Troubleshooting - Jorjin WB2072E00A Quick Start Manual

Bluetooth low energy wireless mcu module evaluation kit
Table of Contents

Advertisement

ST BLE Sensor app
environment

3. Troubleshooting

The following section reports some tips to be followed if the WB2072E00A platform is not
recognized as a CMSIS-DAP device once connected to a PC USB port, or if user is not able to
connect/debug to the selected platform through a CMIS-DAP programmer/debug tool:
1. The WB2072E00A platform starts always in "MAINTENANCE" mode.
a. The USB_CMSISDAP firmware is not loaded. Follows the instructions in the
WB2072E00A user guide, section 2.9.4"USB_CMSISDAP firmware update" in order to
load the USB_CMSISDAP firmware. Please notice that this condition is not expected,
since the USB_CMSISDAP firmware is programmed at WB2072E00A manufacturing
time.
b. The application loaded in the WB2072-00 module makes the device continuously reset.
Since the RTSN signal is used at the startup by the USB_CMSISDAP firmware for
choosing to start in "MAINTENANCE" mode or not, it is necessary to disconnect the
RSTN signal of the WB2072-00 module from the USB_CMSISDAP. In order to do it, user
must perform the following steps:
1.) Remove the jumper JP4.
acceleration plot
©
Copyright
JORJIN TECHNOLOGIES INC. 2020
http://www.jorjin.com.tw
CONFIDENTIAL
Doc No: WB2072E00A-QSG-D01
called "WB-2072LP"
Gyroscope plot
RSSI characteristic
Page 6

Advertisement

Table of Contents
loading

Related Products for Jorjin WB2072E00A

This manual is also suitable for:

Wb2072-00

Table of Contents