Warm Up/Initial Start Up

Slide back panel to the right and put switch in upper ON position.
LCD will display the following screens:
a. '46 HAWK 3.0
b. BATTERY %
c. WARM UP
d. ALARM 1 PPM? ALARM 5 PPM? ALARM 50 PPM? ALARM 500 PPM? ALARM 5000 PPM?
i. The alarms will display in the above sequence. Press Operation Button when you
e. MUTE/HEADSET?
i. Press Operation Button if you want to mute alarm and utilize headset. If not,
f.
CLEARING CELL
i. This takes approximately one minute.
g. START SURVEY 0 PPM
i. 0 PPM indicates that you are ready to survey.

Daily Response Test

When at 0 PPM, twist demand flow regulator on to 1000 PPM test glass cylinder. Disconnect the
quick connect between the filter and cone on top.
Connect demand flow regulator tubing with barb to quick connect on probe.
The LCD should display 2% - 3% LEL.
Disconnect demand flow regulator with gas cylinder.
LCD should then display 0 PPM.
If the reading is not 2% - 3% LEL, calibrate (see Calibration Procedure below).
Reconnect cone and tubing to the probe quick connect.

Calibration Procedure

Start with LCD at 0 PPM, then press the Operation Button and hold until Option Menu appears.
The Option Menu will scroll through the following:
a. GO TO SURVEY?
b. ALARM LEVEL?
c. REZERO?
d. CALIBRATE?
e. MUTE ALARM?
i.
The LCD will now display ZERO CHECK. Do not press the button; wait approximately 1.5 minutes.
The LCD will display ENTER 1000 PPM. Twist demand flow regulator onto 1000 PPM test gas
cylinder.
Disconnect quick connect between filter and cone on probe.
reach the desired alarm point. You MUST choose an alarm level.
briefly wait until the unit automatically goes on to the next step.
Press the Operation Button when CALIBRATE? appears.
'46 Hawk 3.0 Quick Start Guide
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 46 Hawk 3.0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Southern Cross 46 Hawk 3.0

  • Page 1 ’46 Hawk 3.0 Quick Start Guide Warm Up/Initial Start Up • Slide back panel to the right and put switch in upper ON position. • LCD will display the following screens: a. ’46 HAWK 3.0 b. BATTERY % c. WARM UP d.
  • Page 2 • Error Message: If an ERROR MESSAGE is displayed, note error code number. Turn off instrument. Ensure clean filters are installed, then restart. If error continues, call Southern Cross Support at 1 (800) 241-5057. Other Techniques: Relocate to a noncontaminated environment, recalibrate, shut off, and restart •...

Table of Contents