Exalt rc06020 FCC Installation And Management Manual

Exalt rc06020 FCC Installation And Management Manual

Digital microwave radios
Table of Contents

Advertisement

Quick Links

Models:
208871-001
2013-11-18
Digital Microwave Radios Installation
rc06020 FCC
rc07020 ITU/ETSI
rc08020 ITU/ETSI
rc11020 FCC
rc11020 ITU/ETSI
rc13020 ITU/ETSI
rc15020 FCC
rc15020 ITU/ETSI
ExtendAir
and Management Guide
rc18020 ITU/ETSI
rc23020 ITU/ETSI
rc38020 ITU/ETSI
®
G2™
rc18020 FCC
rc23020 FCC
rc38020 FCC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the rc06020 FCC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Exalt rc06020 FCC

  • Page 1 ® ExtendAir G2™ Digital Microwave Radios Installation and Management Guide Models: rc06020 FCC rc18020 FCC rc07020 ITU/ETSI rc18020 ITU/ETSI rc08020 ITU/ETSI rc23020 FCC rc11020 FCC rc23020 ITU/ETSI rc11020 ITU/ETSI rc38020 FCC rc13020 ITU/ETSI rc38020 ITU/ETSI rc15020 FCC rc15020 ITU/ETSI 208871-001...
  • Page 2: Open-Source License Information

    Agreement with Exalt Communications, Inc. and/or its subsidiaries, certain Third Party Software may be provided with and as part of the Exalt products provided to you, and any such Third Party Software files provided are governed by the terms of their separate Third Party Licenses, which licenses give...
  • Page 3: Table Of Contents

    Exalt Graphical User Interface (GUI) ........
  • Page 4 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Log In ............. 26 Login Privileges .
  • Page 5 Canada ............. . 101 Exalt Limited Hardware Warranty Software License and RMA Procedures Agreement . . 102 Copyright Notices .
  • Page 6: List Of Figures

    Figure 10: Initiating the browser connection ..................26 Figure 11: Browser Login screen ......................26 Figure 12: Radio Information page ...................... 27 Figure 13: Exalt GUI window description ................... 29 Figure 14: Summary status information ....................30 Figure 15: Radio Information page ...................... 31 Figure 16: Administration Settings page ....................
  • Page 7 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios List of Tables Table 1: Supported configurations ......................2 Table 2: Factory default settings ......................8 Table 3: Connectors ..........................15 Table 4: LED indicators ........................16 Table 5: Default login information .......................27 Table 6: Alarm status indicators ......................52 Table 7: Supported direct-mount antennas ...................87...
  • Page 8: About This Document

    ExtendAir G2 Digital Microwave Radios About this Document This manual provides a complete description of the ExtendAir G2 family of Exalt Digital Microwave Radios and related software. This manual provides planners, engineers, installers, system administrators, and technicians general and specific information related to the planning, installation, operation, management, and maintenance of these devices.
  • Page 9: Introduction

    ExtendAir G2 Digital Microwave Radios Introduction Exalt Communications, Inc. thanks you for your purchase. Our goal is to build the highest quality, highest reliability digital microwave radio products. This commitment to quality and reliability extends to our employees and partners alike. We appreciate any comments on how we can improve our products, as well as your sales and Customer Care experience.
  • Page 10: Table 1 Supported Configurations

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios The ExtendAir G2 model number scheme uses the first two digits to define the general frequency band (in GHz) and the last three digits to define the connector and base configuration.
  • Page 11: Basic Features

    Please consult your local regulatory organization(s) to determine usage requirements. In almost all cases, the product itself must be authorized for use in your country. Either Exalt or Exalt’s agent must have applied for certification or authorization to allow the sale and deployment of the system within the country.
  • Page 12: Figure 2 Cabling And Surge Suppression

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Figure 2 Cabling and surge suppression The ExtendAir G2 radios provide connections for up to two Gigabit Ethernet data communication interfaces, and are powered by a combined Power/Ethernet cable, and associated power injector. The power injector provides 48VDC to the unit.
  • Page 13: Preinstallation Tasks

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Preinstallation Tasks This section describes the steps necessary to prepare a site for the installation of the Exalt Digital Microwave Radio. Link Engineering and Site Planning Design all terrestrial wireless links prior to purchase and installation. Generally, professional wireless engineering personnel are engaged to determine the viability and requirements for a well-engineered link to meet the users’...
  • Page 14: Shipping Box Contents

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Exalt recommends using the Exalt GUI for radio configuration. This interface requires a computer with an Ethernet port and web browser software, such as Microsoft Internet Explorer 5.0 or above. See...
  • Page 15: Rf Output Power Setting

    – Configure IP settings for configuration and management – Configure passwords and security modes – Become familiar with the configuration and management interfaces through the Exalt GUI interface – Configure radio parameters – Set transmitter output power to engineered or allowed level (see...
  • Page 16: Critical Configuration Considerations

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Critical Configuration Considerations The ExtendAir G2 radios are very dynamic, allowing the installer to optimize and control the performance of the radio system for the intended application. The following parameters must be carefully determined during the link engineering phase: •...
  • Page 17: Radio Reset

    Exalt’s VLAN communications implementation adheres to the IEEE standard 802.1q. In most cases, an Exalt radio acting as a Layer 2 bridge between two locations is only required to pass traffic with VLAN tagging. Without additional configuration, all Exalt radios support frame sizes in excess of 1900 bytes, which currently supports all defined VLAN packet sizes.
  • Page 18: Simple Network Management Protocol (Snmp)

    ExtendAir G2 Digital Microwave Radios Note: If an application only requires the transparent passing of VLAN traffic, disable the VLAN function. Some situations require Exalt radios to act upon VLAN traffic and perform any or all of the following functions: •...
  • Page 19: System Installation And Initiation Process

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Installation and Initiation Process The tasks required for radio installation and initiation are outlined in the following figure. Transmission System Tasks Radio Preparation Tasks Read This Path & Site...
  • Page 20: Record Keeping

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Record Keeping After installation, record the following items for ongoing maintenance and future troubleshooting. Keep a record for each end of the radio link and store a copy of these records at the radio location, at the opposite end radio location, and a central record storage location.
  • Page 21: Installation

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Installation This section presents all tasks required to install the Exalt Digital Microwave Radio. Mechanical Configuration and Mounting The ExtendAir G2 radios are environmentally sealed units intended for deployment outdoors. The device must be deployed within an ambient temperature range as specified, and with non-restrictive airflow around the chassis.
  • Page 22: Radio Ports And Indicators

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Secure the mounting clips on the four corners of the radio chassis to the mating clips on the antenna, one at a time. Note: Clip two opposite corners first, then clip the remaining two corners.
  • Page 23: Connector Overview

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios GROUND ETH2 RSL/RESET POWER/ETH1 Figure 6 ExtendAir G2 connectors Connector Overview The primary user interfaces are shown in Figure 6. Table 3 provides details of the front panel connectors. Detailed pin structures for each connector are in Interface Connections.
  • Page 24: Led Indicators

    Note: All injectors used with this product must be 802.3at compliant. Read this section completely before applying power. As an alternative to an off-the-shelf 802.3at injector, Exalt provides modular PoE solutions, including a multi-injector rack mount solution, that can properly power the ExtendAir G2 radio. These modular injectors (models A300505, A300501, and A300502) provide proper power to the radio, but the RESET button on these models does not reset the ExtendAir G2 radio.
  • Page 25: Terminating The Rf Connection

    Do not apply power using a live RJ45 connector. Connect all RJ45 connectors first, and then apply power. Exalt strongly recommends that the power supplies be fused or on a separate breaker to ensure against over-voltage and/or over-current situations and to provide some form of protection to the radio electronics and other devices connected to the same supply.
  • Page 26: Diplexer (Channel Plan) Configuration

    CAUTION! Removal of the diplexer cover requires special care. The instructions in this section must be followed precisely to maintain performance and weatherproof operation. Exalt Limited Hardware Warranty Software License and RMA Procedures Agreement may be void if damage to the radio occurs as a result of improper installation.
  • Page 27: Figure 8 Diplexer Configuration Labels

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Figure 8 Diplexer configuration labels • The Port label indicates the frequency range of the corresponding port (on the underside of the diplexer). One side is Tx and the other is Rx, depending on how it mounts to the radio.
  • Page 28 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Note that the gasket on the center nozzle of the RF section is a tight fit, so this will take some effort. CAUTION! Do not place any object between the seams of the chassis to assist with separation–this will damage the outer diameter gasket.
  • Page 29: Antenna/Transmission System

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Replace the cover and secure the four (4) Hex screws on the radio chassis, CAUTION! Do not pinch the rubber O-ring gasket. Place new labeling on the radio chassis, as necessary.
  • Page 30: Transmission Line From Antenna To Radio (Remote Mount)

    Refer to the Exalt white paper, Antenna Alignment, for more information on antenna alignment techniques.
  • Page 31: Antenna Alignment

    • Audio alignment buzzer Enable the audio alignment buzzer through the Exalt GUI. When enabled, the radio enclosure emits a sound. The pitch rises when higher (better) levels of RSL are achieved. Align the antennas until the highest pitch is accomplished. The tone is continuous when the two ends of the radio system are in communication.
  • Page 32: Configuration And Management

    None Telnet into the Command Line Interface (CLI) Use a Telnet connection to access the CLI in the Exalt Digital Microwave Radios. Use the CLI to set key parameters on the system. Connect to the Radio in a Telnet Session Make the Telnet connection to the radio through the Ethernet port.
  • Page 33: Exalt Graphical User Interface (Gui)

    If the radio supports DHCP and DHCP is enabled (see Ethernet Interface Configuration Page), which is the default setting for a radio shipped from Exalt (for the models with this feature), and your computer’s Ethernet port is set for DHCP addressing, the radio will configure your computer to 10.0.0.3 or 10.0.0.4, and no manual IP configuration is required.
  • Page 34: Make Connections

    Microsoft Internet Explorer is the recommended browser. Netscape, Mozilla, and Firefox are also supported. If there are issues with your browser, please report it to Exalt Customer Care. You may be required to use a different browser to immediately overcome issues.
  • Page 35: Quick Start

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios • User (user) – assigned limited, view-only permissions with no edit or configuration rights The default login names and passwords are as follows: Table 5 Default login information Privilege level...
  • Page 36: Navigating The Gui

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios – The radio IP address is listed on the Administration Settings Page. • Verify that the two terminals are opposite channel plans. – The product label indicates the frequency band and sub-band of the shipped configuration, such as ending in 1H or H1 (for Band 1, Hi Tx).
  • Page 37: Summary Status Section

    The Summary Status Section allows the Exalt GUI to be a rudimentary management system. Minimize the browser window to display just the top bar or the top bar and radio information, and open several browsers on the desktop.
  • Page 38: Navigation Panel

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Figure 14 Summary status information Navigation Panel In the navigation panel, pages with sub-pages have a plus (+) to the left of the page link. Click the plus sign or page name title to view sub-page titles. The pages can be collapsed to hide the sub-pages when a minus (–) sign appears to the left of the page link.
  • Page 39: Radio Information Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Radio Information Page This page provides general information about the local radio terminal. This information is helpful for troubleshooting and for record keeping. Figure 15 Radio Information page 208871-001 2013-11-18...
  • Page 40: Administration Settings Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Administration Settings Page This page allows contains general parameters for the radio system. The Current Value column lists entries actual settings. Desired changes are entered in the New Value column.
  • Page 41 • Enter the license key provided by Exalt to access extended features or diagnostic capabilities. Click Update to accept the changes and enable the new features. License keys are issued by radio serial number, so ensure that the license key used was issued for this particular radio.
  • Page 42: Ntp And Time Zones Configurations Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios NTP and Time Zones Configurations Page Use this page to set the Network Time Protocol (NTP), number of NTP client(s), and local time zone. Figure 17 NTP and Time Zones Configurations page...
  • Page 43: Simple Network Management Protocol (Snmp) Configuration

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Simple Network Management Protocol (SNMP) Configuration This page allows the enabling and disabling of the Simple Network Management Protocol (SNMP) functions. Use SNMP to manage networked devices and execute the following functions: •...
  • Page 44: Snmp V1/V2C/V3 Support Options

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios SNMP v1/v2c/v3 Support Options Enable the SNMPv1/v2c options to allow entering read and read/write community strings. Note: Users are encouraged to avoid enabling SNMPv1/V2c support due to known security loopholes in these protocols.
  • Page 45 ExtendAir G2 Digital Microwave Radios • Local/Remote Link Status Trap: This trap is sent when Link is in errored state (equivalent to the Link LED on the radio front panel or the Link status bar in the upper-left of the Exalt GUI window). •...
  • Page 46: File Transfer Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios File Transfer Page This page allows the administrator to upload and download files to and from the radio. Two types of files can be uploaded: configuration, and radio firmware. When uploading Configuration Files, current configuration parameters are immediately overwritten, and the unit may reboot if configuration changes require a reboot.
  • Page 47: Figure 21 File Transfer Page-Download File Link

    File download and upload is useful when configuring several radios with similar settings. A copy of the configuration file can also help restore radio settings. In addition, a copy of the Exalt default configuration file is helpful to restore the radio to factory settings.
  • Page 48 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios The following parameters can match at both ends of the link: • Link Name • Link Security Key (although each link should be different) • Admin and User passwords •...
  • Page 49: File Activation Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios File Activation Page Use this page to move stored or uploaded files for use on the radio. The page indicates which file is currently in use, and which file is available for use. Click the Swap button to place the file in the Alternative File column into the active state and move the file in the Current File column to the Alternative File column.
  • Page 50: System Configuration Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Configuration Page This page contains several critical system parameters. Figure 23 System Configuration page–ExtendAir Most entries on this page are self-explanatory. The following lists unique or important parameters. •...
  • Page 51 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Note: The link may be lost and unrecoverable through GUI control. If the link is lost due to reduction of Radio Transmit Power, travel to the radio location(s) may be required to reset the value.
  • Page 52 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Note: Changing Mode will temporarily interrupt traffic. The Mode setting must match at each end. Adjust the far-end radio first, and then the near-end radio. Changing Mode changes the radio’s threshold, carrier-to-interference ratio, and also may have impact on the Radio Transmit Power.
  • Page 53: Ethernet Interface Configuration Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Ethernet Interface Configuration Page This page allows the administrator to set the muting, alarm, and duplex settings of both the Ethernet connection and allows determination of the management information for in-band (carried over the air and available from both Ethernet connectors on either end of the link) or out-of-band (not carried over the air and only available from the local PoE connector).
  • Page 54 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios • Set the Ethernet ports on the radio and connected equipment to 100/full-duplex for best performance. If the Ethernet ports are set to auto-negotiation, poor throughput performance may be a result, as well as intermittent disconnections of the Ethernet connection.
  • Page 55: Vlan Configuration Page

    VLAN Configuration Page VLAN is disabled as the default setting for Exalt radios. The Exalt radios still pass VLAN and non- VLAN traffic across the link, but do not examine the VLAN traffic or act upon it. Enable VLAN using the Exalt GUI for expanded VLAN support.
  • Page 56 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios • Enabled & Pass Untagged: To pass desired VLANs across the radio, they must be listed in the lower tables per their respective interfaces. All other VLAN traffic is not passed across the link, and untagged traffic is passed across the link with no changes.
  • Page 57: Ethernet Rate Limiting Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Ethernet Rate Limiting Page This page enables radio Ethernet port rate limiting. Enable this to limit the output information rate to at or below downstream networking equipment capabilities. The rate is in Mbps or kbps, as specified.
  • Page 58: Ethernet Learning Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Ethernet Learning Page This page allows enabling or disabling Media Access Control (MAC) learning. This is a universal setting for all Ethernet interfaces. Figure 27 Ethernet Learning page Some network configurations may broadcast the same MAC Source address on multiple interfaces, and if learning is enabled, data transport errors can result.
  • Page 59: Syslog Configuration Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Syslog Configuration Page Syslog serves as a remote means to receive event log messages (configuration and alarm state changes) for network management and/or record keeping. Figure 28 Syslog Configuration page To enable the syslog, check the Remote host logging option and input the IP address for the remote host.
  • Page 60: Alarms Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Alarms Page This page provides an easy-to-read summary of the alarm status of both local and remote radios. The colors on this page reflect the color of the alarms displayed on the radio front panel. However, additional detail displays on this page to aid in quick assessment of issues and status.
  • Page 61 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Table 6 Alarm status indicators (Continued) Label Status Temperature • Green Solid = Normal temperature range • Yellow Solid = Exceeding normal temperature range The Temperature alarm monitors the internal temperature of the unit based on specific points inside the radio chassis.
  • Page 62: Performance Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Performance Page This page provides statistical information about the performance of the system in relation to the integrity of the user data and the RF link. Figure 30 Radio Performance page •...
  • Page 63 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios design goals, and compare actual performance to these expectations to determine if any improvements are necessary or if other problems may be causing excessive ES. Note: Unavailable Seconds do not register as ES. In other words, the ES counter counts all seconds that are errored NOT INCLUDING the seconds that were classified as unavailable.
  • Page 64 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Note: Resetting statistics from one end also resets the statistics for the same radio at the opposite end. That is, if the Local statistics are reset, logging into the remote end shows the Remote statistics on that end (which is the local radio in the first condition) as being reset at the same time.
  • Page 65: Ethernet Performance Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Ethernet Performance Page This page displays statistics related to Ethernet traffic to assist with troubleshooting and for general performance monitoring. These statistics are aligned with the Remote Network Monitoring (RMON) convention, RFC 2819 (http://tools.ietf.org/html/rfc2819).
  • Page 66 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios • Fragments • Jabbers • Collisions 208871-001 2013-11-18...
  • Page 67: Event Log Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Event Log Page Use this page to review a list of the events logged by the radio. The following items are listed in the event log: • Alarms • Alarms clearing (normal) •...
  • Page 68: User Throughput Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios User Throughput Page This page illustrates the user throughput of the radio, as configured. Figure 33 User Throughput page Click the help icon ( ) to go to the page on how this information is determined (Figure 34).
  • Page 69: Figure 34 User Throughput Help Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Figure 34 User Throughput Help page 208871-001 2013-11-18...
  • Page 70: Diagnostic Charts Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Diagnostic Charts Page Use this page as an aid in troubleshooting. This page illustrates the historical (and current) performance for three parameters: RSL, Radio Temperature, and BER. The horizontal scale illustrates 120 points of time measurement and is synchronized on all three graphs.
  • Page 71 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios interference, atmospheric changes, transmission system issues (such as problems with cables, connectors, or antennas), or possibly radio hardware problems. 208871-001 2013-11-18...
  • Page 72: Ethernet Utilization Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Ethernet Utilization Page This page shows a chart for each Ethernet interface to illustrate inbound and outbound packet utilization. This is shown as a percentage of the interface configuration (that is, if your interface is set for 100BaseT, then 100% represents 100Mbps.
  • Page 73: Reboot Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Reboot Page Use this page to reboot the radio. The function may never be required, but can be used in emergencies. All configurations that require a reboot automatically reboot on administrator confirmation.
  • Page 74: Manual Page

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Manual Page The manual (this document or the version that matches the installed firmware) is available within the GUI. Adobe Acrobat Reader 5.5 or higher is required (go to www.adobe.com to download Acrobat Reader).
  • Page 75: Specifications

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Specifications This section presents specifications for the ExtendAir G2 digital microwave radios. Physical Specifications Physical Configuration Outdoor Unit (ODU) Dimensions (HxWxD) 9.4 x 9.4 x 4.5 inches / 23.9 x 23.9 x 11.4 cm Weight 9.5 lbs/4.3 kg...
  • Page 76 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Full-Duplex User Capacity (Max system layer 1/Max Ethernet layer 2 Mbps QPSK 16QAM 32QAM 64QAM 128QAM 256QAM 3.5MHz 13/10 16/13 20/16 – – 5MHz 20/16 25/20 30/24 35/28 – 7MHz...
  • Page 77: System Specifications, 6Ghz Lower Fcc Band

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 6GHz Lower FCC Band Frequency Band 5.925–6.425GHz Output Power (at full power) +26dBm, QPSK +24dBm 16QAM +23dBm 32QAM +21dBm 64QAM +21dBm 128QAM +20dBm 256QAM Output Power (at minimum power)
  • Page 78: System Specifications, 6Ghz Upper Fcc Band

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 6GHz Upper FCC Band Frequency Band 6.425–6.875GHz Output Power (at full power) +26dBm, QPSK +24dBm 16QAM +23dBm 32QAM +21dBm 64QAM +21dBm 128QAM +20dBm 256QAM Output Power (at minimum power)
  • Page 79: System Specifications, 11Ghz Fcc Band

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 11GHz FCC Band Frequency Band 10700–11700GHz Output Power (at full power) +26dBm, QPSK +24dBm 16QAM +23dBm 32QAM +21dBm 64QAM +21dBm 128QAM +20dBm 256QAM Output Power (at minimum power)
  • Page 80: System Specifications, 15Ghz Fcc Band

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 15GHz FCC Band Frequency Band 14.500–15.350GHz Output Power (at full power) +26dBm, QPSK +24dBm 16QAM +23dBm 32QAM +21dBm 64QAM +21dBm 128QAM +20dBm 256QAM Output Power (at minimum power)
  • Page 81: System Specifications, 18Ghz Fcc Band

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 18GHz FCC Band Frequency Band 17.700–19.700GHz Output Power (at full power) +23dBm, QPSK +21dBm 16QAM +20dBm 32QAM +18dBm 64QAM +18dBm 128QAM +17dBm 256QAM Output Power (at minimum power)
  • Page 82: System Specifications, 23Ghz Fcc Band

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 23GHz FCC Band Frequency Band 21.200–23.600GHz Output Power (at full power) +22dBm, QPSK +20dBm 16QAM +19dBm 32QAM +17dBm 64QAM +17dBm 128QAM +16dBm 256QAM Output Power (at minimum power)
  • Page 83: System Specifications, 38Ghz Fcc Band

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 38GHz FCC Band Frequency Band 38.600–40.000GHz Output Power (at full power) +21dBm, QPSK +19dBm 16QAM +18dBm 32QAM +16dBm 64QAM +16dBm 128QAM +15dBm 256QAM Output Power (at minimum power)
  • Page 84: System Specifications, 7Ghz Itu/Etsi

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 7GHz ITU/ETSI Frequency Band 7.125–7.90GHz Output Power (at full power) +26dBm, QPSK +24dBm 16QAM +23dBm 32QAM +21dBm 64QAM +21dBm 128QAM +20dBm 256QAM Output Power (at minimum power) 0dBm...
  • Page 85 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios RF Diplexers TR 154 MHz Lo/Hi TR 168 MHz Lo/Hi Band 1: 7.582–7.638 GHz/7.428–7.484 GHz Band 1: 7.611–7.667 GHz/7.443–7.499 GHz Band 2: 7.624–7.680 GHz/7.470–7.526 GHz Band 2: 7.653–7.709 GHz/7.485–7.541 GHz Band 3: 7.666–7.722 GHz/7.512–7.568 GHz...
  • Page 86: System Specifications, 8Ghz Itu/Etsi

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 8GHz ITU/ETSI Frequency Band 7.90–8.50GHz Output Power (at full power) +26dBm, QPSK +24dBm 16QAM +23dBm 32QAM +21dBm 64QAM +21dBm 128QAM +20dBm 256QAM Output Power (at minimum power) 0dBm...
  • Page 87: System Specifications, 11Ghz Itu/Etsi

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 11GHz ITU/ETSI Frequency Band 10.70–11.70GHz Output Power (at full power) +26dBm, QPSK +24dBm 16QAM +23dBm 32QAM +21dBm 64QAM +21dBm 128QAM +20dBm 256QAM Output Power (at minimum power) 0dBm...
  • Page 88: System Specifications, 13Ghz Itu/Etsi

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 13GHz ITU/ETSI Frequency Band 12.75–13.25GHz Output Power (at full power) +26dBm, QPSK +24dBm 16QAM +23dBm 32QAM +21dBm 64QAM +21dBm 128QAM +20dBm 256QAM Output Power (at minimum power) 0dBm...
  • Page 89: System Specifications, 15Ghz Itu/Etsi

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 15GHz ITU/ETSI Frequency Band 14.400–15.350GHz Output Power (at full power) +26dBm, QPSK +24dBm 16QAM +23dBm 32QAM +21dBm 64QAM +21dBm 128QAM +20dBm 256QAM Output Power (at minimum power) 0dBm...
  • Page 90: System Specifications, 18Ghz Itu/Etsi

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 18GHz ITU/ETSI Frequency Band 17.70–19.70GHz Output Power (at full power) +23dBm, QPSK +21dBm 16QAM +20dBm 32QAM +18dBm 64QAM +18dBm 128QAM +17dBm 256QAM Output Power (at minimum power) 0dBm...
  • Page 91: System Specifications, 23Ghz Itu/Etsi

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 23GHz ITU/ETSI Frequency Band 21.200–23.610GHz Output Power (at full power) +22dBm, QPSK +20dBm 16QAM +19dBm 32QAM +17dBm 64QAM +17dBm 128QAM +16dBm 256QAM Output Power (at minimum power) 0dBm...
  • Page 92: System Specifications, 38Ghz Itu/Etsi

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios System Specifications, 38GHz ITU/ETSI Frequency Band 37.00–39.50GHz Output Power (at full power) +21dBm, QPSK +19dBm 16QAM +18dBm 32QAM +16dBm 64QAM +16dBm 128QAM +15dBm 256QAM Output Power (at minimum power) 0dBm...
  • Page 93: Interfaces

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Interfaces Connector Waveguide flange: 7GHz and 8GHz:WR112/UBR84 11GHz and 13GHz: WR75/UBR120 15GHz: WR62/UBR140 18GHz: WR42/UBR220 23GHz: WR42/UBR220 38GHz: 0.219" diameter Impedance 50 Ohms Ethernet Connectors RJ-45, female, auto-MDIX Interface Speed...
  • Page 94: Interface Connections

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Interface Connections This section provides the pin number assignment and wiring information for the connectors on the ExtendAir G2 radios. All connectors are shown as viewed from the radio front panel.
  • Page 95: Antennas

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Antennas Table 7 lists direct-mount antennas for the ExtendAir G2 models. Any standard waveguide-feed antenna can be used with a flexible or rigid waveguide between the radio and the antenna. Ensure that the waveguide flange type of the antenna and the radio match.
  • Page 96: Troubleshooting

    (see Diagnostic Charts Page). Contact Exalt Customer Care for further assistance with issues with your Exalt radio and with suggestions on how the radio and documentation can be improved. General Practices Troubleshooting a microwave radio link can be a complex task. Approach troubleshooting as a process of elimination, and first determine which portions of the system are operating properly.
  • Page 97: Typical Indications Of Issues

    GUI. In turn, if the professional installer and/or link designer contacts Exalt Customer Care, the process to rectify the system is much more expedient due to the in-depth knowledge related to the implementation and the RF environment.
  • Page 98: Improper Transmission System

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Improper Transmission System Improper transmission system is a very common problem. In many cases, this is a problem that occurs during installation and is not a problem that suddenly appears. However, if waveguides are moved or flexed and radio errors, changes in RSL or other performance issues occur, this is a certain sign of this issue.
  • Page 99: Path Obstruction

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios be measured still have an impact on the radio system – especially if the radio system has low fade margin or is using a high order modulation. Changes in frequency, bandwidth, antenna polarization, or antenna position may remedy an interference issue.
  • Page 100: Moisture In The Transmission System

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Moisture in the Transmission System If the connectors on cables and antennas and egress junctions are not properly weatherproofed, moisture can get into the transmission system and cause significant error conditions and erratic performance.
  • Page 101: Back-To-Back Bench Testing

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Back-to-back Bench Testing Use back-to-back bench testing to test the radio before installation, pre-configure the radio and connected equipment before installation, or in the troubleshooting process to identify if the radio hardware is the source of a system issue.
  • Page 102: Specification Performance Verification

    RSL = RF Output Power – cabling losses – total attenuation Verify output power by adjusting output power using the Exalt GUI (in administration mode) and evaluate the corresponding change to the RSL measurement.
  • Page 103 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Once threshold is verified in this direction, repeat the process in the opposite direction by adjusting RF output power of the radio at the opposite end. Return the first radio to its original power setting before adjusting the second radio.
  • Page 104: General Compliance And Safety

    Exalt or your Exalt authorized dealer for assistance. Do not modify this device in any way without the express written consent of Exalt. Modification voids the manufacturer warranty, and may also be illegal in accordance to government regulations. In addition, there are no user-serviceable parts or assemblies inside the product housing.
  • Page 105: Safety Notices

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Safety Notices Review this entire guide for important installation instructions BEFORE attempting to install this product. This product is intended to be installed, used, and maintained by experienced telecommunications personnel only.
  • Page 106: Regulatory Notices

    Shielded cables and I/O cords must be used for this equipment to comply with the relevant FCC regulations. Changes or modifications not expressly approved in writing by Exalt may void the user’s authority to operate this equipment. This device must be professionally installed.
  • Page 107: Canada Compliance

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Canada Compliance The ExtendAir G2 radios operate under RSS-210 of Industry Canada regulations. Operation is subject to the following conditions, unless express permission is granted by Industry Canada to operate in a different manner: •...
  • Page 108: Regulatory Compliance

    ExtendAir G2 Digital Microwave Radios Regulatory Compliance As of this printing, Exalt Communications, Inc. has approvals for the products that are covered by this manual, as indicated in Table 8. If your application or country is not listed, check with your Sales Representative for the current status.
  • Page 109: Licensing

    You must first register with the FCC to use the on-line system, and obtain an FCC Registration Number (FRN). The FRN identifies you in all transactions to the FCC. Exalt provides ExtendAir G2 radio information to the following CFCs: •...
  • Page 110: Exalt Limited Hardware Warranty Software License And Rma Procedures Agreement

    (repair parts and products may be either reconditioned or new, but, if reconditioned, shall be of the same quality as new parts or products); or (C) if Exalt determines that it is unable to repair or replace such Hardware Product, Exalt (or its applicable reseller) will refund to Purchaser the amount actually paid by Purchaser for the applicable Hardware Product.
  • Page 111 This limited warranty will not apply to: (A) any Hardware Product that: (i) has been modified or altered by any party other than Exalt; (ii) has been subject to accident, misuse, abnormal wear and tear, neglect, or mistreatment; (iii) has been damaged during installation of the Hardware Product;...
  • Page 112 Software. Furthermore, except to the extent allowed by applicable law if located in the European Union, and then only with prior written notice to Exalt, You shall not disassemble or reverse engineer the Software in whole or in part or authorize others to do so. No rights to distribute or sublicense the Software are granted herein.
  • Page 113 PRODUCTS" available through the Web user interface application provided with this product. Except as Exalt may otherwise inform You in writing, the Third Party License gives You at least the license rights granted above in Section 6(a), and may provide additional license rights as to the Third Party Software, but only with respect to the particular Third Party Software to which the Third Party License applies.
  • Page 114 Purchaser, or (ii) was in Purchaser's possession prior to disclosure by Exalt. MISCELLANEOUS You shall not sell, transfer or assign this Agreement without the prior written consent of Exalt. Any act in derogation of the foregoing shall be null and void, and You will remain obligated under this Agreement.
  • Page 115: Copyright Notices

    Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Copyright Notices This section presents copyright notices for third-party software licensed to Exalt Communications, Inc. Net-SNMP The following copyright notice applies to the open-source licensing agreement for Net-SNMP. Copyright 1989, 1991, 1992 by Carnegie Mellon University...
  • Page 116 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Cambridge Broadband, Ltd. Portions of this code are copyright (c) 2001-2003, Cambridge Broadband Ltd.
  • Page 117 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS;...
  • Page 118 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ''AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
  • Page 119 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios dimensions-ExtendAir models 67 ACM 43 Adaptive Coded Modulation (ACM) 43 effective isotropic radiated power (EIRP) 7 Administration Settings page 32 Endpoint Identifier 39 administrator privileges 26 Errored Seconds (ES) field 54...
  • Page 120 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios interference profile 5 Radio Information page 31 internal diplexer 5 Radio Name parameter 39 IP address 39 Radio Performance page 54 IP subnet mask 39 Reboot page 65 received signal level (RSL) See RSL...
  • Page 121 Exalt Installation and Management Guide ExtendAir G2 Digital Microwave Radios Time Since Reset 55 transmitter output power 5 Transmitter/Receiver (TR) frequency param- eter 44 traps 36 troubleshooting 62, 88 TX Frequency parameter 44 Unavailable Seconds (UAS) 55 Update button 32...
  • Page 122 208871-001 2013-11-18...

Table of Contents