Operating Specifications; Connector Ports - Cabletron Systems TRMM Installation Manual

Token ring management modules
Hide thumbs Also See for TRMM:
Table of Contents

Advertisement

INSTALLATION REQUIREMENTS AND SPECIFICATIONS
Table 2-2. Modem Configuration Setup Requirements (Sheet 3 of 3)
Command Line
3. AT&D0 <CR>
4. AT&R0 <CR>
4. ATM1 <CR>
5. ATQ1 <CR>
6. AT&W0 <CR>
<CR>
7. AT&W1
Connect the modem that you just configured to the module. You
can now access a management module's Local Management
application via modem connection. See Section 3.4.2 for
instructions on connecting a modem cable to a module.

2.2 OPERATING SPECIFICATIONS

This section contains the operating specifications for the TRMM and
TRMMIM. Cabletron Systems reserves the right to change these
specifications at any time without notice.

2.2.1 Connector Ports

Both modules are equipped with two female DB-9 connector ports
(Figure 2-2). The COM 1 port supports UPS device monitoring, and the
COM 2 port supports terminal and modem access to Local Management.
NOTE: Although some earlier version modules' COM ports are labeled
Modem and Console respectively, they also provide the same functionality
as modules with COM ports labeled COM 1 and COM 2.
2-6
Function
Ignore DTR signal
Follow standard RS232 RTS operation
Speaker until signal active
Disable result codes
Save changes to NVRAM, profile 0
Save changes to NVRAM, profile 1