Summary of Contents for Xtramus LES-5160

  • Page 1 LES-5160 Cat-5e Simulator USM Ver 1.2...
  • Page 2: Foreword

    Copyright Copyright © 2019 Xtramus Technologies, all rights reserved. The information contained in this document is the property of Xtramus Technologies. No part of this publication shall be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, without the prior written permission of Xtramus Technologies.
  • Page 3: Revision History

    Revision History Date Version History 2014/07/23 First version. 2014/12/03 Add the description of the three length simulation modes. 1. Change header and footer pictures. 2019/05/05 2. Modify the description about cable length setting.
  • Page 4: Table Of Contents

    Revision History ..........................3 1. LES-5160 Overview ........................5 1.1. General Descriptions of LES-5160 .................. 5 1.2. Features, Key Advantages, and Main Applications of LES-5160 ........6 1.3. LES-5160 Functions Overview ..................7 1.3.1. LES-5160 Chassis ......................7 1.3.2. LES-5160 Front Part ....................8 1.3.3.
  • Page 5: Les-5160 Overview

    Combined with XLE series modules, LES-5160 cable length simulator provides RJ45 interfaces, which can support the protocols such as 10Base-T, 100BASE-TX, and 1000BASE-T, thus making your network verification system more complete.
  • Page 6: Features, Key Advantages, And Main Applications Of Les-5160

    1.2. Features, Key Advantages, and Main Applications of LES-5160 Features  Simulate Ethernet cable Cat-5e in different lengths  Support easy-to-access Management Webpage, allowing users to view system status, set the simulating length and upgrade firmware/FPGA  Multiple LES-5160 chassis can be cascaded for system management ...
  • Page 7: Les-5160 Functions Overview

    LES-5160’s chassis consists two parts: Front Part and Back Part. LES-5160 Chassis Overview LES-5160 has 16 slots for installation of modules. Each module card provides the simulation of one cable Cat-5e line. Besides, the Front Part provides 3 slots for Front Part installing the fan module, CASC module and management module.
  • Page 8: Les-5160 Front Part

    1.3.2. LES-5160 Front Part As mentioned in “1.3.1. LES-5160 Chassis”, LES-5160 has 16 slots for installing cable Cat-5e simulation modules and 3 slots for installing the Fan, CASC and management module. Please see the sections down below for more detailed information/specification for LES-5160 and the modules.
  • Page 9: Modules

    XLE-CASC Cascade multiple LES-5160 chassis Modules for Cat-5e simulation. These Cat-5e Simulation XLE-C5E Cat-5e simulation modules can be installed Modules in slot 2~17 and support hot-swap. Please see the sections down below for more detailed information regarding to LES-5160 modules.
  • Page 10: System Module- Xle-Sfan

    1.3.3.1. System Module– XLE-SFAN The XLE-SFAN is delivered with the LES-5160 chassis, and shall be installed on the Fan slot located on the far left side of LES-5160 chassis. This module provides ventilation for the LES-5160 chassis. Interface Ports CTRL + PWR...
  • Page 11: System Module- Xle-M667

    1.3.3.2. System Module– XLE-M667 The XLE-M667 is delivered with the LES-5160 chassis, and shall be installed on the Mgm slot located on the far right side of LES-5160 chassis. This module allows you to manage LES-5160 chassis via the Management Webpage.
  • Page 12: System Module Card - Xle-Casc

    LES-5160 chassis. To cascade the LES-5160, please inter-connect the Up port or Down port of the chassis with the RJ45 cables. For the cascaded chassis, you can manage all the chassis through one integrated web page.
  • Page 13: Cat-5E Simulation Module - Xle-C5E

    1.3.3.4. Cat-5e Simulation Module – XLE-C5E XLE-C5E Front Panel Specification Port A RJ45 Interface Port B RJ45 Data Transfer Rate 1000 Mbps Ethernet Mode 10Base-T, 100BASE-TX, and 1000BASE-T LED Status Green ON XLE-C5E is powered on. Green OFF XLE-C5E is powered off. XLE-C5E is booting properly and is ready for Green ON tests.
  • Page 14: Les-5160 Back Part

    1.3.4. LES-5160 Back Part As mentioned in “1.3.1. LES-5160 Chassis”, LES-5160’s back part includes 3 different slots for installing the DC module, AC module and Fan module. LES-5160 Back Part Description It is a fan module pre-installed in the back part of LES-5160 XLE-RFAN chassis.
  • Page 15: Xle-Rfan

    1.3.4.1. XLE-RFAN The XLE-RFAN consists of two fans as shown in the picture below. After installing XLE-RFAN, the Management Web Page will show the operation of XLE-RFAN, please see the 3.1.4. LES-5160 Management Webpage – Management for more information.
  • Page 16: Xcp-A1W-300

    1.3.4.2. XCP-A1W-300 XCP-A1W-300 is a power module providing power source of 300W AC Redundant SPS (Vin 90~240VAC). The Power Jack of XCP-A1W-300 is a Male IEC 320 Receptacle. To activate XCP-A1W-300 & XLEP-AC-100, just turn on/off the O/I button after connecting a power source cable in Male IEC 320 Receptacle.
  • Page 17: Les-5160 Installation

    LES-5160 is a chassis with 16 slots for installation of Cat-5e simulation modules. Installing LES-5160 is very easy and simple: all you have to do is to plug the proper UTP cables into the LES-5160 ports like a general Ethernet switch without any extra configurations. However, selecting the proper physical media and applications in your network environment is crucial when installing LES-5160.
  • Page 18: Hardware Installation

    Please follow the steps shown below for a better understanding on how to install the hardware of LES-5160. 2.2.1. Bracket installation Steps for installing a Bracket in LES-5160 First of all, you must have an Empty Slot for the Installation of a Bracket.
  • Page 19 After attaching the Bracket’s Latch on the internal face of Chassis’ Latch, let this point be a fix central rotation point and push the bottom part of Bracket into LES-5160. Lock the Captive Screw into the LES-5160 to fix the Bracket into LES-5160.
  • Page 20: Modules Installation

    2.2.2. Modules Installation Steps for installing a XLE-C5E module in LES-5160 Aim the border side of a Cat-5e simulation module with the LES-5160 internal slide road, and push this module into LES-5160. Please, make sure if the XLE-C5E module is well fixed into LES-5160 by pushing the bracket of the module into LES-5160.
  • Page 21 Steps for installing a XLE-C5E module in LES-5160 Lock the Captive Screw into the LES-5160 to fix the module into LES-5160.
  • Page 22: Power Module

    Power Module into the slot. After the Bracket of the Power Module reaches the LES-5160, lock the captive screw into LES-5160 as shown by arrows 4 and 5. Note: The XCP-A1W-300 doesn’t support hot swap. Please don’t remove Power...
  • Page 23: Fan Module

    LES-5160 chassis. This module card provides ventilation for the LES-5160 chassis. Warning: The CTRL + PWR port and PWR port are preserved for future use. Please do not conduct any cable connections, or LES-5160 may be seriously damaged.
  • Page 24: Les-5160 Management

    Before accessing to LES-5160’s management webpage, please connect the network interfaces between the PC and the manage card “XLE-M667” and configure the IP address for LES-5160. Please refer to the picture down below to configure the IP address. The default IP address is 192.168.1.8.
  • Page 25: Accessing Les-5160 Management Webpage

    3.1.1.1. Access with IP address To access LES-5160’s management webpage, please open your web browser, and type in LES-5160’s default IP address (192.168.1.8) in the web browser’s URL field. If you’ve changed LES-5160’s IP address, please input the IP address you’ve changed to.
  • Page 26 Go to Network. You can see the “LES-5160” device is listed. If you cannot see the “LES-5160”, please turn off your firewall and then try again. Double click the icon of “LES-5160” to enter the management webpage.
  • Page 27 Contact: Contact information of Xtramus Co.Ltd. Model Name This field displays the model name “LES-5160”. The Setting Options contains options for LES-5160 settings, information, and statistics, which can be divided into:  System: You can view system information here in this field.
  • Page 28: Les-5160 Management Webpage - System

    The management page provides two information interfaces: System Information and Module Information. You can access to the two interfaces by click the links at the upper left corner. 3.1.3.1. System Information System Information displays LES-5160’ system information including: System Information Model Name The model of the device “LES-5160”...
  • Page 29: Module Information

    MAC address. 3.1.3.3. IP settings IP Settings: Allows you to set how LES-5160 will acquire its IP, subnet mask, and gateway addresses. Also, you could input these addresses manually here. Click IP Settings, the following screen appears.
  • Page 30 IP Settings You can choose how LES-5160 acquires its IP, subnet mask, and gateway addresses. There are two modes available:  Static: You have to input LES-5160’s IP, subnet mask, and Mode gateway addresses manually in the fields down below.
  • Page 31: Les-5160 Management Webpage - Management

    There are 3 options available for Management, including Chassis Overview, Cable Length Settings, and Characteristic Chart. 3.1.4.1 Chassis Overview This page can display the status of the modules installed in the LES-5160 chassis and the cable length settings. The page is shown as follows. Chassis Overview...
  • Page 32: Cable Length Settings

    3.1.4.2. Cable Length Settings This page is used to individually set the simulation cable length for each module. There are three modes to choose, which are Bypass, Short and 100m, respectively regarding to short by relay, 1~3 meters and 100 meters. The page is shown as follows. Click Apply to make your settings here effective.
  • Page 33: Les-5160 Management Webpage - Maintenance

    This mode is to upgrade the firmware of management card. Management Card Click the Browse… button to choose the firmware file you would like to Browse… upgrade. LES-5160’s firmware files are in the format of “*.bin”. Apply Click this button to start upgrading LES-5160’s firmware. b. Single Subcard This mode is to upgrade the firmware of a single XLE-C5E module.
  • Page 34: Save Changes

    Click the Browse… button to choose the firmware file you would like to Browse… upgrade. LES-5160’s firmware files are in the format of “*.bin”. Click this button to start upgrading LES-5160’s firmware. And then the firmware Apply of the selected modules will be upgraded in sequence.
  • Page 35: Factory Defaults

    3.1.5.3. Factory Defaults Factory Defaults Restore You can set all LES-5160’s settings to default by clicking the “Restore” button. 3.1.5.4. System Reboot System Reboot You can reboot LES-5160 by clicking the “Reboot” button. Please note that all Reboot unsaved settings will be lost after system reboot.
  • Page 36: Les-5160 General Specifications

    4. LES-5160 General Specifications Model LES-5160 Slot 16 Slots for Installing XLE Series Modules Dimension 441 mm x 310 mm x 88 mm Temperature Operating: 0 C ~ 40 C (32 F ~ 104 Storage: 0 C ~ 50 C (32 F ~ 122 ...