• A qualified service company should check the unit for safe and efficient operation on an annual basis.
• Gas piping shall be a certain size and installed to provide a supply of gas sufficient to meet the full gas input of
the equipment.
• A manual shut off valve should be installed upstream from the manifold within 4 ft. (1.2m) of the equipment and
in a position where it can be reached in the event of an emergency.
• Check entire gas piping system for leaks every so often. Using a gas leak detector or soapy water solution is
recommended.
• Install equipment under efficient exhaust hood with flameproof filters with a distance of no less than 4 feet
between the top of the equipment and the filters or any other combustible materials.
*Shipped setup for Natural Gas and includes a kit for conversion to LPG.
Pilot Outage
Improper burner combustion
Poor Ignition
MODEL
Natural Gas BTU/hr Input Rating
REL-SP-1
REL-SP-2

MAINTENANCE

Product Specifications
85,000
170,000
1. Pilot flame too low
2. Restriction in pilot orifice
3. Restriction in pilot valve
1. Improper ventilation
1. Insufficient gas input
2. Poor air-gas adjustment
3. Restrict ion in pilot orifice
4. Restrict ion in main burner ignition port
5. Restrict ion in control valve
6. Restrict ion in gas orifice
Propane Gas BTU/hr Input Rating
52,000
104,000
6
SP User Manual 0621
Qty of burners
1 outer+1 inner
2 outer+2 inner