LUBRICATION OIL
Use only SF (SE) quality oil according to the API sys-
tem. Volvo Penta's lubricating oil for gasoline engines
complies with these requirements and can therefore be
recommended for use. Refer to viscosity in the Techni-
cal Data if any other type of lubricating oil is used.
RUNNING IN
A new marine engine requires careful running in during
the first 20 hours of use. You should therefore avoid run-
ning the engine at maximum load during this period. A
higher consumption of oil during the running in period is
normal. Check the oil level more regularly during the run-
ning in period for this reason.
SPARE PARTS
WARNING! Components in the electrical sys-
tem, the ignition system and the fuel system on
Volvo Penta products are designed and built to
minimize the risk of explosion and fire.
The use of non-approved parts, which do not
comply with the above requirements, may result
in an explosion or fire on board.
WARRANTY INSPECTION (NOT
USA)
The warranty inspection is carried out after a running
time of between 20 and 50 hours or within 120 days after
delivery. The inspection is carried out by an authorised
Volvo Penta workshop.
FIRST INSPECTION (USA)
A first inspection should be carried out by an authorized
Volvo Penta dealer within 20 and 50 hours or 120 days
after delivery. This inspection is at the owner's expense.
OIL CHANGES
The oil and oil filter are changed during the 20 hour in-
spection. Refer also to Checks and Servicing.