Mitsubishi Electric PRH-P200MYA Operation Manual
Mitsubishi Electric PRH-P200MYA Operation Manual

Mitsubishi Electric PRH-P200MYA Operation Manual

Air-conditioners rooftop unit
Hide thumbs Also See for PRH-P200MYA:

Advertisement

Quick Links

Air-Conditioners
ROOFTOP UNIT
PRH-P200, 250, 400, 500MYA
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
PARA EL USUARIO
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich
durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du climatiseur.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso
seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro della stessa.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de airconditioner gebruikt.
DRIFTSMANUAL
Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar
condicionado.
Back to Index
PER L'UTENTE
VOOR DE GEBRUIKER
FÖR ANVÄNDAREN
PARA O UTILIZADOR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRH-P200MYA and is the answer not in the manual?

Questions and answers

Summary of Contents for Mitsubishi Electric PRH-P200MYA

  • Page 1 Back to Index Air-Conditioners ROOFTOP UNIT PRH-P200, 250, 400, 500MYA FOR USER PER L’UTENTE FÜR BENUTZER VOOR DE GEBRUIKER POUR L’UTILISATEUR FÖR ANVÄNDAREN PARA EL USUARIO PARA O UTILIZADOR OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2 [Fig. 2.0.1] <A> <B> PRH-P200, 250MYA <A> <B> PRH-P400, 500MYA <A> In case of side flow <B> In case of top flow A Return air B Supply air C Outdoor heat exchanger air inlet D Outdoor heat exchanger air outlet E Fresh air intake [Fig.
  • Page 3: Table Of Contents

    Do not place a gas heater or any other open-flame appliance where it will • Use only accessories authorized by Mitsubishi Electric and ask your be exposed to the air discharged from the unit. Incomplete combustion dealer or an authorized company to install them. If accessories are in- may result.
  • Page 4: Disposing Of The Unit

    • Never wipe the remote controller with benzene, thinner, chemical rags, When the air conditioner is not to be used for a long etc. Doing so can result in discoloration and failure. To remove heavy time stains, soak a cloth in neutral detergent mixed with water, wring it out thoroughly, wipe the stains off, and wipe again with a dry cloth.
  • Page 5 Remote controller-Button TEMP. ON/OFF MENU ON/OFF FILTER BACK MONITOR/SET CHECK TEST Opening the door. PAR-21MAA CLOCK OPERATION CLEAR 0 Filter button (<Enter> button) 1 Set Temperature buttons A Test Run button Down B Check button (Clear button) C Airflow Up/Down button 2 Timer Menu button (Monitor/Set button) 3 Mode button (Return button) Notes:...
  • Page 6: Switching The Unit On/Off

    The microcomputer functions in the following cases: • Air does not blow out when heating starts. - To prevent any cool air from escaping. Wait a moment until the airflow comes out naturally. • The air keeps flowing out, even when the operation has been stopped. ˚C For Approximately 1 minute after the operation stops, the fan sometimes ˚C...
  • Page 7: Using The Timer

    5. Press the Mode (Return) button 2 to complete the setting procedure. This Setup Matrix will return the display to the standard control screen, where 1 will now show <Operation 1 settings for Op No. Sunday Monday ··· Saturday the newly set day and time. Sunday>...
  • Page 8 s To Turn Off the Weekly Timer 6. To clear the current ON or OFF setting: Display the ON or OFF setting (see Press the Timer On/Off button 9 so that “Timer Off” appears at 0. step 3) and then press the Check (Clear) button 0 so that the time setting clears to “—”...
  • Page 9: Locking The Remote Controller Buttons (Operation Function Limit Controller)

    s Checking the Current Auto Off Timer Setting Example 2: Start the timer, with OFF time is sooner than ON time Timer Setting ON Setting: 5 hours OFF Setting: 2 hours TIMER AFTER AFTER Display shows the tim- At Timer Start ˚C AUTO OFF er’s...
  • Page 10: Other Indications

    s How to Lock the Buttons 3.8.3. Flashing “Filter” button 4, press and hold down the ON/ 1. While holding down the Filter OFF button 1 for 2 seconds. The “Locked” indication appears on the screen (at 1), indicating that the lock is now engaged. * If locking has been disabled in Function Selection of remote controller, the screen will display the “Not Available”...
  • Page 11: Caring For The Machine

    Prevent intrusion of heat during air-cooling Carry out ventilation sometimes • To prevent the intrusion of heat during cooling operation, provide a curtain or a • Since the air periodically gets dirty in a room that is kept closed for a long time, blind on the window to block out direct sunlight.
  • Page 12: Installation And Transferring Works, And Checking

    [internal wiring rules], and the installation instruction manual with the absolute use of exclusive circuits. The use of other prod- ucts with the power source can result in burnt-out beakers and fuses. 8. Specifications PRH-P-MYA SERIES Model PRH-P200MYA PRH-P250MYA PRH-P400MYA PRH-P500MYA Item Voltage...
  • Page 13 This product is designed and intended for use in the residential, commer- cial, and light-industrial environment. • Low Voltage Directive 73/23/EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following EU regulations: 336/EEC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.