Contents Introduction ......................4 Safety Information and Notes ................5 Storage of this Manual ................... 5 Special Conditions for Safe Use ..............5 2.1.1 Class I Zone 0 ..................5 2.1.2 Class I Zone 1 ..................5 2.1.3 Class II Zone 21 ..................5 List of Notes ....................
1 Introduction The iTAG100-7, iTAG100-7-CB, iTAG100-7D, iTAG100-7D-CB are MET Canada approved, intrinsically safe versions of the Stanley T2 Tag. This is the most advanced Wi-Fi based Active RFID tag on the market, from the company that originated the Wi-Fi tag industry. The device is a small, long-life Wi-Fi based active RFID device that can be placed on any asset, allowing the Stanley system to locate assets that are not Wi-Fi enabled.
2 Safety Information and Notes 2.1 Storage of this Manual Keep this user manual safe and in the vicinity of the product. All persons required work on or with the product should be advised on where the manual is stored. 2.1 Special Conditions for Safe Use 2.1.1 Class I Zone 0 None...
Any repairs or replacement of parts MUST be performed by the manufacturer or its nominated sub-contractor or agent. 2.3 Class and Zone Approval Information The iTAG100-7, iTAG100-7-CB carry the following approval: MET Canada Class I, Zone 0, Ex ia IIB T6..T4 Ga Class I, Zone 1, Ex ia IIC T6..T4 Gb...
3 Installation and Setting-to-Work 3.1 Assembly and Disassembly The iTAG100 is provided ready assembled and should not be dismantled by the user. 3.2 Installation The iTAG100 should be mounted on the asset to be tracked, or worn by the person who is to be tracked.
4 Intended Purpose Usage Important Before setting the units to work, read the technical documentation carefully. Important The latest version of the technical documentation or the corresponding technical supplements is valid in each case. Important For the installation, maintenance and cleaning of the units, it is absolutely necessary to observe the applicable regulations and provisions concerned with explosion protection (IEC 60079-0, IEC 60079- 11, IEC 60079-14, CEC 18).
The iTAG100 will require additional protection if it is installed in a location where it may be subjected to damage. 5 Type Codes Type Code Description iTAG100-7 MET Canada Certified, Class I Zone 0 IIB T4,T5,T6, Listing E113811 Class I Zone 1 IIC T4,T5,T6, Listing E113811 iTAG100-7-CB...