Bosch BFL523MS0B User Manual And Installation Instructions page 19

Hide thumbs Also See for BFL523MS0B:
Table of Contents

Advertisement

¡ Do not install the appliance behind a decor-
ative door or the door of a kitchen unit.
There is a risk of overheating.
¡ Cut-out work on the units should be carried
out before installing the appliance. Remove
any shavings. Otherwise, the correct opera-
tion of electrical components may be ad-
versely affected.
¡ Only a licensed professional may connect
appliances without plugs. Damage caused
by incorrect connection is not covered un-
der the warranty.
WARNING ‒ Risk of injury!
Parts that are accessible during installation
may have sharp edges and may lead to cut-
ting injuries.
▶ Wear protective gloves
WARNING ‒ Risk of fire!
It is dangerous to use an extended power
cord and non-approved adapters.
▶ Do not use extension cables or multiple
socket strips.
▶ If the power cord is too short, contact Cus-
tomer Service.
▶ Only use adapters approved by the manu-
facturer.
15.2 Electrical connection
In order to safely connect the appliance electrically, fol-
low these instructions.
WARNING ‒ Risk of electric shock!
Incorrect installation is dangerous.
Only a qualified electrician may route the socket or
replace a power cable while taking into considera-
tion the applicable regulations.
Connect the appliance only to a correctly installed,
earthed socket.
If the plug is no longer accessible following installa-
tion, an all-pole isolating unit with a contact clear-
ance of at least 3 mm must be available on the in-
stallation side. Contact protection must be ensured
by the installation.
15.3 Scope of delivery
After unpacking all parts, check for any damage in
transit and completeness of the delivery.
15.4 Fitted units
Here, you can find notes on safe installation.
ATTENTION!
Any shavings may impair the function of electrical com-
ponents.
Carry out cut-out work on the units before installing
the appliance.
Remove the shavings.
¡ The minimum installation height is 850 mm.
¡ The installation cabinet must not have a back panel
behind the appliance.
¡ The ventilation slots and intake openings must not
be covered.
¡ Fitted units must be heat-resistant up to 90 °C, and
adjacent unit fronts up to 65 °C.
15.5 Installation dimensions in the upper
cabinet
Observe the installation dimensions and the safety
clearances in an upper cabinet.
15.6 Preparing the upper cabinet
Determine the wall thickness of the unit.
1.
An x-value is assigned to the wall thickness.
Note: The x-value corresponds to the distance
2.
between the lower edge of the connection plate and
the bottom of the fitted unit.
Screw the connection plate tightly into the upper
unit.
Installation instructions en
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bfl524ms0bBfl523mw0bBfl523mb0b

Table of Contents