Download Print this page

Cerio POE-OSP User Manual page 2

Gigabit ethernet poe pass-through outdoor surge protector

Advertisement

Product Application
Installation
Distance between installations
The cabling distance between the surge protector (POE-OSP) and the
protected device should be less than 1 meter.
The closer the POE-OSP is installed to the protection device, the more
effective it is for the protection device.
『DEVICE』Port
This port support transmit up to 74 Watt four pair of PoE power is used
for connecting the unit to the outdoor Ethernet device it will be protecting
(e.g. PoE access point or PoE IP camera).
『LINE IN』Port
This port support receive up to 74 Watt four pair of PoE power from that
device is used for connecting the unit to the outside network.
Device locked on the wall
You can use the packaged screw
attachment for installation
Connect a ground wire
The unit must be grounded, before connecting the grounding wire size,
We recommend using a 12~18 Gauge (AWG) (copper wire diameter) size
for the grounding cable.
Ground wiring length 7.5 meters
Ground wiring length 15 meters
Ground wiring length 30 meters
Ground wiring length 60 meters
Please refer to the following how to ground the POE-OSP.
First remove the grounding screw on the side of the unit. Place the
ground wire of the connected O-type terminal on the ground screw hole.
Insert and tighten the grounding screw firmly to secure the grounding
wire and the ring to the device. Connect the other end of the ground wire
to a ground rod or your ground source.
Note: Proper installation is required for the grounding wire to
achieve its highest surge capability.
Please use 18 Gauge (AWG) size
Please use 16 Gauge (AWG) size
Please use 14 Gauge (AWG) size
Please use 12 Gauge (AWG) size
V1.4

Advertisement

loading