4 Set-up
Danger!
Risk of injury due to repeated use of the
carrying handles.
Due to material ageing, the carrying handles
are not designed to be reused during any
subsequent transportation.
▶
Never reuse the carrying handles.
1.
Remove the front casing. (→ Page 11)
Conditions: The unit is too bulky or heavy for transport.
1
2
3
4
6
7
11
10
Disassembling for transport
▶
Remove the side panels (1) to be able to use the carry-
ing handles (2).
▶
Undo the nut (4) on the domestic hot water pump.
▶
Remove the insulating elements (3) and (5).
▶
Undo the nut (9) on the domestic hot water cylinder.
▶
Remove the upper hose from the condensate trap.
▶
Remove the power plug from the cylinder temperature
sensor.
▶
Remove the two power plugs 2 of the domestic hot wa-
ter pump.
▶
Remove the 2 power plugs of the solar PCB (10) from
the unit's main PCB.
▶
Undo the nuts (6) and (8).
▶
Undo the nuts (11) of the solar circuit.
▶
Remove the four screws (7).
▶
When assembling the unit, carry out the steps described
above in reverse.
10
▶
2.
1
5
7
8
7
3.
9
7
4.
5.
Installation and maintenance instructions auroCOMPACT 0020181589_04
Install the cylinder temperature sensor as shown in the
figure.
To transport the unit safely, use the two carrying
handles on the two front feet of the unit.
1
7
5
Turn the carrying handles under the unit so that they
face forwards.
Ensure that the feet are screwed in fully so that the car-
rying handles are held properly.
Always transport the unit as illustrated above.
3