Fan kit

Advertisement

SIT Valve
-
Connect the black, white and red wires with 1/4 in. female connectors from fan control module to appliance junction
box as shown in Figure 12.
-
Connect the black ground wire with the ring terminal to the TP screw on the valve (center).
-
Connect blue jumper wire between fan control wire (black with white stripe) and valve. Plug 1/4 in. female end of blue
jumper wire to the back side of valve wiring block marked TH.
Figure 12 - SIT Wiring Diagram
6. Recommended Fan Control Set-up Procedure
Note: The test sequence works only during the first (approximately) seven minutes after power-up.
With burner and pilot extinguished:
Turn control knob clockwise to activate control.
Press and hold test button on the control module.
-
Fan will turn on.
-
Adjust fan speed to the desired speed using the control
knob.
-
Release test button. Fan will stop.
SIT
Valve
Fan
Black
Control
Module
Hearth & Home Technologies • GFK4B Fan Kit • 4016-095 Rev N • 04/21
Wall
Switch
White
Red
Black
Fan control is now fully operational and will operate
automatically each time appliance is used.
Operates with APPROXIMATELY a 7-minute delay to turn
on and a 12-minute delay to turn off.