4. Connection and Operation
4. 1
Connection
・Connect the motor according to the "wiring diagram" shown below.
・Insulate all the wire connections, such as the connection between the motor and the capacitor connection.
Capacitor caps are available as an option to insulate capacitor connection.
■ Wiring diagram
The motor rotates in a clockwise (CW) and counterclockwise (CCW) direction (viewing the motor from the side with the output shaft).
Motor type
Out put power
6W〜40W
60W, 90W
[6W〜25W type]
No. of
Single-phase
Switch
100V
SW1
AC125V
3A
or more
SW2
[40W〜 90W type]
No. of
Single-phase
Switch
100V
SW1
AC125V
5A
or more
SW2
SW1 emits sparks when turned on and off. In order to protect the relay contacts,
CR circuit (
Ro = 5〜200Ω
Co = 0.1〜0.2μF
Option of the ORIENTAL MOTOR's surge absorber is available.
Optional product name EPCR1201-2(sold separately)
Note: In case of 60W and 90W type, When removing the sheath of the cable, be careful not to damage the inside lead wire.
4
Single- phase Motor
SW2 CCW
CW
Line
Ro
Co
ON
SW1
ON
Ro
Co
SW2 CCW
CW
Line
Ro
Co
ON
SW1
ON
Ro
Co
Specification
Single-phase
200V
AC250V 1.5A
AC250V
1.5A
or more
Specification
Single-phase
200V
AC250V 5A
AC250V
5A
or more
) must be connected.
200WV
CCW
CW
White
Gray
Motor
Black
Yellow
Magnetic
Yellow
Brake
Capacitor
CCW
CW
White
Yellow
Motor
Black
Orange
Magnetic
Orange
Brake
Capacitor
Three-phase
Note
200V
Switched Simultaneously
or more
−
−
Three-phase
Note
200V
Switched Simultaneously
or more
−
−
Three- phase Motor
Line
Ro
Co
(U)
Black
R
(V)
Gray
S
(W)
White
Ro
Co
T
Yellow
SW1
Yellow
Ro
Co
Line
Ro
Co
(U)
Black
R
(V)
Yellow
S
(W)
Ro
Co
White
T
Orange
SW1
Orange
Ro
Co
CW
Motor
Magnetic
Brake
CW
Motor
Magnetic
Brake