  • Page 1 Myers D300S EK HD and D300S EK calling panels connecting and programming manual WWW.PARTIZAN.GLOBAL 2020...
  • Page 2: Table Of Contents

    Content: 1. Features............................2 2. Appearance description ........................3 3. Calling panel installation ......................... 4 4. Offline calling panel setup ....................... 5 5. Controller setup access mode ......................5 6. Master password change ........................ 6 7. General unlock password change ....................6 8.
  • Page 3: Features

    1. Features • AHD-M 1.3MP CCTV color CMOS HD camera for D300S EK HD (600TVL color CMOS CCTV camera – for D300S EK). 2. Horizontal viewing angle 130°, vertical 83°. 3. Automatic operation mode (IR LED) day / night, range up to 3 meters. 4.
  • Page 4: Appearance Description

    2. Appearance description 1. Speaker 2. CCTV camera 3. Microphone 4. IR LED + sensor 5. Touch Keyboard 6. Card Reader Area 7. Touch call button 8. Call button "Bell"...
  • Page 5: Calling Panel Installation

    3. Calling panel installation 1. Violet – Calling panel power supply 12V 2. Gray – GND ---------------------------------------- 3. Black – General GND 4. Yellow – Video 5. White – Audio 6. Red – Power from monitor +12V --------------------------------------- 7. Blue – Open Contact (OPEN) 8.
  • Page 6: Offline Calling Panel Setup

    4. Offline calling panel setup The panel comes with a pre-configured control password and general unlock password. Access cards that come with the kit are not added to the controller memory. Control password (master password) is by default: *999999# Unlock password is by default: 123456# 5.
  • Page 7: Master Password Change

    6. Master password change To change the master password, put the controller in setup mode. In this mode, the controller keyboard flashes slowly, the controller waits for a command to be entered. To change the master password: press “0” (the device’s keyboard starts flashing quickly) + “77” + “#” + “XXXXXX”...
  • Page 8: Card Deletion

    Up to 200 cards can be added to the controller's memory. When entering cards, the following order should be followed. If you want to add a card with serial number 5 to the controller, enter “005”, if you want to add a card with serial number 15, enter “015” and so on up to 200. Command: “1”...
  • Page 9: Set Unlock Time

    10. Set unlock time Setting of the unlock time is indicated in seconds from 00 to 99. The setting 02 will be equal to 2 seconds unlock. If 00 is set, the controller will be unlocked by the card and wait for any other card to be read to block.
  • Page 10: Individual Card Pin Code Change

    To enable or disable the lock mode: press “5” (the keypad of the device starts flashing quickly) + “00” (lock is disabled) + “#” to confirm the setting of the lock mode, the controller will emit two short beeps: Command: “5” + “00” + “#” (Lock disabled) Command: “5”...
  • Page 11: Adding Access Cards

    13.1. Adding access cards To add user cards using the master card, press on the calling panel "Bell" call button, and scan master card 3 times in order to add cards, the controller’s keyboard will begin to flash slowly. After that, in turn, scan the cards you want to add. After adding a new card, the controller will signal with two short beeps about the successful addition of the card: If a card has been added before, the controller will signal 4 short beeps: To exit the adding cards mode, scan the add-cards master card to the built-in reader.