10.3.2 EEPROM abnormal
Indoor Display
Indoor display
Method of
The Data detected by the EEPROM are used to determine MCU
Malfunction
Detection
Malfunction
When the data of EEPROM is error or the EEPROM is damaged
Decision
Conditions
Supposed
Causes
■ Faulty EEPROM
Troubleshooting
* Caution Be sure to turn off power switch before connect or disconnect connector, or parts
damage may be occurred.
E04: Indoor EEPROM error
F12: Outdoor EEPROM error; Outdoor LED1 flash 1 times
■ Faulty EEPROM data
■ Faulty PCB
Replace the indoor or outdoor mainboard.