11. Safety devices

Type of
protection
Circuit
Current fuse (PCB*)
protection
Fan motor
Thermal protection program
protection
Thermal protection program
(Discharge temp.)
Compressor
protection
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY mode)
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
- 50 -
Model
AOHG18KMTA
250 V, 25 A
250 V 5 A
250 V, 3.15 A
100±15°C
Fan motor stop
95±10°C
Fan motor restart
110°C
Compressor stop
After 7 minutes
Compressor restart
-20 °C
Compressor stop
-15 °C
Compressor restart
Compressor restart
AOHG24KMTA
-15 °C
Compressor stop
-10 °C