CLEAN COMFORT DV070 Installation And Operation Manual

CLEAN COMFORT DV070 Installation And Operation Manual

Ventilating dehumidifier

Advertisement

DEHUMIDIFIER
The Clean Comfort™ DV070 dehumidifier
performs multiple functions in a compact
enclosure: high-capacity dehumidification,
fresh air ventilation, and particulate filtration.
Dehumidification
The highly efficient DV070 dehumidifier
utilizes refrigeration to cool the incoming
air stream below its dew point. This cooled
and drier air is then reheated by passing it
over the condenser coil.
Fresh Air Ventilation (optional)
Fresh outdoor air may be ducted to the
dehumidifier. This provides fresh air to dilute
indoor pollutants and replenish oxygen
content in the building. The amount of fresh
air ventilation can be regulated by a variety
of dampers and controls in order to provide
desired ventilation rates.
Air Filtration
The DV070 features air filtration, using a
MERV-11 media filter, to improve indoor
air quality.
i
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. THIS GUIDE TO BE LEFT WITH EQUIPMENT OWNER.
IO-DV070
DV070 Ventilating
Dehumidifier
Installation and Operation Manual
WWW.CLEANCOMFORT.COM
Clean Comfort DV070
TS-1022 11/17 REV A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DV070 and is the answer not in the manual?

Questions and answers

Summary of Contents for CLEAN COMFORT DV070

  • Page 1: Introduction

    Air Filtration The DV070 features air filtration, using a MERV-11 media filter, to improve indoor Clean Comfort DV070 air quality. IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. THIS GUIDE TO BE LEFT WITH EQUIPMENT OWNER.
  • Page 2: Table Of Contents

    Daikin. © 2014 DAIKIN NORTH AMERICA LLC  Houston, Texas • USA Copyright Notice www.cleancomfort.com Copyright 2014, Daikin North America LLC All rights reserved. 1-855-239-2665 WWW.CLEANCOMFORT.COM IO-DV070...
  • Page 3: Safety Precautions

    Prior to installation of the DV070, the following consider- ations for selecting the location for this equipment DVP-4034739 8" Backdraft Gravity Damper for should be reviewed. The DV070 can be installed in a DV070 dehumidifier variety of locations to meet the owner's needs, and DVP-4034746...
  • Page 4: Installation Considerations

    Support Structure and Suspension • If used near a pool or spa; be certain there is NO Place the DV070 on supports to raise the base of the chance the unit could fall into the water, splashed unit 2.5” above the drain pan beneath it. Do not place...
  • Page 5: Condensate (Water) Removal

    CONDENSATE REMOVAL The DV070 can be controlled by a variety of devices has touched the ground. This procedure will create a including the Clean Comfort DVP-4034748 or DVP-4034753 trap that ensures your unit drains correctly . See the digital controls. The controls are to be located remotely diagram below for further visual clarification.
  • Page 6: Ducting

    Fresh air may be brought into the home by connecting an tion of a separate supply duct from the DV070 to each insulated duct from outside the home to a tee connected isolated area is recommended.
  • Page 7: Fresh Air Ventilation

    DV070 in a central area of the home. Optional: frequency of ventilation should be based on the size and Duct the supply from the DV070 to an 8" x 8" x 8" tee/ occupancy of the residence. If you are unsure of your damper that is 20% open to the crawlspace if desired.
  • Page 8: Installation In A Home With No Existing Forced-Air Hvac System

    Figure 6: Converting DV070 to Vertical The preferred method of installation is to create a separate return to the DV070 in a central area of the Discharge Airflow home. Duct the supply from the DV070 to the air supply of the existing HVAC system. Connect an insulated duct from outside to the 8"...
  • Page 9: Quiet Installation

    The DV070 is controlled using five, labeled screw terminals: FAN = Fan control If the DV070 Dehumidifier is located in the area where DEHU = Dehumidification (fan and compressor) control humidity control is desired, consider using the built-in control.
  • Page 10: Wiring Of Digital Control

    Clean Comfort Ventilating Dehumidifier Circuit Breaker To prevent damage to the 24 volt control transformer, the DV070 comes with a resettable circuit breaker. Check wiring for any electrical short and repair before resetting breaker. Resetting the circuit breaker without correcting the electrical short may result in transformer damage.
  • Page 11: Digital Humidifier And Ventilation Control

    Clean Comfort Dehumidifier & Major Operations Ventilation System Control • Digital control of Relative Humidity (Digital Set-Point) When used with Clean Comfort Whole House Ventilating • Fan/Filter Operation Dehumidifiers, the DVP-4034748 and DVP-4034753 • Programmable Ventilation Timer digital controls allow homeowners the ability to monitor and control relative humidity levels in their home.
  • Page 12: Maintenance

    To replace the filter, remove the filter door from one of intake port seasonally. The screen may become plugged the sides of the DV070 Dehumidifier by pushing the snap during seasons when there are many particles in the button in and gently pulling to door away from the body outdoor air.
  • Page 13: Wiring Schematic

    WIRING SCHEMATIC Wiring Schematic for DV070 GRN-1 COMPRESSOR DEFROST RELAY SWITCH COMPRESSOR DEHUMIDISTAT BLK-10 CIRCUIT BLK-11 BLK-10 BLK-28 COMPRESSOR CAPACITOR BREAKER YEL-33 BLU-19 YEL-7 WHT-3 RED-8 BLK-28 RED-8 DEHU N.C. BLK-11 N.O. BLK-6 BLU-9 BLK-12 DMPR BLK-13 GRN-25 COIL RED-20...
  • Page 14: Service Parts List

    Compressor Relay, SPST, 24VAC, 30A Technical Description of Dehumidifier Operation The DV070 uses a refrigeration system similar to an air conditioner's to remove heat and moisture from incom- ing air, and add heat to the supply air that is discharged from the dehumidifier.
  • Page 15: Troubleshooting

    8. Defective compressor. 2. Defective compressor overload. 9. Restrictive ducting. 3. Defective compressor. 10. Optional Condensate Pump Safety Float Switch open. 4. Defrost thermostat defective. 5. Dirty air filter(s) or air flow restricted. 6. Defective fan relay. WWW.CLEANCOMFORT.COM IO-DV070...
  • Page 16: Refrigerant Charging

    The Clean Comfort 5. Remove the digital control panel from the mounting DV Series dehumidifier is equipped with an automatic box and detach it from the field installed control defrost mechanism.
  • Page 17: Motorized Ventilation Damper

    1. Check that the wiring is correct and that voltage is present at the damper motor. 2. Check for any obstruction inside the damper. If the electric ventilation damper fails to operate after performing these checks, it must be replaced. WWW.CLEANCOMFORT.COM IO-DV070...
  • Page 18: Condensate Pump Installation

    Step 2. Partially screw in the leveling feet at the four Step 1. Lay the DV070 unit on it's side. Make sure locations. the drain hole is facing upward. Note the locations of the four leveling feet and the hose adaptor.
  • Page 19: Warranty

    Daikin North America LLC (“Daikin”) warrants as follows: the warranty time period remaining on the original Product or Clean Comfort dehumidifier (“Product”) will be free of material Component. This limited warranty does not cover any costs defects in workmanship or materials for a period of five (5) years...
  • Page 20 Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. ©2017 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. WWW.CLEANCOMFORT.COM • TECHNICAL SUPPORT: 1-833-40-CLEAN (25326) IO-DV070...

Table of Contents