Sharp R-2277 Service Manual page 18

Table of Contents

Advertisement

R-2277
R-2287
PROCEDURE
LETTER
O
SWITCH UNIT TEST
1. CARRY OUT 3D CHECKS.
2. Remove the switch unit from the control panel, referring to control panel removal.
3. To test the switches (SW1-SW5) on the switch unit, check between the terminals of the connector
CN-F as described in the following table by using ohmmeter when the switches are released and
depressed.
P
RELAY TEST
CARRY OUT 3D CHECKS.
Remove the outer case and check voltage between Pin Nos. 5 and 7 of the connector (A) on the
control unit with an A.C. voltmeter. The meter should indicate 230 volts, if not check control unit
circuity.
RY1, RY2 and RY3 Relay Test
These relays are operated by D.C. voltage.
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated ............................. Defective relay.
DC. voltage not indicated ....................... Check diode which is connected to the relay coil.
RELAY SYMBOL
CARRY OUT 4R CHECKS.
Q
PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED WIRING
BOARD(PWB) IS OPEN
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary
on the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide
given below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS.
STEPS
1
2
3
4
TEST PROCEDURES (CONT'D)
Switches
Terminals
SW1
F1 - F4
SW2
F1 - F5
SW3
F2 - F4
SW4
F2 - F5
SW5
F3 - F4
OPERATIONAL VOLTAGE
RY1
APPROX. 18.0V D.C.
RY2
APPROX. 17.5V D.C.
RY3
APPROX. 17.5V D.C.
OCCURANCE
The rated AC voltage is not present at
POWER terminal of CPU connector (CN-A)
The rated AC voltage is present at primary
side of low voltage transformer.
Only pattern at "a" is broken.
Pattern at "a" and "b" are broken.
COMPONENT TEST
Released Depressed
O.C.
S.C.
O.C.
S.C.
O.C.
S.C.
O.C.
S.C.
O.C.
S.C.
If diode is good, control unit is defective.
CONNECTED COMPONENTS
Oven lamp,Blower motor and Stirrer motor
Power transformer 1
Power transformer 2
CAUSE OR CORRECTION
Check supply voltage and oven power cord.
Low voltage transformer or secondary circuit defective.
Check and repair.
*Insert jumper wire J9 and solder.
(CARRY OUT 3D CHECKS BEFORE REPAIR)
*Insert the coil RCILF2003YAZZ between "c" and "d".
(CARRY OUT 3D CHECKS BEFORE REPAIR)
16
O.C. : Open Circuit
S.C. : Short Circuit

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-2287

Table of Contents