Download Print this page

Graco 244342 Instructions-Parts List page 3

Electronic fluid commander meter pulse converter

Advertisement

Mount the Converter
Mount the converter (Fig.1) to the wall or other secure
surface using the mounting holes. Do not let the unit
hang unsecured.
CAUTION
Do not mount the pulse converter near a heat source.
Connect the Converter
NOTE: When connecting the converter to the pulse
meter, use only the connecting cables permanently
attached to each unit. Do not use extension cables to
lengthen the distance between the pulse meter and the
converter. A distance greater than 24 inches (61
cm) between the units can degrade the signal.
Female connector
to Pulse Meter
(Graco part number
215474)
Fig. 1
Installation
Mounting holes
Technical Data
Pulse Converter Technical Data
Category
Operating temperature
Max. VDC
Wiring Gauge Required
Wiring Polarity
g
y
1. Turn off the Electronic Fluid Commander and
unplug it.
2. Connect the converter to the pulse meter first
using the connector with two female sockets.
3. Connect the converter to the Electronic Fluid
Commander (EFC) using the remaining male
connector.
4. Plug in the Electronic Fluid Commander and turn
on the switch at the rear of the control.
Note: During power--up, all display segments must
show and all stations and dispense lights must light
steadily for 3 to 4 seconds. When the display shows
four dashes, enter your security code. (Refer to the
Electronic Fluid Commander manual for details).
TI0708B
Data
--4_F (--20_C) to 176_F (80_C)
15 VDC at 20mA
18 AWG 2 wire / 90V
Red = + (positive)
Black = -- (negative)
Male connector
to EFC
Mounting holes
309276