Available settings are 1-3 with a factory
default of 3. Refer to the THERMOSTAT
Mode section for additional details on
flame modulation in THERMOSTAT
mode.
While in MANUAL ON, THERMOSTAT
ON, or PROGRAM ON modes, touch
the FLAME Zone to enter Flame-A Ad-
justment, then press the UP or DOWN
buttons to raise and lower the fl ame;
press the MODE/SET Button or wait for
15 seconds to accept the new setting.
LCD Display: When setting the Flame-A
height, the Flame-A icon, and Flame-A
setting number will fl ash in the FLAME
Zone.
Child-Lock Operation
Child-Lock operation prevents any user
input to the transmitter. No mode of op-
eration or feature may be adjusted when
Child-Lock is activated. All automatic
functions (thermostat, program, etc.) will
continue normally.
To activate or deactivate the Child-Lock
feature, press and hold the MODE/SET
and DOWN Buttons simultaneously for
5 seconds.
LCD Displays:
• When activated, the LOCK icon will ap-
pear in the MODE Zone.
• If any touch-zone or button is pressed
when activated, the LCD backlight will
illuminate and the LOCK icon will fl ash
for 5 seconds in the MODE Zone.
Room Temperature Limit
The Room Temperature Limit Shut-
down feature will operate in MANUAL
ON, THERMOSTAT ON mode, and
PROGRAM ON modes. If the room tem-
perature reaches 95 deg. F or greater,
the transmitter will automatically change
to MANUAL OFF mode and send a
MANUAL OFF command to the control
module. If the user turns the control
back ON and the room temperature is
still 95F or greater, the transmitter will
switch to back manual OFF and send
another OFF command the next time
the transmitter reads & updates the room
temperature (2-minute update interval).
900719-00B
OPERATION
Continued
LEARN PROCESS (PAIRING THE
REMOTE TO THE CONTROL
MODULE)
NOTE: The transmitter must be in the "OFF" or
"THERMO OFF" in order to allow the remote
to pair with the control module.
To pair the remote transmitter to the control
module, press the learn switch and release.
There should be an audible beep indicating
the module is ready to accept a transmitter
code. Next, press the mode/set button twice
on the transmitter within 60 seconds to send
a signal (the "MODE/SET" button must be
pressed once to activate the screen [lights up]
and then a second time for the remote and
module to pair). If the signal is received, the
module should beep indicating the signal was
received. NOTE: Module will remain "Open"
and ready to accept a signal for 60 seconds
after the learn switch is pressed.
The control module will learn up to 3 different
transmitter security codes (only one may be
a thermostat style).
Press and hold in the learn switch in for 6
seconds to clear all transmitter security codes
retained in memory. After releasing the switch,
three series of beeps will be heard. This
serves as proof that the transmitter's secu-
rity codes have been cleared from memory.
Repeat learn process as needed.
ON/OFF Switch turns the burner on
and off
Hi (Off) / Low (On) Switch controls the
main burner fl ame height
Momentary Switch (Learn) is for pro-
gramming the remote (see instructions
above).
SuperiorFireplaces.us.com
Unit Mounted Switches
Burner
Hi-Lo
Learn
27