FIGURE 13: Dimensions
Table 3: Cabinet and Duct Dimensions
Nominal
BTUH (kW)
3
Input
CFM (m
60 (17.6)
1200 (34.0)
80 (23.4)
1200 (34.0)
80 (23.4)
1600 (45.3)
100 (29.3)
1600 (45.3)
100 (29.3)
2000 (56.6)
120 (35.1)
2000 (56.6)
SECTION III: FILTERS
FILTER INSTALLATION
CAUTION
!
All filters and mounting provision must be field supplied. All installa-
tions must have a filter installed.
All applications require the use of a field installed filter. All filters and
mounting provision must be field supplied.
Filters must be installed external to the furnace cabinet. DO NOT
attempt to install filters inside the furnace.
NOTICE
Single side return above 1800 CFM is approved as long as the filter
velocity does not exceed filter manufacturer's recommendation and a
transition is used to allow use on a 20x25 filter.
Table 4: Recommended Filter Sizes (High Velocity 600 FPM)
CFM (m³/min)
Cabinet Size
1200 (34.0)
B
1600 (45.3)
C
2000 (56.6)
C
2000 (56.6)
D
1. Air velocity through throwaway type filters may not exceed 300 feet per min-
ute (91.4 m/min). All velocities over this require the use of high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one side return with a transition to allow use of a 20x25 filter.
Johnson Controls Unitary Products
Cabinet
Size
/min)
A (in)
B
17 1/2
B
17 1/2
C
21
C
21
C
21
D
24 1/2
Side (in)
Bottom (in)
16 x 25
16 x 25
16 x 25
20 x 25
(2) 16 x 25
20 x 25
(2) 16 x 25
22 x 25
Cabinet Dimensions (Illustrated in Figure 13)
A (cm)
B (in)
B (cm)
44.4
16 3/8
41.6
44.4
16 3/8
41.6
53.3
19 7/8
50.5
53.3
19 7/8
50.5
53.3
19 7/8
50.5
62.2
23 3/8
59.4
SIDE RETURN
Locate the "L" shaped corner locators. These indicate the size of the cut-
out to be made in the furnace side panel. Refer to Figure 14.
FIGURE 14: Side Return Cutout Markings
Install the side filter rack following the instructions provided with that
accessory. If a filter(s) is provided at another location in the return air
system, the ductwork may be directly attached to the furnace side
panel.
IMPORTANT
Some accessories such as electronic air cleaners and pleated media
may require a larger side opening. Follow the instructions supplied
with that accessory for side opening requirements. Do not cut the
opening larger than the dimensions for the "Optional Return Air Cut-
out" shown in Figure 13.
1083286-UIM-H-0817
Approximate
Operating Weights
C (in)
C (cm)
Lbs (kg)
13 1/4
33.7
122
14 3/4
37.5
126
16 1/2
41.9
136
18 1/4
46.4
142
18 1/4
46.4
145
21 3/4
55.2
156
Front of
Furnace
Side of
Furnace
Corner
Markings
9