SEI Industries Bambi Max Technical Bulletin

Ivc cable installation
Hide thumbs Also See for Bambi Max:

Advertisement

 
Technical Bulletin 
Date: 
 
June 1, 2015
Product Line:
 Bambi 
Models:
 Bambi Max 
Subject:
 IVC cable installation 
Background 
Older Bambi Max manuals instruct operators to fasten the IVC power cable to the IDS hub and 
deployment cable using zip‐ties. Operators are instructed to provide some slack during installation. 
Despite this, SEI has observed incidences of the power cable being pulled from the strain relief on the 
IVC, resulting in water ingress. The zip‐tie may gradually work along the power cable over time and 
eliminate slack.  
Recommendations 
SEI recommends that operators avoid fastening the power cable to the IDS or IDS deployment cable all 
together. Instead the operators should fasten the cable directly to the bucket head with 4 zip‐ties as 
illustrated in Figure 1. Operators must ensure that there is at least 6" of slack in the line. It is 
recommended that operators quickly check that there is adequate slack in the line before flight. 
New buckets will already have the installation shown in Figure 1. 
SEI Industries Ltd. 7400 Wilson Avenue, Delta, B.C. Canada V4G 1H3
T: 604.946.3131
seisales@sei-ind.com
www.sei-ind.com
Page 1 of 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bambi Max and is the answer not in the manual?

Questions and answers

Summary of Contents for SEI Industries Bambi Max

  • Page 1 Date:    June 1, 2015 Product Line:  Bambi  Models:  Bambi Max  Subject:  IVC cable installation  Background  Older Bambi Max manuals instruct operators to fasten the IVC power cable to the IDS hub and  deployment cable using zip‐ties. Operators are instructed to provide some slack during installation.  Despite this, SEI has observed incidences of the power cable being pulled from the strain relief on the  IVC, resulting in water ingress. The zip‐tie may gradually work along the power cable over time and  eliminate slack.   Recommendations  SEI recommends that operators avoid fastening the power cable to the IDS or IDS deployment cable all  together. Instead the operators should fasten the cable directly to the bucket head with 4 zip‐ties as  illustrated in Figure 1. Operators must ensure that there is at least 6” of slack in the line. It is  recommended that operators quickly check that there is adequate slack in the line before flight.  New buckets will already have the installation shown in Figure 1.  SEI Industries Ltd. 7400 Wilson Avenue, Delta, B.C. Canada V4G 1H3 T: 604.946.3131 seisales@sei-ind.com www.sei-ind.com Page 1 of 2...
  • Page 2     Figure 1 ‐ Recommended Layout  This Technical Bulletin is available on the SEI website. http://www.sei-ind.com/resources/manuals For further details, please contact the following SEI representatives.   Contact  Robert Button  Product Engineer, Firefighting Division  604‐946‐3131 ext. 423  robert@sei‐ind.com     SEI Industries Ltd. 7400 Wilson Avenue, Delta, B.C. Canada V4G 1H3 T: 604.946.3131 seisales@sei-ind.com www.sei-ind.com Page 2 of 2...

Table of Contents