Technical data
Pressure ratio
Total length
Pump tube length
Pump tube diameter
Air motor diameter
Stroke length
Weight
Max. air pressure
Min. air pressure
Max. fluid pressure
Burst pressure
Free delivery (water at 0.7
Mpa/100 psi air pressure)
Recommended max.
delivery
Air connection
Fluid outlet
Fluid inlet
Noice level at 0.7 Mpa/100
psi
Drumadapter, 111 72 77
Suction tube, 122 62 94,
required when mounting
in drum
1.
(EN) General
The air operated pump has two main parts. One double acting air motor driving a double acting liquid pump.
The fluid is sucked into the pump through the bottom valve when the piston is on the upward stroke. The fluid is
discharged in both up- and downs strokes.
The relationship between then area of the air piston and area of the pump decides the pressure ratio. The pressure
ratio is 4:1 and the theoretical pressure when the pump has stopped is 4 times higher than the air pressure.
The exhaust air is blown out through a silencer made of sintered brass.
All parts in contact with fluid are made of stainless steel (ISO 2346 and similar). The central bar is nickel plated.
All packings in contact with fluid are manufactured of PTFE (Teflon).
Important! Avoid operating the pump without fluid present, running the pump dry will damage the packings.
For the same reason it is recommended to prime the pump with fluid before starting it.

1.1. Safety precautions

The pump is to be used with water based fluids like windscreen liquid, glycol/water mixture and non-
lubricant fluids like kerosene, white spirit, lacquer solvent and similar.
The pump may not be use for pumping petrol.
Check that all accessories and components are suitable for the distributed fluid and the working pressure of
the system.
The system must be tested to 1.3 times the working pressure before being put into operation.
Do not exceed the maximum air pressure of the pump, 1.0 MPa.
Close and disconnect the air supply and relieve the liquid pressure in the system before any work to the
pump or system is carried out
Only use genuine manufacturers spare parts. Never use worn or damaged spare parts.
Do not direct outlet valves or any other dispensing valve against the body or any other person as the liquid
can penetrate the skin or damage the eyes.
Always turn off the air pressure to the pump when the premises are unattended.
2
EUROLUBE EQUIPMENT
205149
4:1
585mm/ 23"
220mm/ 8.6"
Ø 54 mm/ 2.1"
Ø 80 mm/ 3.15"
Approx. 100mm /4"
9.0kg/ 19.8 lbs
1 Mpa/ 145 psi
0.4 Mpa/ 58 psi
4.0 Mpa/ 580 psi
Min. 10.0 Mpa/ 1450 psi
Approx. 30 l/min
Approx. 20 l/min
BSP ¼" female/ G ¼"
BSP 1" female/ G 1"
BSP 1" female/ G 1"
84 dB
Included
Not included
www.eurolube.com
Tekniska data
Tryckförhållande
Totallängd
Pumprörslängd
Pumprörsdiameter
Luftmotordiameter
Slaglängd
Vikt
Max. lufttryck
Min. lufttryck
Max. vätsketryck
Sprängtryck
Fritt avgivet vätskeflöde
(vatten vid 0.7 Mpa
lufttryck)
Rekommenderat max. flöde
Luftanslutning
Vätskeutlopp
Vätskeinlopp
Ljudnivå vid 0.7 Mpa
lufttryck
Fatadapter, 111 72 77
Sugrör, 122 62 94, för
användning vid fatmontage
4:1
585mm
220mm
Ø 54 mm
Ø 80 mm
ca 100mm
9.0kg
1 Mpa
0.4 Mpa
4.0 Mpa
Min. 10.0 Mpa
ca. 30 l/min
ca. 20 l/min
G ¼" inv.
G 1" inv.
G 1" inv.
84 dB
Ingår
Ingår ej
3(11)

Advertisement

Table of Contents
loading

This manual is also suitable for:

12745-46

Table of Contents