1. APPLICATIONS
1) It is applicable to household water supply, equipment sup-
port, well water lifting, pipeline pressurization, garden watering,
vegetable greenhouse watering, fish farming and poultry
raising, etc.
2) Transfer clean water and other non-corrosive liquids with
low viscosity; do not transport inflammable, explosive, gasified
liquids and liquids containing solid particles or fibers. The PH
value should be within 6.5-8.5.
Remark:
This series of pump could be transformed into automatic water
pump, which is realized through external automatic plant that
is composed of pressure switch, pressure tank, etc. Function
features of the automatic pump are as follows: when the power
is on, turn on the water tap and the pump will start working
automatically; when the water tap is turned off, the pump will
stop working automatically. If a water tower is used along with
the automatic pump, connect to the upper limit switch and the
pump will start or stop working automatically with water level
in the water tower.
2. MODEL DESCRIPTION
PEP 05 A 16 S
Features S=Standard
Hertz 5=50hz, 6=60Hz
Phase 1=Single phase, 3=Three phase
Voltage A=115V, C=230V, F=110/220V
HPx10
Series Peripheral Pump
3. TECHNICAL DATA
Max. flow: 90Umin
Max. head: 1 OOm
Output power: 0.3-2.2kW
Max. Suction: 9m
Insulation grade:IP44
Protection grade:F
Max. ambient temperature:+40
Max. liquid temperature:+40
4. IMPLEMENTATION STANDARDS
IEC/EN 60335-1 Household and similar electrical appliances-
-safety Part1: General requirements.
IEC/EN 60335-2-41 Household and similar electrical
appliances--safety Part2-41: Particular requirements for pump.
2006/95/EC Low voltage directive
INSTALLATION AND OPERATING INSTRUCTIONS
5. SAFETY PRECAUTIONS
1. To ensure normal and
safety operation of the
electric pump, read manual
carefuly before use.
3. Do not touch the electric
pump while working; do not
wash, swim near working
area or let livestock into the
water to avoid accidents.
JCP-JSP
Self priming jet cast iron pumps
ON
OFF
1
1
0
0
2. The electric pump should
have reliable grounding to
prevent short circuit; for
safety, leakage protection
switch should be equipped
and be careful no to wet the
power plug; socket should be
connected in damp - proof
area.
l
M a n u a

Advertisement

loading

Summary of Contents for Pearl JCP

  • Page 1 JCP-JSP Self priming jet cast iron pumps INSTALLATION AND OPERATING INSTRUCTIONS Before installation, you should carefully read this manual, and pay attention to safety cautions and instructions in this manual. Our factory is neither responsible for nor is reliable for paying compensation for personal injury, pump damage and other property losses caused by violation of safety cautions.
  • Page 2: Product Structure

    4. Avoid splashing pres- 9. Ensure the pump will sured water to the electric not be accidently turned pump as well as prevent on while installing and the pump immersed by maintaining; if not used water. for a long time, cut off the power first and then tum off valves in inlet and outlet of the pump.
  • Page 3: Electrical Connection

    Incorrect Installation Diagram Max. water temperature: + 40 Min. Water temperature: +4 1. For pump installation, the inlet pipe should be as short as B. Installation Precautions of the outlet pipeline possible with the least turnings. The pump should be installed in ventilated and dry environment.
  • Page 4: Start-Up And Maintenance

    4) Check rotation of the motor (three-phase motor) Attention: 5) Check whether operation of the electric pump is normal, rotation is correct, which could be observed from the fan blade 1) The pump chamber should be filled with water before first terminal, e.g.
  • Page 5 ... troubleshooting cont. PROBLEM POSSIBLE CAUSE SOLUTION Incorrect pump type Select suitable pump The inlet pipeline is too long or with too Apply the pipe with the stipulated diameter, and many bends, pipe diameter is not selected Insufficient pressure make the inlet pipe short. as required.