Page 1
Model fn2000m Pocket Portable Nebulizer User Guide USER: READ THIS GUIDE BEFORE OPERATING THIS DEVICE. SAVE THIS GUIDE FOR FUTURE REFERENCE. Flyp Owners Manual V2.13.indd 1 Flyp Owners Manual V2.13.indd 1 12/1/20 5:48 PM 12/1/20 5:48 PM...
Page 2
DO NOT PLACE (14˚F to 113˚F) IN DISHWASHER -10ºC The symbols that appear on the box and the Flyp™ nebulizer are +45ºC described below: Federal law (USA) restricts this device to sale by or on only DO NOT PLACE the order of a physician or licensed practitioner.
Page 3
This page left blank intentionally. Before using your Flyp nebulizer for the first time, be aware of all warnings and safety information. Only use accessories approved by the manufacturer and referenced within this manual. If you do not fully understand all the warnings, safety precautions, and operating instructions, contact the Flyp customer service team at 844.FLYPNEB (359.7632) for...
About Flyp’s Battery ................21-23 Other information: FCC and bluetooth .......... 54-57 Filling Medication Reservoir with Prescription ........24-25 Turning Flyp ON and OFF ..............26-27 Section 10: Replacement Parts and Accessories ........58 Inhaling Prescribed Medication ............. 28 Flyp Owners Manual V2.13.indd 6-7 Flyp Owners Manual V2.13.indd 6-7...
All warnings and cautions *Note: The mouthpiece of this for use by a single user. Flyp is not such as a hospital or doctor’s office. device is removable. described in the User Guide should a life-saving device.
Flyp for any other purpose is If you are using Flyp to treat a damage to the device or other dangerous, and neither the serious condition, a back-up property. Read all the safety distributor, manufacturer, nor device is recommended.
Page 7
Main Unit or into its USB port. If immerse the battery in water, as you drop medication on either Charge Flyp only with the USB Wall this may cause the battery to •NEVER unscrew or open the Charger provided. NEVER use the area, immediately wipe it off rupture.
Page 8
Draw-String Bag. you have positioned it correctly. heat and cold. Do not leave Flyp in a car if it will be subjected Using cords and ports: Disposing of Flyp properly: to significant heat or cold.
Barely a whisper thanks to hold the power button for 3 HypersoniQ™ Technology. The FEATURES AND BENEFITS Flyp is rechargeable with a seconds. Flashing blue indicator internal disk vibrates 2000x faster USB Wall Charger, like a cell lights appear. Flyp will produce than a hummingbird’s wings.
Section 4: FLYP™ AT A GLANCE NAMES AND FUNCTIONS OF PARTS Read this section to learn the names and functions of the parts. If any items are missing, contact the store where you purchased Flyp. You may also contact Flyp...
NEVER use the device port, just as many cellular phones while it is charging. and portable electronic media *Note: Flyp is designed to shut off devices are charged. automatically after 10 minutes to Flyp has an internal battery that conserve battery life.
Page 12
Solid Blue light & flashing Yellow light Power on, Low battery Connection Flashing Blue and Yellow light Cleaning, Low Battery via wall outlet Flashing Red light Battery requires charging Flyp Owners Manual V2.13.indd 22-23 Flyp Owners Manual V2.13.indd 22-23 12/1/20 5:48 PM 12/1/20 5:48 PM...
Page 13
Squeeze to Then close the Reservoir Cover. Medication Reservoir to fill it with empty medication. contents and fill reservoir. STEP 3 STEP 1 STEP 2 Flyp Owners Manual V2.13.indd 24-25 Flyp Owners Manual V2.13.indd 24-25 12/1/20 5:48 PM 12/1/20 5:48 PM...
Gently raise the Mouthpiece using MOUTHPIECE your index finger, revealing the On-Off Button and On-Off Indicator Light. To turn Flyp™ on, press the On-Off Button. The blue On-Off Indicator Light will light. Visually confirm that an aerosol mist is flowing from the Mouthpiece’s end.
36-37 to see if corrective ALWAYS disconnect and unplug steps can be taken. the USB Wall Charger before cleaning or disinfecting Flyp Owners Manual V2.13.indd 28-29 Flyp Owners Manual V2.13.indd 28-29 12/1/20 5:48 PM 12/1/20 5:48 PM...
Page 16
USB Wall Charger, make sure ion battery inside the Main Unit the USB Cover is closed tightly, and may be dangerous when wet. remove the Mouthpiece. Prepare Flyp Owners Manual V2.13.indd 30-31 Flyp Owners Manual V2.13.indd 30-31 12/1/20 5:48 PM 12/1/20 5:48 PM...
Page 17
2. Fill the reservoir half-way with ~3ml towel. recommended. distilled water. Close the stopper. 7. Power Flyp off by pressing the power 9. Allow the Medication Reservoir button. 1. Check the HypersoniQ cartridge to 3. Gently raise the Mouthpiece with interior to dry fully prior to using again.
Page 18
Remember to open stopper on the end of every day. cartridge. Step 2. Allow Flyp to sit for 5 minutes. Step 2. Soak the mouthpiece and cartridge in 70% ethyl alcohol for Step 3. Moisten with a clean 10 minutes.
Charge Flyp. Refer to pages The battery is low. 22-23. TROUBLESHOOTING If these corrective actions do not return Flyp™ to full working An air bubble Tap the back of the Main nebulization order, read the next section, has formed in the...
Section 8: SUPPORT Section 9: INFORMATION You can find more information about using Flyp™ on our website. TECHNICAL DATA SPECIFICATIONS To learn about service and support, and to view tutorials, go to: www.flypnebulier.com Technical Specifications: Indications for use: Length: 119 mm The Flyp™...
Page 21
90.3% 88.1% Weight: (% mass 0.4-4.7μ) Flyp: 102 g (with battery) * Sum of Coarse (74.7μ), Respirable dose (0.4 – 4.7μ) + Fine (<0.4μ). Dimensions: All data shown at a 95% confidence level. 27 x 119 x 54 mm (Main Unit) Medications were tested 3 times each on 3 devices for a total of 27 sample data points.
All data shown at a 95% confidence level. Medications were tested 3 fields near the medical device. manufacturer as replacement times each on 3 devices for a total of 27 sample data points. Flyp Owners Manual V2.13.indd 42-43 Flyp Owners Manual V2.13.indd 42-43 12/1/20 5:48 PM 12/1/20 5:48 PM...
Page 23
The Flyp™ fn2000m is intended for use in the electromagnetic The equipment or system should environment specified below. The customer or user of the Flyp fn2000m should ensure that it is used in such an environment. not be used adjacent to or stacked with other equipment and that if adjacent or stacked Emissions Test Compliance Electromagnetic Environment –...
Page 24
60601-1-2: 2014, ed. 4.0. The Flyp fn2000m is intended for use in the electromagnetic environment specified below. The customer or user of the Flyp fn2000m should ensure that it Guidance and Manufacturer’s Declaration - Emissions is used in such an environment.
Page 25
Guidance and Manufacturer’s Declaration – Immunity The Flyp™ fn2000m is intended for use in the electromagnetic environment specified below. The customer or user of the Flyp fn2000m should ensure that it is used in such an environment. IEC 60601 Compliance...
Page 26
Guidance and Manufacturer’s Declaration – Immunity The Flyp™ fn2000m is intended for use in the electromagnetic environment specified below. The customer or user of the Flyp fn2000m should ensure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment –...
DISPOSAL & RECYCLING WARRANTY Recommended Separation Distances for the Flyp fn2000m The Flyp™ fn2000m is intended for use in the electromagnetic environment The Flyp main unit is warrantied for a in which radiated disturbances are controlled. The customer or user of the...
Page 28
This the interference by one or more equipment generates, uses and of the following measures: Do Flyp Owners Manual V2.13.indd 55 Flyp Owners Manual V2.13.indd 55 12/1/20 5:48 PM 12/1/20 5:48 PM...
Page 29
If the connection is lost, the device starts to advertise immediately and the App can reconnect. Modulation Technology FHSS (Frequency Hopping Spread Spectrum) Bluetooth Supported Profiles GATT based custom profile for Flyp Modulation Type GFSK Authentication & Encryption Supported...