Si00-778
Step
3. Remove the PCB.
Loosen the screw on
1
the terminal board.
Cut the clamp.
2
Loosen the 2 screws of
3
the earth terminal.
4
Disconnect the 2
connectors of the
reactor.
Removal Procedure
Procedure
Reactor
Brown
White
The lead-free solder (PbF) is
used on PCB. When exchange,
use exclusive solder and
Terminal board
soldering gun.
(R7397)
(R7398)
(R7399)
(R7400)
Removal of PCB
Points