Model pe1200m
Portable Vibrating
Mesh Nebulizer
User Guide
USER: READ THIS GUIDE BEFORE OPERATING THIS DEVICE.
SAVE THIS GUIDE FOR FUTURE REFERENCE.

Advertisement

Table of Contents
loading

Summary of Contents for flyp pe1200m

  • Page 1 Model pe1200m Portable Vibrating Mesh Nebulizer User Guide USER: READ THIS GUIDE BEFORE OPERATING THIS DEVICE. SAVE THIS GUIDE FOR FUTURE REFERENCE.
  • Page 2 DO NOT PLACE (14˚F to 113˚F) IN DISHWASHER -10ºC The symbols that appear on the box and the FLYP™ nebulizer are described below: Federal law (USA) restricts this device to sale +45ºC only by or on the order of a physician or licensed...
  • Page 3 This page left blank intentionally. Before using your FLYP nebulizer for the first time, please read this User Guide and clean the parts. Be aware of all warnings and safety information. Only use accessories approved by Convexity and referenced within this manual.
  • Page 4: Table Of Contents

    Safety Guidelines 10-15 Section 8: Support Section 3: Product Description Learning More Features and Benefits 16-17 Section 9: Information Section 4: FLYP™ at a Glance Technical Data Names and Functions of Parts 18-20 Specifications 39-40 Aerosol Performance 41-42 Section 5: Using FLYP...
  • Page 5: Section 1: Introduction

    Guide’s contents. FLYP is intended use at home or a medical facility, All warnings and cautions for use by a single user. FLYP is not such as a hospital or doctor’s office. described in the User Guide should a life-saving device. Patients who be observed.
  • Page 6: Section 2: Safety Guidelines

    FLYP for any other purpose is Be sure to clean the Mouthpiece, If you are using FLYP to treat a damage to the device or other dangerous, and neither the Medication Reservoir and Stopper serious condition, a back-up property.
  • Page 7 Do not every day, but it should NEVER be damage it. Overheating and however, avoid operating it near store FLYP for long periods of time placed in water or washed in a injury could result. The lithium- other electronic devices.
  • Page 8 1 unit-dose of medication or 3 heat and cold. Do not leave mL of normal saline (0.9%), the FLYP in a car if it will be subjected device should be replaced. to significant heat or cold.
  • Page 9: Section 3: Product Description

    Section 3: PRODUCT DESCRIPTION FLYP operates almost silently, so it will not disturb children. FEATURES AND BENEFITS FLYP is rechargeable with a USB Wall Charger, like a cell Fast and efficient: Read this section to learn about phone. There are no disposable FLYP delivers 1 unit-dose in FLYP’s features and benefits.
  • Page 10: Section 4: Flyp™ At A Glance

    NEBULIZER DISK Section 4: FLYP™ AT A GLANCE ON/OFF NAMES AND FUNCTIONS INDICATOR LIGHT OF PARTS RESERVOIR COVER STOPPER ON/OFF Read this section to learn the BUTTON MEDICATION names and functions of the parts. RESERVOIR LATCH If any items are missing, contact the store where you purchased FLYP.
  • Page 11: Section 5: Using Flyp

    It may create a hazardous condition. FLYP has an internal battery Note: the Draw-String Bag is that you cannot replace. If Charging FLYP’s battery: not intended to protect FLYP™. It is your battery must be replaced, provided for convenience only.
  • Page 12 You can charge FLYP’s battery To charge the battery with a When FLYP is connected to a wall outlet: power source, the On-Off Indicator by connecting FLYP™ to a wall Light has two possible states: outlet using the USB Wall Charger 1.
  • Page 13: Filling Medication Reservoir With Prescription

    STOPPER STOPPER FILLING MEDICATION RESERVOIR 2. Unplug the Stopper from the 3. Carefully insert your medication 4. Once the medication is in the WITH PRESCRIPTION ampule fully into the Medication Reservoir, reinsert Medication Reservoir. Medication Reservoir. Then the Stopper using your fingers. There is no need to remove the squeeze the entire contents in, Be careful not to touch any...
  • Page 14: Turning Flyp On And Off

    If you removed the Medication To turn FLYP™ on, press the On-Off Reservoir in order to fill it with Button. The blue On-Off Indicator medication or to clean it, you Light will light. Visually confirm will first need to reinsert the...
  • Page 15: Inhaling Prescribed Medication

    Inhale and breathe in a Read this section to learn how to calm manner at a normal rate. RESERVOIR COVER clean FLYP™, both before its first use and after each subsequent use. ALWAYS disconnect and unplug the USB Wall Charger before...
  • Page 16 2. Pull gently on the Medication 3. Unplug the Stopper from the and remove the Mouthpiece. Prepare a solution of warm water Reservoir. Medication Reservoir. and mild liquid dishwashing Prepare a solution of warm water soap. Wash the Mouthpiece and and mild dishwashing soap.
  • Page 17: Disinfecting Parts

    Disinfecting the Mouthpiece and Disinfecting the Main Unit’s interior: using it again. Medication Reservoir: 1. Place FLYP on a flat surface and 3. Close the Reservoir Cover. 1. Remove the Mouthpiece and remove the Mouthpiece. It is important to clean the 4.
  • Page 18 5. Repeat steps 2 and 3 on this side aerosol sprays, solvents, ammonia, Before disinfecting the Main Unit’s 6. Turn FLYP™ on and allow the of the Nebulizer Disk. or abrasives to disinfect FLYP. exterior, make sure the USB Cover mist to flow from the raised 6.
  • Page 19: Section 7: Troubleshooting

    Charge FLYP using a USB The battery is low. port. Refer to pages 22-23. TROUBLESHOOTING If these corrective actions do not return FLYP™ to full working An air bubble Tap the back of the Main nebulization order, read the next section,...
  • Page 20: Section 8: Support

    Section 8: SUPPORT Section 9: INFORMATION TECHNICAL DATA SPECIFICATIONS You can find more information about using FLYP™ on our website. To learn about service and support, and to view tutorials, go to: www.ConvexityScientific.com/support/FLYP Technical Specifications: Indications for use: Length: 119 mm The FLYP™...
  • Page 21: Aerosol Performance

    88.1% (% mass 0.4-4.7μ) Weight: Humidity: up to 93% RH FLYP: 102 g (with battery) All data shown at a 95% confidence level. Medications were tested 3 times each on 3 devices for a total of 27 sample data points.
  • Page 22: Electromagnetic Compatibility

    ELECTROMAGNETIC Medical Electrical Equipment Aerosol Performance needs special precautions COMPATIBILITY Albuterol Ipratropium Cromolyn regarding EMC and needs sulfate bromide sodium to be installed and put into With the increased number service according to the EMC of electronic devices, such Coarse particle dose (μ) 69.2 +/- 36.1 7.4 +/- 3.8 85.7 +/- 37.2...
  • Page 23 The FLYP™ pe1200m is intended for use in the electromagnetic The equipment or system should environment specified below. The customer or user of the FLYP pe1200m should ensure that it is used in such an environment. not be used adjacent to or stacked with other equipment Emissions Test Compliance Electromagnetic Environment –...
  • Page 24 60601-1-2: 2014, ed. 4.0. The FLYP pel200m is intended for use in the electromagnetic environment specified below. The customer or user of the FLYP pel200m should ensure that it Guidance and Manufacturer’s Declaration - Emissions is used in such an environment.
  • Page 25 Guidance and Manufacturer’s Declaration – Immunity The FLYP™ pel200m is intended for use in the electromagnetic environment specified below. The customer or user of the FLYP pel200m should ensure that it is used in such an environment. IEC 60601 Compliance...
  • Page 26 Guidance and Manufacturer’s Declaration – Immunity The FLYP™ pel200m is intended for use in the electromagnetic environment specified below. The customer or user of the FLYP pel200m should ensure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment –...
  • Page 27: Disposal And Recycling

    DISPOSAL & RECYCLING WARRANTY Recommended Separation Distances for the FLYP pel200m The FLYP™ pel200m is intended for use in the electromagnetic environment FLYP is warranted for a period of in which radiated disturbances are controlled. The customer or user of the...
  • Page 28: Section 10: Replacement Parts And Accessories

    Section 10: REPLACEMENT PARTS AND ACCESSORIES PART REORDER NUMBER Mouthpiece AIR-1000 This page left blank intentionally. Medication Reservoir AIR-2000 USB Wall Charger AIR-3000 Draw-String Bag AIR-4000 User Guide AIR-5000...
  • Page 29 CONVEXITY SCIENTIFIC INC. P.O. Box 297 Westport, CT 06880 (203) 557-6254...