PROBLEMS
(SYMPTOMS)
Engine does not start.
Engine does not turn over.
Irregular running of the engine.
Engine stops during operation and the
Engine Protection light does not turn on.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized
Field Service Facility for technical troubleshooting assistance before you proceed.
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
CAUSE
1.
Lack of fuel.
2.
Air mixed in the fuel system.
3.
Clogged fuel filter.
4.
Irregular and faulty fuel supply
(Injector pump trouble).
5.
Glow plug not heated.
6.
Clogged air cleaner.
7.
No compression.
8.
Engine protection light is ON.
1.
Faulty Ignition switch and or
Injector pump solenoid.
2.
Insufficient charging or complete
discharge of the battery.
3.
Improper viscosity of the lubricat-
ing oil.
1.
Air mixed in the fuel system.
2.
Uneven fuel injection (Faulty fuel
injector pump).
3.
Clogged fuel filter.
4.
Defective governor.
5.
Engine itself defective.
1.
Lack of fuel in the fuel tank.
2.
Clogged fuel filter.
3.
Air mixed in the fuel system.
4.
Faulty function of the engine.
CAUTION
E-6
TROUBLE SHOOTING
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas of mis-
adjustment have been checked and the
problem persists, Contact your local
Lincoln Authorized Field Service
Facility.