Connecting the floor temperature sensor / remote control system

Insert the floor sensor wires through one of the two
openings on the wallplate and connect them to
terminals 1 and 2 (no polarity).
The sensor wires must not come in contact with the
electrical wires and must be routed outside the
electrical box and follow the wall down to the floor.
Position the sensor cable such that it does not
come in contact with the floor heating wires. The
sensor must be centered between two floor heating
wires for best temperature control.
Do NOT staple the sensor head (the plastic end) to
the floor. Doing so might damage the sensor. Any
damage might not be noticeable during testing but
can become apparent several days later.
If you wish to connect a remote control device (see
page 11), insert the wires (use 18- to 22-gauge flexible
wires) through one of the two openings on the wallplate
and connect them to terminals 2 and 3 (no polarity).
8
Floor
temperature
sensor
Remote control device