Download Print this page

Welbilt Frymaster PF50 CE Series Operation, Service And Parts Manual page 22

Portable filtration system

Advertisement

PF50 CE SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 6: TROUBLESHOOTING/SERVICE PROCEDURES
6.4.2 Replace Heater Strip (cont.)
7. 230VAC Filters: Disconnect the red wire
connected to the power supply cord (bobtail
connection) and the violet wire connected to
the Heater Indicator light on the switch panel.
8. Starting at the sump on the pan bottom,
install the new heater strip, using foil tape to
secure the heater to the pickup tube (see Step
3, this section).
9. Route the heater strip over the plumbing and
around the pump as previously removed in
Step 4.
10. Complete installation by securing strip with
foil tape. Reconnect the wire connections
disconnected in Step 7, this section.
Reassemble filter by reversing Steps 1-3, this
section.
6-6

Advertisement

loading