Plumbing should be performed by a qualified Plumber or a pool service technician
where possible.
WARNING: Do Not apply Priming Fluid
to the Clear Cell Housing
All pipe work should be primed with priming fluid before glue is applied, any high pressure
PVC glue will work, make sure both surfaces are well coated before mating the connections
as you will only have a few seconds before the glue bond will take.
Piping from the filter to the Cell should enter the pipe connection closest to the cell head as
per the image below as this is where the water sense probe has been installed during
manufacture. NOTE: When plumbed from the other direction and used with variable speed
pumps having very low flow rates the water probe may not get covered with water causing
the chlorinator to display Priming Cell.
Optional
Return
To Pool
Using
Outlet
1 or 2
PLUMBING
5.