Gigabyte R272-Z31 User Manual

Gigabyte R272-Z31 User Manual

Amd epyc 7003 up server system - 2u 24-bay
Hide thumbs Also See for R272-Z31:
Table of Contents

Advertisement

Quick Links

R272-Z30
R272-Z31
R272-Z32
AMD EPYC™ 7003 UP Server System - 2U 24-Bay
User Manual
Rev. 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Gigabyte R272-Z31

  • Page 1 R272-Z30 R272-Z31 R272-Z32 AMD EPYC™ 7003 UP Server System - 2U 24-Bay User Manual Rev. 1.0...
  • Page 2 GIGABYTE's prior written permission. Documentation Classifications In order to assist in the use of this product, GIGABYTE provides the following types of documentation:  User Manual: detailed information & steps about the installation, configuration and use of this product (e.g.
  • Page 3 Conventions The following conventions are used in this user's guide: NOTE! Additional information related to the current topic. CAUTION! Precautionary measures to avoid possible hardware or software problems. WARNING! Alerts to any damage that might result from doing or not doing specific actions.
  • Page 4 Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 5 Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
  • Page 6: Table Of Contents

    Removing and Installing the Power Supply ............ 36 Installing the Mezzanine Card (Optional) ............37 Cable Routing ....................38 3-9-1 R272-Z30 Cable Routing ..................38 3-9-2 R272-Z31 Cable Routing ..................40 3-9-3 R272-Z32 Cable Routing ..................43 Chapter 4 Motherboard Components ................46 Motherboard Components ................46 Jumper Settings ..................... 48 Chapter 5 BIOS Setup ....................50...
  • Page 7 5-2-1 Trusted Computing ....................57 5-2-2 PSP Firmware Versions ..................58 5-2-3 Legacy Video Select ....................59 5-2-4 AST2500 Super IO Configuration ................60 5-2-5 S5 RTC Wake Settings ...................63 5-2-6 Serial Port Console Redirection ................64 5-2-7 CPU Configuration ....................68 5-2-8 PCI Subsystem Settings ..................69 5-2-9 USB Configuration ....................71 5-2-10 Network Stack Configuration ..................73...
  • Page 8 Save & Exit Menu ..................143 5-10 BIOS POST Beep code (AMI standard) ............144 5-10-1 PEI Beep Codes ....................144 5-10-2 DXE Beep Codes ....................144 - 8 -...
  • Page 9: Chapter 1 Hardware Installation

    Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the user manual and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
  • Page 10: Product Specifications

    Total 6 x low profile PCIe Gen4 / Gen3 expansion slots Š (R272-Z30 & Slot_6: 1 x PCIe x16 (Gen4 x16 bus) slot Š R272-Z31) Slot_5: 1 x PCIe x16 (Gen4 x8 bus) slot Š Slot_4: 1 x PCIe x16 (Gen4 x16 bus) slot Š...
  • Page 11 SAS card is required for SAS devices support 4 x SATA in front side and 2 x SATA in rear side are available in default setting (R272-Z31) Total 26 x 2.5" SATA/SAS hot-swappable HDD/SSD bays Front side: 24 x 2.5" SATA/SAS hot-swappable HDD/SSD bays Š...
  • Page 12 (R272-Z30) Rear side_CBP2021: 2 x SATA/SAS ports Š Speed and bandwidth: SATA 6Gb/s or SAS 12Gb/s per port Š (R272-Z31) Front side_CBP20O5: 24 x SATA/SAS ports Š Rear side_CBP2021: 2 x SATA/SAS ports Š Speed and bandwidth: SATA 6Gb/s or SAS 12Gb/s per port Š...
  • Page 13 System Aspeed® AST2500 management controller Š Management GIGABYTE Management Console (AMI MegaRAC SP-X) web interface Š Dashboard Š JAVA Based Serial Over LAN Š HTML5 KVM Š Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.) Š Sensor Reading History Data Š...
  • Page 14 Power Supply 2 x 1200W single PSUs Š 80 PLUS Platinum (R272-Z32) Š AC Input: Š - 100-240V~/ 12-7A, 50-60Hz Š DC Input: Š - 240Vdc/ 6A Š DC Output: Š - Max 1000W/ 100-240V~ Š +12V/ 80.5A Š +12Vsb/ 3A Š...
  • Page 15: System Block Diagram

    System Block Diagram - 15 - Hardware Installation...
  • Page 16 Hardware Installation - 16 -...
  • Page 17: Chapter 2 System Appearance

    HDD#4 HDD#8 HDD#11 HDD#2 HDD#5 HDD#9 HDD#12 R272-Z31 R272-Z32 Description Front Panel LEDs and buttons Front USB 3.0 Port Orange HDD Latches Support NVMe • Please Go to Chapter 2-3 Front Panel LED and Buttons for detail description of function LEDs.
  • Page 18: Rear View

    Rear View R272-Z30 PSU2 (Secondary) PSU1 (Primary) 6 7 8 R272-Z31 PSU2 (Secondary) R272-Z32 PSU1 (Primary) 6 7 8 Description Serial Port VGA Port Mezzanine Card Slot (Option/OCP V2.0 Card) ID Button 10/100/1000 Server management LAN port USB 3.0 Port x 2 GbE LAN Port x 2 USB 3.0 Port...
  • Page 19: Front Panel Led And Buttons

    Front Panel LED and Buttons No. Name Color Status Description Reset Button Press this button to reset the system. Press this button for the server to generate a NMI to the NMI button processor. If multiple-bit ECC errors occur, the server will effectively be halted.
  • Page 20 Green Indicates system is operating normally. Indicates a critical condition, may include: -System fan failure -System temperature Amber System Indicates non-critical condition, may include: Status LED Blink -Redundant power module failure -Temperature and voltage issue Indicates system is not ready, may include: -POST error -NMI error -Processor or terminator is missing...
  • Page 21: Rear System Lan Leds

    Rear System LAN LEDs Name Color Status Description Yellow 1 Gbps data rate 1GbE Green 100 Mbps data rate Speed LED 10 Mbps data rate Link between system and 1GbE Green network or no access Link/ Blink Data transmission or receiving is occurring Activity No data transmission or receiving is occurring...
  • Page 22: Power Supply Unit (Psu) Led

    Power Supply Unit (PSU) LED PSU LED State Description No AC power to all power supplies 1Hz Green Blinking AC present / only standby on / Cold redundant mode 2Hz Green Blinking Power supply firmware updating mode AC cord unplugged or AC power lost; with a second power supply in parallel still with AC input power Amber Power supply critical event causing shut down:...
  • Page 23: Hard Disk Drive Leds

    Hard Disk Drive LEDs R272-Z30 R272-Z31 R272-Z32 HDD Present RAID SKU Rebuilding LED1 Locate HDD Fault Access (No Access) Disk LED Green ON(*1) BLINK (*2) (LED on Back Panel) Amber No RAID configuration Green ON(*1) (via PCH, HBA) Removed HDD Slot...
  • Page 24 This page intentionally left blank System Appearance - 24 -...
  • Page 25: Chapter 3 System Hardware Installation

    Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged by electrostatic discharge. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself. •...
  • Page 26: Removing And Installing The Chassis Cover

    Removing and Installing the Chassis Cover Before you remove or install the system cover • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the chassis covers: Remove the screw securing the back chassis cover. Push down on the indentations located on the side of the chassis cover.
  • Page 27: Removing And Installing The Cpu And Heat Sink

    Removing and Installing the CPU and Heat Sink Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
  • Page 28: Removing And Installing Memory

    Removing and Installing Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
  • Page 29: Removing And Installing The Memory Module

    3-3-2 Removing and Installing the Memory Module Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR4 DIMMs on to this motherboard. Follow these instructions to install a DIMM module: Insert the DIMM memory module vertically into the DIMM slot and push it down.
  • Page 30: Memory Population Table

    3-3-4 Memory Population Table EPYC Memory Speed based on DIMM Population (One DIMM per Channel) DIMM Population DIMM Max EPYC 7003 Type DDR Frequency (MHz) DIMM 0 1R (1 Rank) 3200 RDIMM 2R or 2DR (2 Ranks) 3200 4DR (4 Ranks) 3200 LRDIMM 2S2R (4 Ranks)
  • Page 31: Removing And Installing The Pci Expansion Card

    Removing and Installing the PCI Expansion Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered off and all power sources have been disconnected from the server prior to installing a PCIe card.
  • Page 32: Removing And Installing The Hard Disk Drive

    Removing and Installing the Hard Disk Drive Read the following guidelines before you begin to install the hard disk drive: • Take note of the drive tray orientation before sliding it out. • The tray will not fit back into the bay if it is inserted incorrectly. •...
  • Page 33 Follow these instructions to install a 2.5" hard disk drive into 3.5" HDD Tray: Press the release button. Extend the locking lever. Pull the locking lever in the direction indicated to remove the HDD tray. Align the hard disk drive with the positioning screw on the HDD tray. Secure the hard disk drive with five screws.
  • Page 34 Follow these instructions to install a 2.5" hard disk drive: Press the release button. Extend the locking lever. Pull the locking lever to remove the HDD tray. Align the hard disk drive with the positioning stud on the HDD tray. Slide the hard disk drive into the HDD tray.
  • Page 35: Replacing The Fan Assembly

    Replacing the Fan Assembly Follow these instructions to replace a fan assembly: Flip the latches on the top of the fan outwards. Using the latches, lift up the fan assembly from the chassis. Reverse the previous steps to install the replacement fan assembly. - 35 - System Hardware Installation...
  • Page 36: Removing And Installing The Power Supply

    Removing and Installing the Power Supply Before you remove or install the power supply unit: • Make sure the system is not turned on or connected to AC power. Follow these instructions to replace the power supply: Press the retaining clip on the left side of the power supply unit along the direction of the arrow. Pull the power supply handle at the same time and pull out the power supply unit.
  • Page 37: Installing The Mezzanine Card (Optional)

    Installing the Mezzanine Card (Optional) Follow these instructions to install a mezzanine card: Insert the mezzanine card into the system ensuring that the connector on the mezzanine card connects to the connector on the motherboard. Secure the mezzanine card to the system with three screws. NOTE! Supports OCP V2.0 Card.
  • Page 38: Cable Routing

    Cable Routing 3-9-1 R272-Z30 Cable Routing Front Switch Cable/Front LED Cable Front Panel USB 3.0 Cable HDD Back Plane Board Power Cable HDD Back Plane Board Signal Cable System Hardware Installation - 38 -...
  • Page 39 Rear HDD Back Panel Board SATA Cable Rear HDD Back Panel Board Signal Cable On-Board SATA to HDD Back Panel Board HBA Cable Cable - 39 - System Hardware Installation...
  • Page 40: R272-Z31 Cable Routing

    3-9-2 R272-Z31 Cable Routing Front Switch Cable/Front LED Cable Front Panel USB 3.0 Cable HDD Back Plane Board Power Cable HDD Back Plane Board Signal Cable System Hardware Installation - 40 -...
  • Page 41 Rear HDD Back Panel Board SATA Cable Rear HDD Back Panel Board Signal Cable SAS Expander Card to HDD Back Panel SAS Expander Card to HDD Back Panel Board Cable #1 Board Cable #2 - 41 - System Hardware Installation...
  • Page 42 HBA Card to SAS Expander Card Cable System Hardware Installation - 42 -...
  • Page 43: R272-Z32 Cable Routing

    3-9-3 R272-Z32 Cable Routing Front Switch Cable/Front LED Cable Front Panel USB 3.0 Cable HDD Back Plane Board Power Cable HDD Back Plane Board Signal Cable - 43 - System Hardware Installation...
  • Page 44 Rear HDD Back Panel Board SATA Cable Rear HDD Back Panel Board Signal Cable NVMe Expander Card Cable #0-#3 NVMe Expander Card Cable #4-#7 System Hardware Installation - 44 -...
  • Page 45 NVMe Expander Card Cable #8-#11 NVMe Expander Card Cable #12-#15 NVMe Expander Card Cable #16-#19 NVMe Expander Card Cable #20-#23 - 45 - System Hardware Installation...
  • Page 46: Chapter 4 Motherboard Components

    Chapter 4 Motherboard Components Motherboard Components 15 16 17 18 27 28 Item Description SlimLine SAS Connector (U2_0) SlimLine SAS Connector (U2_1) SlimLine SAS Connector (U2_2) SlimLine SAS Connector (U2_3) Front Panel USB 3.0 Connector Front Panel Connector HDD Back Plane Board Connector M.2 Connector (PCIe3 x4, NGFF-2280) M.2 Connector (PCIe3 x4, NGFF-2280) Motherboard Components...
  • Page 47 USB 2.0 Cable Connector TPM Module Connector Serial Port Cable ConnectorIPMB Connector IPMB Connector BMC Firmware Readiness LED PCIe x16 Slot #1 (Gen3) PCIe x8 Slot #2 (Shared slot with slot #1/Gen3) PCIe x16 Slot #3 (Gen4) PCIe x16 Slot #4 (Gen4) PCIe x16 Slot #5 (Gen4/x8 Signal) PCIe x 16 Slot #6 (Gen4) PCIe x16 Slot #7 (Gen4/Optional)
  • Page 48: Jumper Settings

    Jumper Settings NCSI Switch OCP MEZZ Onboard LAN HSMB_SEL BIOS Defined BIOS Defined PMBUS_SEL BIOS_PWD Clear supervisor password Normal [Default] BIOS recovery mode Normal [Default] BIOS_RCVR Default Clear CMOS CLR_CMOS Enable Motherboard Components - 48 -...
  • Page 49 This page intentionally left blank - 49 - Motherboard Components...
  • Page 50: Chapter 5 Bios Setup

    Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
  • Page 51  Main This setup page includes all the items of the standard compatible BIOS.  Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
  • Page 52: The Main Menu

    The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
  • Page 53 Parameter Description BIOS Information Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information (Note1) BMC Firmware Version Displays BMC firmware version information.
  • Page 54 Parameter Description AGESA PI Version PI Version Displays AGESA PI version information. Onboard LAN Information LAN1 MAC Address (Note) Displays LAN MAC address information. LAN2 MAC Address (Note) Displays LAN MAC address information. System Date Sets the date following the weekday-month-day-year format. System Time Sets the system time following the hour-minute-second format.
  • Page 55: Advanced Menu

    Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen. When Boot Mode Select is set to UEFI (Default) - 55 - BIOS Setup...
  • Page 56 When "Boot Mode Select" is set to Legacy in the Boot > Boot Mode Select section BIOS Setup - 56 -...
  • Page 57: Trusted Computing

    5-2-1 Trusted Computing Parameter Description Configuration Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be Security Device Support available. Options available: Enable, Disable. Default setting is Enable. Select Enable to activate TPM support feature. SPI TPM Support Options available: Enabled, Disabled.
  • Page 58: Psp Firmware Versions

    5-2-2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information. Items on this window are non-configurable. BIOS Setup - 58 -...
  • Page 59: Legacy Video Select

    5-2-3 Legacy Video Select Description Parameter Selects between onboard or external VGA support. OnBrd/Ext VGA Select Options available: Auto, Onboard, External. Default setting is Onboard. - 59 - BIOS Setup...
  • Page 60: Ast2500 Super Io Configuration

    5-2-4 AST2500 Super IO Configuration Description Parameter AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1/2 Press [Enter] for configuration of advanced items. Configuration BIOS Setup - 60 -...
  • Page 61 5-2-4-1 Serial Port 1/2 Configuration - 61 - BIOS Setup...
  • Page 62 Description Parameter Serial Port 1/2 Configuration Enable/Disable the Serial Port (COM). When set to Enabled allows you to configure the Serial port 1/2 settings. When set to Disabled, displays no Serial Port (Note1) configuration for the serial port. Options available: Enabled, Disabled. Default setting is Enabled. Devices Settings Displays the Serial Port 1/2 device settings.
  • Page 63: S5 Rtc Wake Settings

    5-2-5 S5 RTC Wake Settings Parameter Description Enable/Disable system wake on alarm event. Options available: Disabled, Fixed Time, Dynamic Time. When Fixed Time is Wake System from S5 selected, system will wake on the hr::min::sec specified. Default setting is Disabled. - 63 - BIOS Setup...
  • Page 64: Serial Port Console Redirection

    5-2-6 Serial Port Console Redirection Parameter Description Select whether to enable console redirection for specified device. Console COM1/Serial Over redirection enables the users to manage the system from a remote LAN & COM2 Console location. Redirection (Note) Options available: Enabled, Disabled. Default setting is Disabled. Press [Enter] to configure advanced items.
  • Page 65 Parameter Description Parity Š – A parity bit can be sent with the data bits to detect some transmission errors. – Even: parity bit is 0 if the num of 1's in the data bits is even. – Odd: parity bit is 0 if num of 1's in the data bits is odd. –...
  • Page 66 Parameter Description Legacy Console Redirection Press [Enter] to configure advanced items. Redirection COM Port Š – Selects a COM port for Legacy serial redirection. – Options available: COM1/SOL, COM2. Default setting is COM1/ SOL. Resolution Š – Selects the number of rows and columns used in Console Legacy Console Redirection Redirection for legacy OS support.
  • Page 67 Parameter Description Flow Control Š – Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are full, a 'stop' signal can Serial Port for Out-of-Band be sent to stop the data flow. Once the buffers are empty, a 'start' EMS Console Redirection signal can be sent to re-start the flow.
  • Page 68: Cpu Configuration

    5-2-7 CPU Configuration Description Parameter Enable/Disable the CPU Virtualization. SVM Mode Options available: Enabled, Disabled. Default setting is Enabled. Press [Enter] to view the memory information related to CPU 0. CPU 0 Information BIOS Setup - 68 -...
  • Page 69: Pci Subsystem Settings

    5-2-8 PCI Subsystem Settings - 69 - BIOS Setup...
  • Page 70 Description Parameter Displays the PCI Bus Driver version information. PCI Bus Driver Version Change the PCIe lanes. PCIE_# Lanes Configuration Options available: Disabled, Auto, x8, x4x4, x16, x8x8, x8x4x4, (Note1) x4x4x8, x4x4x4x4. Default setting is Auto. When enabled, this setting will initialize the device expansion ROM PCIE # I/O ROM for the related PCI-E slot.
  • Page 71: Usb Configuration

    5-2-9 USB Configuration Parameter Description USB Configuration USB Module Version Displays the USB module version information. USB Controllers Displays the supported USB controllers. USB Devices: Displays the USB devices connected to the system. Enable/Disable the Legacy USB support function. AUTO option disables legacy support if no USB devices are connected.
  • Page 72 Parameter Description USB hardware delays and time-outs Selects the time-out value for USB Control/Bulk/Interrupt transfers. USB transfer time-out Options available: 1 sec, 5 sec, 10 sec, 20 sec. Default setting is 20 sec. Selects the time-out value during a USB mass storage device reset.
  • Page 73: Network Stack Configuration

    5-2-10 Network Stack Configuration Parameter Description Enable/Disable the UEFI network stack. Network Stack Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 PXE feature. Ipv4 PXE Support (Note) Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 HTTP feature. Ipv4 HTTP Support (Note) Options available: Enabled, Disabled.
  • Page 74: Nvme Configuration

    5-2-11 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system. BIOS Setup - 74 -...
  • Page 75: Sata Configuration

    5-2-12 SATA Configuration Parameter Description Displays the installed HDD devices information. System will automatically SATA Configuration detect HDD type. - 75 - BIOS Setup...
  • Page 76: Uefi Post Logo Configuration

    5-2-13 UEFI POST LOGO Configuration Parameter Description Selects output device type. Output Device Type Options available: First loaded Device, Onboard Device, External Device, Specific Device. Default setting is Onboard Device. BIOS Setup - 76 -...
  • Page 77: Amd Mem Configuration Status

    5-2-14 AMD Mem Configuration Status Description Parameter Press [Enter] to view the memory configuration status related to CPU 0. CPU 0 - 77 - BIOS Setup...
  • Page 78: T1S Auth Configuration

    5-2-15 T1s Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert Š – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444-1234567890ab format. –...
  • Page 79: Intel(R) I350 Gigabit Network Connection

    5-2-16 Intel(R) I350 Gigabit Network Connection - 79 - BIOS Setup...
  • Page 80 Description Parameter Press [Enter] to configure advanced items. Link Speed Š – Allows for automatic link speed adjustment. – Options available: Auto Negotiated, 10 Mbps Half, 10 Mbps Full, 100 Mbps Half, 100 Mbps Full. Default setting is Auto Negotiated. Wake On LAN NIC Configuration Š...
  • Page 81: Vlan Configuration

    5-2-17 VLAN Configuration BIOS Setup - 81 -...
  • Page 82 Parameter Description Press [Enter] to configure advanced items. Create new VLAN Š VLAN ID Š – Sets VLAN ID for a new VLAN or an existing VLAN. – Press the <+> / <-> keys to increase or decrease the desired values. –...
  • Page 83: Mac Ipv4 Network Configuration

    5-2-18 MAC IPv4 Network Configuration Parameter Description Indicates whether network address is configured successfully or not. Configured Options available: Enabled, Disabled. Default setting is Disabled. Options available: Enabled, Disabled. Default setting is Enabled. Enable DHCP (Note) Local IP Address Press [Enter] to configure local IP address. (Note) Press [Enter] to configure local NetMask.
  • Page 84: Mac Ipv6 Network Configuration

    5-2-19 MAC IPv6 Network Configuration - 84 - BIOS Setup...
  • Page 85 Parameter Description Press [Enter] to configure advanced items. Displays the MAC Address information. Š Interface ID Š – The 64 bit alternative interface ID for the device. The string is colon separated. e.g. ff:dd:88:66:cc:1:2:3. DAD Transmit Count Š – The number of consecutive Neighbor solicitation messages sent Enter Configuration Menu while performing Duplicate Address Detection on a tentative address.
  • Page 86: Amd Cbs Menu

    AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU-related information that the BIOS automatically sets. Select a submenu item, then press [Enter] to access the related submenu screen. - 86 - BIOS Setup...
  • Page 87 5-3-1 CPU Common Options BIOS Setup - 87 -...
  • Page 88: Cpu Common Options

    Parameter Description CPU Common Options Performance Press [Enter] for configuration of advanced items. Prefetcher settings Press [Enter] for configuration of advanced items. Core Watchdog Press [Enter] for configuration of advanced items. From a workaround for GCC/C000005 issue for XV Core on CZ A0, setting MSRC001_1029 Decode Configuration (DE_CFG) bit 14 RedirectForReturnDis [DecfgNoRdrctForReturns] to 1.
  • Page 89 Parameter Description Action to take when a CCD BIST failure is detected. Action on BIST Failure Options available: Do nothing, Down-CCD, Auto. Default setting is Auto. Default is 1, cab be set to zero for analysis purpose as long as OS supports Fast short REP MOVSB Options available: Disabled, Enabled.
  • Page 90 5-3-1-1 Performance Parameter Description Performance Options available: Normal Operation, Customized. Default setting is Normal OC Mode (Note) Operation. Allows you to accept or decline enabling Custom Core Pstates. When Custom Core Pstates accepted, you can disable or customize core pstates. Allows you to accept or decline enabling CCDs, processor cores and threads.
  • Page 91 5-3-1-2 Prefetcher Settings Parameter Description Prefetcher settings Enable/Disable L1 Stream HW Prefetcher. L1 Stream HW Prefetcher Options available: Auto, Enable, Disable. Default setting is Enable. Use memory access history of individual instructions to fetch additional lines when each access is a constant distance from the previous. L1 Stride Prefetcher Enable/Disable L1 Stride Prefetcher.
  • Page 92 5-3-1-3 Core Watchdog Parameter Description Core Watchdog Enable/Disable CPU Watchdog Timer. Core Watchdog Timer Enable Options available: Auto, Enabled, Disabled. Default setting is Auto. - 92 - BIOS Setup...
  • Page 93: Df Common Options

    5-3-2 DF Common Options Parameter Description DF Common Options Scrubber Press [Enter] for configuration of advanced items. Memory Addressing Press [Enter] for configuration of advanced items. ACPI Press [Enter] for configuration of advanced items. Link Press [Enter] for configuration of advanced items. Enable/Disable SyncFlood to UMC &...
  • Page 94 5-3-2-1 Scrubber Parameter Description Scrubber Provide a value that is the number of hours to scrub memory. DRAM scrub time Options available: Auto, Disabled, 1 hour, 4 hours, 8 hours, 16 hours, 24 hours, 48 hours. Default setting is Auto. Enable/Disable the Poison scrubber control feature.
  • Page 95 5-3-2-2 Memory Addressing Parameter Description Memory Addressing Specifies the number of desired NUMA nodes per socket. NUMA nodes per socket Options available: Auto, NPS0, NPS1, NPS2, NPS4. Default setting is Auto. Enable/Disable the Memory interleaving feature. Memory interleaving Options available: Auto, Disabled. Default setting is Auto. Controls the memory interleaving size.
  • Page 96 5-3-2-3 ACPI Parameter Description ACPI ACPI SRAT L3 Cache As Enable/Disable report each L3 cache as a NUMA Domain to the OS. NUMA Domain Options available: Auto, Enabled, Disabled. Default setting is Auto. Determines how the SLIT distances are declared. ACPI SLIT Distance Control Options available: Auto, Manual.
  • Page 97 5-3-2-4 Link Parameter Description Link Enable/Disable GMI link encryption. GMI encryption control Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable xGMI link encryption. xGMI encryption control Options available: Auto, Enabled, Disabled. Default setting is Auto. CAKE CRC perf bounds Options available: Auto, Manual.
  • Page 98: Umc Common Options

    5-3-3 UMC Common Options Parameter Description UMC Common Options DDR4 Common Options Press [Enter] for configuration of advanced items. DRAM Memory Mapping Press [Enter] for configuration of advanced items. NVDIMM Press [Enter] for configuration of advanced items. Memory MBIST Press [Enter] for configuration of advanced items. - 98 - BIOS Setup...
  • Page 99 5-3-3-1 DDR4 Common Options Parameter Description DDR4 Common Options Press [Enter] to configure the Plan of Record (POR) to enable / disable restrictions for DDR4 frequency and voltage programming. Memory speeds will be capped at AMD guidelines. Decline Š Accept Š...
  • Page 100 5-3-3-1-1 DRAM Controller Configuration Parameter Description DRAM Controller Configuration Press [Enter] to configure DRAM Power Options. Power Down Enable Š DRAM Power Options – Enable/Disable DDR power down mode. – Options available: Auto, Enabled, Disabled. Default setting is Auto. Selects the Cmd2T mode on ADDR/CMD. Cmd2T Options available: Auto, 1T, 2T.
  • Page 101 5-3-3-1-2 CAD Bus Configuration Parameter Description CAD Bus Configuration Setup time on CAD bus signals to Auto or Manual. CAD Bus Timing User Controls Options available: Auto, Manual. Default setting is Auto. CAD Bus Drive Strength User Drive Strength on CAD bus signals to Auto or Manual. Controls Options available: Auto, Manual.
  • Page 102 5-3-3-1-3 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Specifies the mode for drive strength to Auto or Manual. Controls Options available: Auto, Manual. Default setting is Auto. - 102 - BIOS Setup...
  • Page 103 5-3-3-1-4 Common RAS Parameter Description Common RAS Enable/Disable the Data Poisoning function. Data Poisoning Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable the DRAM Post Package Repair function. DRAM Post Package Repair Options available: Enable, Disable. Default setting is Disable. Enable/Disable the RCD Parity function.
  • Page 104 Parameter Description Disable Memory Error Injection Options available: False, True. Default setting is True. Press [Enter] to configure advanced items. DRAM ECC Symbol Size Š – Configures the DRAM ECC Symbol Size. – Options available: Auto, x4, x8, x16. Default setting is Auto. DRAM ECC Enable Š...
  • Page 105 5-3-3-1-5 Security Parameter Description Security Enable/Disable transparent secure memory encryption. TSME Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable Data Scrambling. Data Scramble Options available: Auto, Enabled, Disabled. Default setting is Auto. BIOS Setup - 105 -...
  • Page 106 5-3-3-1-6 Phy Configuration Parameter Description Phy Configuration Press [Enter] to configure PMU Training. DFE Read Training Š – Perform 2D Read Training with DFE on. – Options available: Auto, Enable, Disable. Default setting is Auto. PMU Training FFE Write Training Š...
  • Page 107 5-3-3-2 DRAM Memory Mapping Parameter Description DRAM Memory Mapping Interleave memory blocks across the DRAM chip selects for node 0. Chipselect Interleaving Options available: Auto, Disabled. Default setting is Auto. Configures the BankGroupSwap. BankGroupSwap (BGS) is a new memory mapping option in AGESA that alters how applications get assigned to BankGroupSwap physical locations within the memory modules.
  • Page 108 5-3-3-3 NVDIMM Parameter Description NVDIMM Displays the information of the devices/controllers if installed Disable NVDIMM-N Enable/Disable NVDIMM-N feature for memory margin tool. Feature Options available: No, Yes. Default setting is NO. - 108 - BIOS Setup...
  • Page 109 5-3-3-4 Memory MBIST Parameter Description Memory MBIST Enable/Disable the Memory MBIST function. MBIST Enable Options available: Enabled, Disabled. Default setting is Disabled. Selects MBIST Test Mode. Interface Mode: Tests Single and Multiple CS transactions and Basic Connectivity. MBIST Test Mode (Note) Data Eye Mode: Measures Voltage vs.
  • Page 110 Parameter Description Selects the Vendor specific tests to use with BIOS memory healing BIST. Mem BIST Test Select (Note1) Options available: Vendor Tests Enabled, Vendor Tests Disabled, All Tests - All Vendors. Default setting is Vendor Tests Enabled. Selects the repair type for dram errors found in the BIOS memory BIST. Mem BIST Post Package Options available: Soft Repair, Hard Repair, No Repairs - Test only.
  • Page 111 5-3-3-4-1 Data Eye Parameter Description Data Eye Pattern Select Options available: PRBS, SSO, Both. Default setting is PRBS. Pattern Length Determines the pattern length. The possible options are N=3..12. This item helps read the aggressors channels. Aggressor Channel Options available: Disabled, 1 Aggressor Channel, 3 Aggressor Channels, 7 Aggressor Channels.
  • Page 112 Parameter Description Target Static Lane Select This item is configurable when Target Static Lane Control is set to Upper 32 bits Enabled. Target Static Lane Select This item is configurable when Target Static Lane Control is set to Lower 32 bits Enabled.
  • Page 113: Nbio Common Options

    5-3-4 NBIO Common Options Parameter Description NBIO Common Options Enable/Disable the IOMMU function. IOMMU Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable DMAr system protection during POST. DMAr Support Options available: Enabled, Disabled, Auto. Default setting is Auto. Enable/Disable Alternative Routing-ID Interpretation. PCIe ARI Support Options available: Auto, Enabled, Disabled.
  • Page 114 Parameter Description Controls the Hot Plug Handling mode. Options available: Auto, A0 Mode, OS First (No Error Handling), Hot Plug Handling mode OS First (Error Handling-Not Implemented), Firmware First (Not Implemented). Default setting is Auto. Presence Detect Select Controls the Presence Detect Select mode. Options available: Auto, OR, AND.
  • Page 115 5-3-4-1 SMU Common Options Parameter Description SMU Common Options Power Policy Quick Options available: Standard, Best Performance, Energy Efficient. Setting Default setting is Best Performance. Selects use the fused Determinism or set customized Determinism. Determinism Control Options available: Auto, Manual. Default setting is Auto. Determinism Slider Options available: Auto, Power, Performance.
  • Page 116 Parameter Description Enable/Disable DF C-states. DF Cstates Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable the CPPC feature. CPPC Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable the HSMP support. HSMP Support Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable the DLWM support.
  • Page 117 5-3-4-2 NBIO RAS Common Options Parameter Description NBIO RAS Common Options NBIO RAS Control Options available: Disabled, MCA, Legacy. Default setting is MCA. Configures the Egress Poison High Severity. Each bit set to 1 enables Egress Poison Severity High High severity on the associated IOHC egress port. A bit of 0 indicates LOW severity.
  • Page 118 Parameter Description Uncorrected Converted to Enables mask for masking of uncorrectable parity errors on internal Poison Enable Mask High arrays. Uncorrected Converted to Enables mask for masking of uncorrectable parity errors on internal Poison Enable Mask Low arrays. Specifies the timer interval of the SYSHUB Watchdog timer in System Hub Watchdog Timer milliseconds.
  • Page 119: Fch Common Options

    5-3-5 FCH Common Options Parameter Description FCH Common Options AC Power Loss Options Press [Enter] for configuration of advanced items. FCH RAS Options Press [Enter] for configuration of advanced items. Miscellaneous Options Press [Enter] for configuration of advanced items. BIOS Setup - 119 -...
  • Page 120 5-3-5-1 AC Power Loss Options Parameter Description AC Power Loss Options Selects the AC Loss Control Method. AC Loss Control Options available: Power Off, Power On, Last State. Default setting is Last State. - 120 - BIOS Setup...
  • Page 121 5-3-5-2 FCH RAS Options Parameter Description FCH RAS Options Enable/Disable the ALink RAS Support. ALink RAS Support Options available: Auto, Enabled, Disabled. Default setting is Auto. Enables AB to forward downstream sync-flood message to system Reset after sync flood controller. Options available: Auto, Enabled, Disabled.
  • Page 122 5-3-5-3 Miscellaneous Options Parameter Description Miscellaneous Options Enable/Disbale Boot Timer. Boot Timer Enable Options available: Auto, Enabled, Disabled. Default setting is Auto. - 122 - BIOS Setup...
  • Page 123: Ntb Common Options

    5-3-6 NTB Common Options Parameter Description NTB Common Options Socket-0 P0 NTB Enable Options available: Auto, Enable. Default setting is Auto. Socket-0 P1 NTB Enable Options available: Auto, Enable. Default setting is Auto. Socket-0 P2 NTB Enable Options available: Auto, Enable. Default setting is Auto. Socket-0 P3 NTB Enable Options available: Auto, Enable.
  • Page 124: Soc Miscellaneous Control

    5-3-7 SOC Miscellaneous Control Parameter Description SOC Miscellaneous Control Enable/Disable the ConsoleOut function for ABL. ABL Console Out Control Options available: Auto, Enabled, Disabled. Default setting is Auto. ABL Basic Console Out Enable/Disable the Basic ConsoleOut function for ABL. Options available: Auto, Enabled, Disabled. Default setting is Auto. Control (Note) To Control the total number of PMU debug messages.
  • Page 125: Workload Tuning

    5-3-8 Workload Tuning Parameter Description Workload Tuning Select the profile for different workloads. Default setting is Auto. Workload Profile Enable to allow capturing performance traces. Performance Tracing Options available: Auto, Enabled, Disabled. Default setting is Auto. BIOS Setup - 125 -...
  • Page 126: Amd Pbs Menu

    AMD PBS Menu AMD PBS Option menu displays submenu options for configuring the function of AMD PBS. Select a submenu item, then press [Enter] to access the related submenu screen. Parameter Description Press [Enter] for configuration of advanced items. Enable/Disable SPI Locking for protect ROM part. SPI Locking Options available: Enabled, Disabled.
  • Page 127: Ras

    5-4-1 RAS Parameter Description Enable/Disable the Periodic SMI for polling [MCA Threshold] error. RAS Periodic SMI Control Options available: Enabled, Disabled. Default setting is Enabled. SMI Threshold Configures the SMI Threshold value. SMI Scale Configures the SMI Scale value. Defines the unit of time scale. SMI Scale Unit Options available: millisecond, second, minute.
  • Page 128 Parameter Description PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Mask register of Root Port. Mask Reg PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Severity register of Root Port. Sev Reg PCIe Device Corr Err Mask Initialize the PCIe AER Corrected Error Mask register of PCIe device.
  • Page 129: Chipset Setup Menu

    Chipset Setup Menu Chipset Setup menu displays submenu options for configuring the function of the North Bridge. Select a submenu item, then press <Enter> to access the related submenu screen. Parameter Description PCIe Compliance Mode Options available: On, Off. Default setting is Off. Enable/Disable program all VR on MB.
  • Page 130: North Bridge

    5-5-1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information. CPU 0 Information Press [Enter] to view information related to CPU 0. - 130 - BIOS Setup...
  • Page 131: Fabric Resource

    5-5-2 Fabric Resource Parameter Description Fabric Resource CPU 0 NBIO_# PCIe Bus Change CPU 0 NBIO_# PCIe Bus Number. Number BIOS Setup - 131 -...
  • Page 132: Server Management Menu

    Server Management Menu Parameter Description Enable/Disable FRB-2 timer (POST timer). FRB-2 Timer Options available: Enabled, Disabled. Default setting is Enabled. Configures the FRB2 Timer timeout. FRB-2 Timer (Note1) Options available: 3 minutes, 4 minutes, 5 minutes, 6 minutes. Default setting is 6 timeout minutes.
  • Page 133 Parameter Description System Event Log Press [Enter] to configure advanced items. View FRU Press [Enter] to view the FRU information. Information BMC network Press [Enter] to configure advanced items. configuration IPv6 BMC Network Press [Enter] to configure advanced items. Configuration BIOS Setup - 133 -...
  • Page 134: System Event Log

    5-6-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Enabled, Disabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Erase SEL Options available: No/Yes, On next reset/Yes, On every reset.
  • Page 135: View Fru Information

    5-6-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased BIOS Setup - 135 -...
  • Page 136: Bmc Network Configuration

    5-6-3 BMC Network Configuration Parameter Description BMC network configuration Lan Channel 1 Selects to configure LAN channel parameters statically or dynamically (DHCP). Do nothing option will not modify any BMC network parameters Configuration Address source during BIOS phase. Options available: Unspecified, Static, DynamicBmcDhcp. Default setting is DynamicBmcDhcp.
  • Page 137: Ipv6 Bmc Network Configuration

    5-6-4 IPv6 BMC Network Configuration Parameter Description IPv6 BMC network configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS IPv6 BMC Lan Option phase.
  • Page 138: Security Menu

    Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
  • Page 139: Secure Boot

    5-7-1 Secure Boot The Secure Boot submenu is applicable when your device is installed the Windows 8 (or above) operating ® system. Parameter Description System Mode Displays if the system is in User mode or Setup mode. Enable/ Disable the Secure Boot function. Secure Boot Options available: Enabled, Disabled.
  • Page 140 Parameter Description Press [Enter] to configure advanced items. Please note that this item is configurable when Secure Boot Mode is set to Custom. Factory Key Provision Š – Allows to provision factory default Secure Boot keys when system is in Setup Mode.
  • Page 141: Boot Menu

    Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting.
  • Page 142 Parameter Description FIXED BOOT ORDER Priorities Press [Enter] to configure the boot priority. By default, the server searches for boot devices in the following sequence: Hard drive. Boot Option #1 / #2 / #3 / #4 / #5 CD-COM/DVD drive. USB device.
  • Page 143 Save & Exit Menu The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press <Enter>. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save Changes and Exit Options available: Yes, No.
  • Page 144 5-10 BIOS POST Beep code (AMI standard) 5-10-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...

This manual is also suitable for:

R272-z30R272-z32

Table of Contents