Fault Diagnosis And Trouble Shooting - LG WD-1050FH Service Manual

Hide thumbs Also See for WD-1050FH:
Table of Contents

Advertisement

8-2.FAULT DIAGNOSIS AND TROUBLE SHOOTING

1. Be careful of electric shock or disconnecting the parts while trouble shooting.
CAUTION
2. First of all, check the connection of each part terminal with wiring diagram.
3. Voltage between each terminal is 220-240V while applying an electric current
(except secondary part of the transformer and sensors)
2
1
PWB ASSY (POWER)
3
All manuals and user guides at all-guides.com
NO POWER
When measuring the voltage of the outlet,
is the voltage 220-240V?
YES
When measuring the voltage of blue
connector of the PWB assy (Power),
is the voltage 220-240V?
YES
Is ③ ③ connector disconnected or
or is the contact bad or cut?
NO
Is wire of the PWB assy(Display)
disconnected?
YES
Replace PWB assy(Display)
18
Check the fuse?
NO
Replace PWB assy
NO
(Power)
Reconnect and repair
YES
connector.
Replace PWB assy(Main)
NO

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wd-8050fh

Table of Contents