Finish Requirements; Installation Components - Intertherm DELUXE 42 Installation Instructions Manual

42" wood burning fireplaces
Table of Contents

Advertisement

FINISH TO YOUR TASTE
There are a wide variety of "finished looks" for
these fireplaces, from formal wall decor with
elaborate mantels to rustic wood paneling or
warm brick facings.
Only noncombustible materials like stone, tile,
brick, etc., may overlap the black front facing.
Do not extend these materials beyond the black
facing and into the firebox area. Be sure not to
interfere with the installation and operation of
glass doors or block the upper or lower grilles.
Seal all joints between the black facing and wall
surrounds to prevent air intrusion. Use non-
combustible caulking material only to seal the
black metal facing to the surround material on
the finished wall.
Combustible materials may project beyond the
sides of the fireplace opening as long as they
are kept within the shaded areas illustrated in
Figure 48 .
Combustible
Materials
Allowed In
Shaded Area
"Safe Zone"
9"
45°
12"
Min. Distance To
9"
Protected Side Wall
Min. Distance To
12"
Unprotected Side Wall
Figure 48
Shipping Weight
18

INSTALLATION COMPONENTS

The following items are available for use in the
installation of this appliance.
Chimney Section
Fireplace
Adjustable Chimney Pipe Kits
1"
Storm Collar
12 Pack
201 lbs.
Locking Band
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Flashing
63L10
FTF8-12
63L13
FTF8-18
63L14
FTF8-36
63L15
FTF8-48
Adjustable Firestop/Thimble
HO323
FM8-PK1
Offset/ Return
Package (30°)
94L77
FSC
63L60
FLB
Thimble Extension 26"
0-6/12
63L38
6/12-12/12
63L39
HO325
FM8-AT1
63L22
FTF8-ES30
91L46
F8-TE26
F8F6
F8F12