AM IF Alignment (Figures 1 and 3)
Alignment
Step
IF calibratoion
AM Alignment (Figures 1 and 3)
Step
Alignment
1
Tuning range
calibration
2
1
Adjustment of
tracking
2
3
AM SG
Loop antenna
All manuals and user guides at all-guides.com
Frequency
Tuning
of signal
dial
generator
setting
1000 KHz
1000 end
Frequency
Tuning
of signal
dial
generator
setting
530 KHz
Low End
High End
1600 KHz
600 KHz
600 KHz
1400 KHz
1400 KHz
Repeat the above adjustments.
Set
60 cm
CH1
Loop antenna
(Accessory)
Figure 1
13
Adjustment
L6
Obtain sine-wave and
maximum amplitude.
Max.
Adjustment
Obtain sine-wave and
L2
maximum amplitude.
AM-OSC
L1
Max.
AM-ANT
Output meter
J301
Headphone jack
GND
Dummy load
32 Ω