Durability:
5 years or 180,000 sheets (3,000 per month X
60 months); whichever
Electrical
Voltage:
120 V model: 90 to 132 VAC
Rated frequency
50 Hz to 60 Hz ± 3Hz
range:
Power consumption: Less than 550 W
Insulation
2 MR minimum
resistance:
Dielectric strength (between AC line and
120 V model can withstand 1500 VAC rms
for one minute or 1650 VAC rms for one
second.
Controller hardware
CPU
68000, 12.5 MHz
R A M
Standard: 0.5 MB (expandable up to 6 MB)
Environmental
Temperature:
Operation: 50° to 95° F (10 to 35" C)
Storage: 32° to 95° F (0° to 35° C)
Humidity:
Operation: 1.5 to 85 % RH
Storage: 30 to 85 % RH
Altitude:
8200 feet (2500 meters) maximum
Levelness:
Should be kept level

Interface Specifications

Interface timing
The figure below shows the timing for the parallel interface.
Signal level: TTL compatible
Serial interface
The printer's resident serial interface can be
or RS-422 operation. These interfaces have
characteristics.
Laser Printers
first.
comes
chassis):
for either RS-232C
set
following
the
1/7/91
Data format
7 or 8 bits
Word length:
none, odd or even
Parity:
1 or 2
Stop bits:
Printer ready protocol: enabled (DTR and XON/XOFF protocol
set to ON.)
The data format can be set using functions and menu options in
SelecType.
rate
Baud
300, 600,
1200, 2400, 4800, 9600, 19,200
Signal level
RS-232C: Conforms to EIA
Handshaking
The printer's serial interface can
signal levels and XON/XOFF communication protocols either
separately or in combination. When the vacant area for data in the
input buffer drops to 128 bytes, the printer outputs an XOFF code
or sets the DTR signal level to low (MARK, indicating that it
cannot receive more data).
Once the vacant area for data in the buffer recovers to 256 bytes,
the printer outputs an XON code or sets the DTR flag to high
(SPACE), indicating that it is again ready to receive data.
Error handling
A
character is printed if a parity error, framing error, or over-run
l
error is detected.-
Connector
D-sub 25-pin connector
Interface
Parallel
EPL-7000 LASER PRINTER
bits per second.
DTR (Data Terminal Ready)