Page 1
User Manual Swing Door Motor SDO-PK23 www.esslsecurity.com...
Page 2
WARNING TO THE INSTALLER GENERAL SAFETY OBLIGATIONS 1) CAUTION! For personal safety it is important to follow all the instructions carefully. Incorrect installation or misuse of the product may cause serious injury to people . 2) This product must be installed, debugged and maintained by professional and qualied personnel.
1. Main Parts PK23,swing door opener Power supply 1pcs Support 1pcs Adaptor arm 1pcs Long&Short Pin one each Circlip 12pcs Straight arm 1pcs Bent arm 1pcs φ12 Flat washer φ8 8pcs Anti-water joint 1pcs Hexagon socket head cap screws Flat key 1pcs Flat washer φ12 6pcs M8x20 6pcs Hexagon socket button head screws...
3.Technical Data Power supply 100V~240V AC Power of motor 24VDC/40W Rpm of motor 3000rpm±10% Open/close time 3-10S(adjustable) Current of motor 2.8A±10% Maximum door width 1 00mm Maximum door weight 15 Kg Working temperature -20℃~50℃ Maximum opening angle 20°~90° adjustable 4.Features * Pull or push to activate the door opener operation.
5.1 Installation diagram Connect output power 24V ² by 2-core wire 1.5mm Connect input power 100-240V ² by 3-core wire 1.5mm Connect output power 24V ² by 2-core wire 1.5mm Very Important Notice! Both the door frame and the door must be rm and strong. Ensure the xed points that the door opener installed on the door frame and the door are rm and reliable, and will not loosen during operation! 5.2 Installation steps of PULLING OPENER...
Page 6
5.2.2 Installation of OPENER Fix braket by M8x20mm screws Top cover +sping washer +at washer Led cover 5.2.3 Installation of adaptor arm Adaptor arm 6×20mm Flat pin 2pcs Fix at pin,then install adaptor arm as arrow direction.
Page 7
5.2.4 Installation of top cover 2-M5×25mm( Hexagon socket head cap screws ) ( +Spring washer ) Top cover Install top cover as arrow direction 5.2.5 Connet arms group Straight arm Long pin Bent arm Flash washer Circlip connect straight arm and bent arm as picture 5.2.6 Installation of arms group Braket Short pin...
Page 8
5.2.7 Installation of arms group to adaptor arm There are 3 installation holes, fix 2 holes by 2pcs M8X20mm scews and flat washer as arrow position to connect arms group and adaptor arm. Front install Rear install 450±20(mm) 500±20(mm) Rear install Installation Front install 5.2.8 Open the cover...
Page 9
5.2.9 Install the LED cover and connect wires. Connect power cable and led cable to PCB board, please refer to page Fix led cover by 2pcs M5X10mm screws. Led cable 24V power cable 2-M5×10mm (Screws and spring washers) 5.2.10 Assemble the cover.
6.2 Wiring diagram Notice: Dene the door that opens ahead but and closes behind as the MASTER DOOR. Dene the door that opens behind but closes ahead as the SLAVE DOOR. All signals are accessed by the MASTER and send out instructions.(Refer to 6.1 DIP switch settings for dual-door mode.) The SLAVE needn’t learn Transmitter.
Page 12
7. Dip switch, learning code and mode setting 7.1 Definition of Dipswitches and Transmitter (single door) (dual door) (MASTER) (SLAVE) (close (close clockwise) counterclockwise) OPEN STOP CLOSE Important:There is only a "learn" button on the door opener control board.Before setting on the Transmitter, it must be coded. For a dual-door,only the MASTER OPENER code Transmitter.
Page 13
* Functions of Buttons OPEN: ①Open the door. ②To be set to normally open mode after being pressed and hold for 3 seconds . ③Increase parameter value during setting. CLOSE: ①Close the door. ②Restore automatic close function after being pressed in normally open mode. ③ Decrease parameter value during setting.
Page 14
7.4 Parameters setting 7.4.1 Denitions Factory range description Menu code functions settngis Open speed 15-70 Close speed 15-70 The larger the value, the faster the speed Open slow speed 10-50 Close slow speed 10-50 Open deceleration range 15-99 The larger the value, the larger the slow-moving range.
Page 15
7.4.2 Setting Press the SET button on the Transmitter and hold till displaying P1 to enter Setting process.Refer to the following steps and the 6.3.1 Denitionstable for parameter setting. After setting the parameters, keep pressing the SET or STOP to save and exit. default Press and hold SET for 3 seconds OPEN...
Page 16
STOP OPEN Mode of opening CLOSE STOP OPEN Start interval CLOSE STOP OPEN Resistance sensitivity CLOSE STOP OPEN Vigorously close door mode CLOSE STOP OPEN Duration of vigorously closing CLOSE STOP OPEN strength CLOSE STOP OPEN Remote control mode CLOSE STOP OPEN Infrared protector mode...
8.Trouble shooting Trouble shooting trouble ·Check the terminal wiring. ·Check the power-on switch. All LED indicators are ·Check the fuse. off after power on. ·Measure the transformer’s input and output. ·Check the power chip on the control board. Door opening and closing are ·Check the dip-switch 3.
Need help?
Do you have a question about the SDO-PK23 and is the answer not in the manual?
Questions and answers