Index 1. INTRODUCTION ........................1 2. GENERAL CHARACTERISTICS....................1 2.1. Electrical characteristics ..................... 1 2.1.1. Electrical characteristics of the DN-107/P displays............. 1 2.2. Dimensions and fixing of the displays ................2 2.2.1. Dimensions of the displays DN-107/3 ................2 2.2.2.
Page 4
4.4.1. Using functions BCD, tachometer. binary or digit by digit.......... 16 4.4.2. Using functions counter or chronometer ..............17 4.4.3. Parameters to define the colour................. 18 4.4.4. Work with only one colour..................19...
Binary. For displays up to 4 digits. Displays the decimal value of binary codes represented by the 14 inputs. Maximum value: 9999. The size of digits of DN-107P is 57mm. The viewing distance from 30m to 120m, is one of the most interesting characteristics.
CARACTERÍSTICAS GENERALES CAPÍTULO 2 2.2. Dimensions and fixing of the displays 2.2.1. Dimensions of the displays DN-107/3 All the measurements are in millimeters 2.2.2. Dimensions of the displays DN-107/4 All the measurements are in millimeters Display series DN-107P...
CAPÍTULO 2 CARACTERÍSTICAS GENERALES 2.2.3. Fixing of the displays Fixing plate 150/400/600 All the measurements are in millimeters DN-107P displays series...
The degree of protection of displays DN-107P, is IP41, meaning that they are protected against penetration by solid foreign objects of a diameter of about 1mm and against the vertical fall of water droplets.
4.3 “Functions”. The inputs power supply must be between 12V and 26V CC with a maximum wave of 500mV. Surpassing these values can damage the display. The auxiliary output can supply up to 180mA Display series DN-107P...
The left one when the decimal dot is activated in 2 digit displays. In 3 or more digits displays the third digit starting from the right. 4.2.2. Exit modify parameters In order to exit the sequence for modifying parameters, parameter F must be selected then press “*”. DN-107P displays series...
Parameter 7. S1: Activation and temporization conditions of output 1. Parameter 8. S2: Activation and temporization conditions of output 2. Parameter 9. FA: Value of multiplying or splitter factor. Parameter A. PU: Decimal point position. Parameter F. in: Exit programming parameters. Display series DN-107P...
Page 15
It can be from 0 to as many 9 as digits the display has. 4.2.4.6. Parameter 7. S1: Activation and temporization conditions of output 1. See 4.4.2 “Using functions counter or chronometer” 4.2.4.7. Parameter 8. S2: Activation and temporization conditions of output 2 See 4.4.2 “Using functions counter or chronometer” DN-107P displays series...
Parameter 5. A1: Value of alarm 1. Parameter 6. A2: Value of alarm 2. Parameter 7. S1: Activation and temporization conditions of output 1. Parameter 8. S2: Activation and temporization conditions of output 2. Parameter F. in: Exit programming parameters. Display series DN-107P...
Page 17
The maximum value is 23h:59m or 59m:59s. 4.2.5.5. Parameter 6. A2: Alarm 2 value The maximum value is 23h:59m or 59m:59s. 4.2.5.6. Parameter 7. S1: Activation and temporization conditions of output 1. See 4.4.2 “Using functions counter or chronometer” DN-107P displays series...
4.2.6.4. Parameter 5.LI: Time without pulses limit. Adjust the maximum time between two impulses. If this time is surpassed, the display shows 0. The time is measured in seconds and the rank is between 1s and 99s Display series DN-107P...
Selects the decimal point position (the number of decimal digits). With a value of 0 no decimal digits will be shown. 4.2.8. Parameters of function 07 (Digit by digit) Function 07 has no parameters, excepting in displays with colour or serial line options. DN-107P displays series...
If not, they codify the digit’s position and E1, E2, E3 and E4 are the code of the value. The digit 1 is in the right of the display. Decimal point position Digit No point Point selection Digit point selection ºE5 Function Symbol º = 01 Value Space = 11 Value Display series DN-107P...
This data must be stable for 5ms. Final display value 4.3.2. Function 11. 8 bits multiplexed BCD Function 11 acts in the same way as the function 1, except the values (1110 = E) and (1111= F). See the table on previous page. DN-107P displays series...
Example. To display The inputs must be Point position 4.3.4. Function 12. Direct BCD. Function 12 acts in the same way as the function 2, except the values (1110 = E) and (1111= F). See the previous table. Display series DN-107P...
The power supply of the inputs should be between 12V and 26VCC and the inputs can be PNP, NPN or CONTACT. E1 Loads preset 1. E2 Loads preset 2. E3 Reset. E4 Increase the counter. E5 Decrease the counter. DN-107P displays series...
The power supply of the inputs should be between 12V and 26V CC and the inputs can be PNP, NPN or CONTACT. E1 Control Run = ON / Stop = OFF. E2 Reset E3 Loads preset 1 E4 Loads preset 2 E5 Increase = ON / Decrease = OFF. Display series DN-107P...
The input frequency is 100Hz. A little stable oscillator. 4 digits display. Parameter Value 2.FE 0001 1Hz input frequency 3.dl 0001 Display 1 when 1 Hz input frequency 4.EL Update value every 3s 5.LI Maximum time without pulses: 1s. 6.Pd Show 1 decimal 7.FA Without average factor DN-107P displays series...
Page 26
Parameter Value 2.FE 0004,5 4,5Hz input frequency 3.dl 16200 Display 16200 when 4,5 Hz input frequency 4.EL Update value every 8s 5.LI Maximum time without pulses: 2s. 6.Pd Without decimals 7.FA Average factor: 8 (40 samples average) Display series DN-107P...
Digit one is the one on the far right of the display. The decimal point cannot be configured. Input Function Incr. Digit 1 Incr. Digit 2 Incr. Digit 3 Incr. Digit 4 Decr. Digit 1 Decr. Digit 2 Decr. Digit 3 Decr. Digit 4 DN-107P displays series...
ON if Value > Parameter A1 No delay / No hysteresis ON if Value < Parameter A1 Delay 1s Always OFF Delay 2s Delay 4s Delay 6s Delay 10s Hysteresis = 2 Hysteresis = 4 Hysteresis = 8 Hysteresis = 12 Display series DN-107P...
SR1 is the state of the output 1. AL1 is the value of alarm 1. AL2 is the value of alarm 2. SR1 will be activated when the activation conditions have been accomplished. SR1 will be deactivated when the time has passed or when the activation condition is not accomplished. DN-107P displays series...
Colour if internal bit r2 or SR2 is ON. To change the colour push * key. Upon pressing + the next parameter is shown. Colour if internal bits r1 and r2 or SR1 and SR2 are ON. To change the colour push * key. Upon pressing + the next parameter is shown. Display series DN-107P...
Parameters 8.A1, 9.A2, 5.A1 and 6.A2 may have any value. Parameters nr, r1, r2 and r3 should have the same colour. Independently of work colour, the parameters set up always uses RED colour. DN-107P displays series...
Page 33
Severo Ochoa, 80 Polígono Industrial Font del Radium 08403 Granollers As the builder of the equipment of the LARTET brand: Modelo: DN-107P in all versions. We declare under our sole responsibility that the aforementioned product complies with the following European directives: Directive: LVD 2006/95/CEE Low Voltage Directive.