Fan kit

Advertisement

Dexen Valve (IPI) * (wiring diagram when using junction box with spade connectors)
-
Connect the black, white and red wires with 1/4 in. female connectors from fan control module to appliance junction
box as shown in Figure 10.
-
Connect the black ground wire from the fan control module to the appliance.
-
Remove the green ignition control wire from the valve.
-
Connect the black with white stripe wire with 3/16 in. piggyback connector from fan control module to valve.
-
Connect green ignition control wire to piggyback connector on black with white stripe fan control module wire.
Figure 10 - Dexen (IPI) Wiring Diagram
*Includes Intellifire-Plus when using RC100. Fan timer. Not used with RC200 or RC300.
Dexen Valve (IPI) * (wiring diagram when using junction box without spade connectors)
-
Connect the black, white and red wires with 1/4 in. female connectors from fan control module to wire assembly as
shown in Figure 11.
-
Connect the black ground wire from the fan control module to the appliance.
-
Remove the green ignition control wire from the valve.
-
Connect the black with white stripe wire with 3/16 in. piggyback connector from fan control module to valve.
-
Connect green ignition control wire to piggyback connector on black with white stripe fan control module wire.
-
Plug receptacle from wire assembly into junction box.
Figure 11 - Dexen (IPI) Wiring Diagram Without Spade Connectors
4
Dexen
Valve
Fan
Black
Control
Module
Ground
Dexen
Valve
Fan Control
Module
Black
Ground
Hearth & Home Technologies • GFK4B Fan Kit • 4016-095 Rev N • 04/21
White
Red
Black
Black
Red
Black
Black
To Receptacle
On Junction Box