Owner and Installation Manual For:
QUAD EZ-7000
LOW ENERGY AUTOMATIC SWING
DOOR OPERATOR
PLEASE READ THIS ENTIRE MANUAL AND FOLLOW ALL GUIDELINES TO
ENSURE PROPER INSTALLATION AND SAFETY
PROUDLY DISTRIBUTED BY...
ANSI/UL 991, 325 & CAN/CSA 27 Listed
REV. 1.29.19
- 1 -

Advertisement

loading

Summary of Contents for QUAD EZ-7000

  • Page 1 361-510-4149 Service 361-884-8006 Sales Owner and Installation Manual For: QUAD EZ-7000 LOW ENERGY AUTOMATIC SWING DOOR OPERATOR PLEASE READ THIS ENTIRE MANUAL AND FOLLOW ALL GUIDELINES TO ENSURE PROPER INSTALLATION AND SAFETY PROUDLY DISTRIBUTED BY… ANSI/UL 991, 325 & CAN/CSA 27 Listed REV.
  • Page 2 - 2 -...
  • Page 3: Read This First

    READ THIS FIRST! Quick Start Instructions Caution: When used in a low energy installation, the EZ-7000 operator and associated ES500 control must be installed and adjusted in accordance with ANSI 156.19. Warning: The ES500 control must remain connected to the operator at all times.
  • Page 4 - 4 -...
  • Page 5 CAUTION An improperly installed and/or adjusted Automatic Door can cause injury and equipment damage. Door must be installed and adjusted as described in this Owner’s Manual by a certified professional. All required safety devices must be in place and operational. Door must be inspected DAILY.
  • Page 6: Warranty

    There is no expressed or implied warranty by Quad Systems, LLC except as specifically stated above. Quad Systems, LLC shall not be liable for special or consequential damage, nor for claims of any third party against the buyer. NOTE: Quad Systems, LLC units are identified by serialized numbers (stamps or stickers) and recorded by sales purchase order numbers, date sold, date made and date tested.
  • Page 7 - 7 -...
  • Page 8 - 8 -...
  • Page 9 WARNING: The EZ-7000 may be used for Residential or Commercial interior doors only with widths up to 48" (1220 mm) and a maximum weight of 200 lb. (91 kg). The operator can open the door up to an opening angle of 110°...
  • Page 10 Step Two-Mounting Operator-Controller • Move square nuts provided in header slots to pre-marked positions. • Lift unit into header and secure with the 4 bolts provided making sure output shaft is at center of opening. WARNING: The closing speed control is built into the Controller. DO NOT wind or rotate the motor until the Controller is installed and plugged in or serious damage could be inflicted on the Controller as well as the installer.
  • Page 11 Installing Power Arm and Rod • Prepare Power Arm and Rod as per drawings and charts. - 11 -...
  • Page 12 - 12 -...
  • Page 13 ES-500 Swing Control Installation WARNING: When used in a low energy installation, the EZ-7000 operator and associated ES500 control must be installed and adjusted in accordance with ANSI 156.19 documentation. WARNING: The ES500 control must remain connected to the operator at all times. Never leave the operator without a control connected, as the closing speed will be uncontrolled and may cause severe damage to the operator or door.
  • Page 14 Important: Be sure to save any changes you make before leaving the jobsite! Changes are not stored in the ES500 control’s permanent memory until you save them. To save your parameters, with the door in normal operation, press and hold the SET button until the display winks dS (data Saved).
  • Page 15 The control directly supports the use of automatic locks of either the mortise or magnetic type. An optional lock harness must be obtained from Quad Systems. If a lock is to be used, wire it to the lock harness as shown in the diagram. Typically, the normally closed relay contact is used with magnetic locks and the normally open contact for mortise strikes.
  • Page 16 1.6 Display Codes During normal operation, the ES500 control displays its current status via the display as follows: Id Idle, awaiting open command SA SAfety device active, door prohibited from opening OS Opening door at Open Speed OC Opening door at Open Check speed HO Holding Open OP Manual Opening detected (with PG turned off) CL CLosing door, with speed set by close speed adjustment...
  • Page 17 For paired operation, d3 must be set the same as d1 (see notes on page 10). LC Latch Check delay. This delay begins when the door reduces speed to latch check. It should be set to ensure that the door is fully closed before the display switches from LC to Id. It prevents the safety devices, if any, from being re-enabled too early during the closing sequence.
  • Page 18 EZ-7000 Power Consumption The measured currents and power consumptions for the EZ-7000 operator are as follows: -Idle, door closed: 0.066 amperes, 8 watts -Opening, operator only (no door attached), peak measurement: 0.46 amperes, 56 watts -Holding open: 0.265 amperes, 32 watts...
  • Page 19 - 19 -...
  • Page 20 - 20 -...
  • Page 21 Lock with No Transformer (not recommended) Lock with Transformer (recommended) - 21 -...
  • Page 22 - 22 -...
  • Page 23 BEA Technical Support East Region 866.836.1863 West Region 888.419.2564 - 23 -...
  • Page 24 Optex Technical Support 800-966-7839 - 24 -...
  • Page 25 904C Optex Technical Support 800-966-7839 - 25 -...
  • Page 26 C4160-2, C4190, or C7160-3 controls. An adapter harness would be required to allow the EZ-7000 to plug into the Horton control. The harness would have the proper connectors on each end and would also include the brown wire for the open check micro-switch, which Horton's C7160-3 control requires (Quad Systems ES-500 control does NOT require this connection, so it is not present in the current operator wiring harness).
  • Page 27 Q. I am using the operator in a high energy mode. How can I acquire support for a safety beam per ANSI 156.10? A. Although Quad Systems does not recommend the use of this operator and/or control in a high energy mode, this feature is supported beginning in Versions 1.02/1.03. An auxiliary harness (Close Monitor harness, (part number 600-0008-01) will be required.