable length: 10 m Suitable Plug: Connector Plug RJ45; 8-pin Order number: ZAT45NN01 Suitable Plug: Connection plug, M12×1; 8-pin Order number: ZAT50NN01 Suitable Plug: Industrial Communication...
  • Page 10 Connecting cable M12×1; 8-pin Order number: ZAV50R201, Cable length: 2 m Order number: ZAV50R501, Cable length: 5 m Suitable Plug: Order number: ZAV50R502, Cable length: 5 m Suitable Plug: Connecting line M12×1, 8-pin Order number: ZAS50R601, Cable length: 10 m Suitable Plug: Connection plug, M12×1, 4-pin Order number: ZAT51NN01...
  • Page 11 Connecting cable M12×1; 4-pin; D-coding Order number: ZAV51R201, Cable length: 2 m Order number: ZAV51R601, Cable length: 10 m Suitable Plug: Order number: ZAV51R202, Cable length: 2 m Order number. ZAV51R602, Cable length: 10 m Suitable Plug: Connection and power supply cables M12×1;...
  • Page 12: Application Notes

    In the event of improper use, the guarantee and liability claim against the manufacturer shall lapse. Information concerning which cables and accessories are approved for installation can be found at www.wenglor.com or are described in this manual. Application Notes...
  • Page 13: System Structure

    7.1. System Structure Industrial Ethernet Digital Digital Digital I/O-Port I/O-Ports I/O-Port Power 7.2. Power Cable Power In Power Out Pin 1 Pin 1 Pin 2 Pin 2 Pin 3 Pin 3 24 V max. 9 A Pin 4 24 V max. 9 A Pin 4 System 24 V max.
  • Page 14: Functional Earth

    (for tightening torque see “Mounting Instructions” on page 12). 7.4. Industrial Ethernet Cable wenglor provides a variety of preassembled industrial Ethernet cables. To ensure cabling as simple and reliable as possible, we recommend using our preassembled Industrial Ethernet cables.
  • Page 15: Industrial Ethernet Cable With Power Over Ethernet

    7.5. Industrial Ethernet Cable with Power over Ethernet To ensure cabling as simple and reliable as possible, we recommend using our preassembled industrial Eth- ernet cables. It is also possible to interconnect two switches with PoE via the 8-pin network cable. The PoE supply should then be switched off on at least one of the two PoE ports (see “Industrial Ethernet Ports Settings”...
  • Page 16: Diagnosis

    7.7. Diagnosis Assignment example: PoE max PoE max www.wenglor.com www.wenglor.com www.wenglor.com Power Power Power Power Power Power Power ZAC50PN01 ZAC50PN02 ZAC51PN01 7.7.1 LED Display PROFINET Device (ZAC50PN0x) PoE max The status displays for the communication are marked on the switch with CS and MS.
  • Page 17: Led Display Profinet Device (Zac51Pn01)

    The LED display on the M12 sockets displays the diagnosis for the corresponding socket. Designation Condition Function Yellow PoE in operation PoE function switched off Yellow flashing Link exists Green Green flashing Communication Designation Condition Function Input UB at Pin 2/4 Yellow IO 0.0/IO 1.0 Output...
  • Page 18 Designation Condition Function Green Link exists Communication via port Green flashing Designation Condition Function Input UB at Pin 2/4 Yellow Output Switching output at UB Pin 2/4 IO 0.0/IO 1.0 Output Short circuit at Pin 2/4 Initial Operation...
  • Page 19: Operation On A Controller

    A detailed description for different controllers and for the installation of the files or for the project planning of the network can be found in the help files of the relevant controller. wenglor offers an example quick guide on starting up a PROFINET device for the Simatic-S7 controller from Siemens and the appropriate software Step 7 Engineering Tool (www.wenglor.com ...
  • Page 20: Detailed Description Of The Modules For Profinet Devices

    7.8.2 Detailed description of the modules for PROFINET devices DAP 1: ZAC50PN01 V1.0 Module ID: 0x00000303 Submodule: 0x00000000 Parameter: Byte Default Value Change- Name Data type Bit offset Bit length Index Length offset value range able Web server BitArea 0: Enabled 1 byte Access Overload...
  • Page 21 DAP 4: ZAC51PN01 V1.0 Module ID: 0x00000303 Submodule: 0x00000000 Parameter: Byte Default Value Change- Name Data type Bit offset Bit length Index Length offset value range able Web server BitArea 0: Enabled 1 byte Access DAP 1/DAP 2/DAP 4 use the module 1 Module 1: 4 bit digital in/out Module ID:...
  • Page 22: Diagnostic Alarms

    7.8.3 Diagnostic alarms The appropriate alarm module should be set up in the controller in the case of an alarm message originating from the switch by short circuit at the ports (hardware interrupt OBs OB40-OB47). If this is not the case, the CPU goes into the STOP mode in the case of an interrupt triggering event.
  • Page 23: Web-Based Configuration

    Diagnostic I/O: Short-circuit after Gnd (going) 0x00000000 Slot 0x0001 Subslot 0x0001 Channel 1: (Port2, Pin2) 2: (Port2, Pin4) 3: (Port4, Pin2) 4: (Port4, Pin4) AlarmSpecifier 0x02, Diagnosis disappears ChannelErrorType 0x0101, (manufacturer-specific) 8. Web-based Configuration The switch is equipped with a web-based setting interface, which works independently of the operating system. You can easily set parameters for the switch using a standard web browser.
  • Page 24 Web-based Configuration...
  • Page 25 To now access the webpage of the switch (in the example ZAC50PN01), the IP address must be entered as described in the address line of the browser. Example: http:\\192.168.100.1 (delivery state) The overview page Device General is not password-protected. If the pages of the device or port settings are accessed, a password prompt appears.
  • Page 26: Overview Page

    8.2. Overview page After the connection is established, the overview page of the switch is displayed. Through the language selection, the website can be changed from English (delivery state) to German, Italian, French or Spanish. Web-based Configuration...
  • Page 27: Device Settings

    8.3. Device settings Network settings: When a switch is not operated on a controller, it is possible to change the network settings. The network set- tings are saved by pressing the “Send” button. To make the changes of the network settings take effect, it is necessary to disconnect the switch briefly from the power supply.
  • Page 28 PoE information (ZAC50PN0x): The switch monitors the current PoE power consumption constantly. The webpage shows the maximum avail- able PoE performance of the switch as well as the currently reserved and outgoing PoE performance. Every PoE device registers in a specific PoE performance class when starting. This performance is then re- served in the switch.
  • Page 29: Industrial Ethernet Ports Settings

    8.4. Industrial Ethernet Ports Settings The Port Settings/Industrial Ethernet Ports page provides an overview of the individual ports of the switch. You can switch between the individual ports using the tab on the uppermost level. The Industrial Ethernet ports contain information on the number of packages received correctly and incorrectly as well as packages sent correctly.
  • Page 30: Digital I/O Ports Settings

    8.5. Digital I/O Ports Settings The switch has 2 ports available with two digital inputs/outputs each. The digital inputs/outputs are configured on the Digital I/O Ports page. Pin 2 and pin 4 can each be configured as input or output. If the pin is configured as output, the pin can be set manually to 0 V or UB.
  • Page 31: Maintenance Instructions

    Respectively valid national waste disposal regulations apply to product disposal. 11. EU Declaration of Conformity The EU declaration of conformity can be found on our website at www.wenglor.com in download area. Industrial Communication...
  • Page 32 This operating manual is only a general description of technical processes whose implementation does not apply to every individual application.

This manual is also suitable for:

Zac51pn01Zac50pn02Zac50pn01

Table of Contents