ironLogic Z-396 EHT User Manual

Rfid electronic furniture lock with em-marine & hid proxcard ii & atmel (t5557) reader (125 khz) and standalone controller

Advertisement

Quick Links

Z-396 EHT
Z-396 EHT RFID Electronic Furniture Lock
with EM-Marine & HID ProxCard II & Atmel (T5557) reader (125 kHz)
1. OVERVIEW
Z-396 EHT electronic lock is a contactless reader combined with a standalone controller and
electromechanical lock. The lock is powered by four AA type batteries. Compact, with five operational
modes, easy in installation, programming and servicing, this lock is a perfect access control solution for
various storage places: gym lockers, changing cabins, office furniture, trade equipment. Particularly
broad application of these locks happens in places like SPA, water parks, gyms, swimming pools.
A Z-396 EHT lock can be installed as a standalone device, or as a part of a complex access control
solution. For access keys, it accepts contactless key fobs and bracelets. Z-395 EHT can operate in five
different modes:
- Gym Mode: keys are not tied to locks. Any key can open and close any free locker.
- Logic Mode: keys are not tied to locks. Any key can open and close any free locker. The number of
used locker and battery levels are stored into keys. This is convenient when the user forgets which
locker he used. Can set the maximum for the number of lockers per one user (range 1 to 15).
Computerized logging and lock setup. Only works with Lock Manager software.
- General Mode: a typical lock controller operation: only the key(s) stored in the lock's memory
(maximum 24) can open that lock.
- Safe Deposit Box Mode: the lock emulates safe deposit box operation. To open the lock, all the
keys in controller database (max. 26) must be swipe to it, one after another.
- Custom Mode: you can design your own custom operational logic, subject to your needs. Then
obtain updated firmware from the Manufacturer and download it into the lock with an RF-1996 adapter.
Programming of operational modes, Master and User cards, is done via Reset button on the lock's case
(see Chapters 4 to 11) or via Lock Manager software using an RF-1996 adapter (see Chapter 12).
Selected modes and cards database are stored in the lock's NVRAM (non-volatile memory).
After one of the modes selected and all configuration done, the lock starts to work according to these
rules:
On key swipe to the lock's reader,
- if the token has access granted, a beep sounds and the LED flashes green, or else
- if the token has access denied, a beep sounds and the LED flashes red.
and standalone controller
User Manual
www.ironlogic.me
page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Z-396 EHT and is the answer not in the manual?

Questions and answers

Summary of Contents for ironLogic Z-396 EHT

  • Page 1 SPA, water parks, gyms, swimming pools. A Z-396 EHT lock can be installed as a standalone device, or as a part of a complex access control solution. For access keys, it accepts contactless key fobs and bracelets. Z-395 EHT can operate in five different modes: - Gym Mode: keys are not tied to locks.
  • Page 2: Specifications

    Z-396 EHT www.ironlogic.me Z-396 EHT Electronic Lock Operational Modes Comparison Table. Features Operational Modes Logic* General Safe Deposit Box Custom Any key can open/close any locker Limit on lockers number that can be taken by one bracelet. The operator defines the maximum lockers number for one bracelet (1…15)
  • Page 3 Z-396 EHT www.ironlogic.me Installation onto a wooden (chipboard) locker Make a 25 mm hole in the locker's door. To mark the hole position Connect cable to lock's PCB. use template from Fig. 13. Note: Check that cable socket is firmly connected with lock's PCB socket.
  • Page 4 Installation onto a metal locker Due to the particular design of the metal lockers, the NAK-1 spacers kit may be required. The Z-396 EHT mounting with their use is shown below. Mount the NAK-1 spacer from the inside of the locker`s door.
  • Page 5 Z-396 EHT www.ironlogic.me How to install the Z-396 EHT lock properly Top view Lock push bolt unit View from inside the door Lock's latch push bolt unit page 5...
  • Page 6 Z-396 EHT www.ironlogic.me 4. INITIAL POWER-UP, ADDING MASTER KEYS BY RESET BUTTON Initial power-up sequence (No keys in lock's memory) - Connect the reader module to the lock module by a supplied cable. - Insert four AA batteries. - Swipe the reader by any EM-Marine key.
  • Page 7 Z-396 EHT www.ironlogic.me 6. GYM MODE Note: Cannot select an operational mode without a Master key. Rules of operations for Gym mode: 1. Opening the lock is possible with the key recorded when door was locked. 2. Locking is only possible when the lock is open (latch hidden within the lock);...
  • Page 8: Logic Mode

    Logic mode can only work with Lock Manager software and Z-2 USB RF-1996 adapter. Logic mode can also only work with Atmel (T5557) keys. Additional Information about Logic mode operation can be found on the ironlogic.me website. Rules of operations for Logic mode: 1.
  • Page 9: General Mode

    Z-396 EHT www.ironlogic.me 8. GENERAL MODE Note: Cannot select an operational mode without a Master key. Rules of operations for General mode. 1. Opening the lock is possible by the key recorded in lock's memory. 2. On 1st key swipe to lock's reader, the latch comes OUT, a beep sounds and the LED flashes green, the user can now put their possessions inside and close the door.
  • Page 10 Z-396 EHT www.ironlogic.me 9. SAFE DEPOSIT BOX MODE Note: Cannot select an operational mode without a Master key. Rules of operations for Safe Deposit Box mode. 1. The latch is always released (OUT), if the database is not empty; 2. Opening the lock is possible by swiping ALL the keys to the reader, one after another.
  • Page 11: Reset To Factory Defaults

    Z-396 EHT www.ironlogic.me 10. ERASING OF ALL MASTER KEYS This function erases all Master keys from lock's database, leaving only the Normal keys intact. Also cancels the currently selected operating mode. To erase all Master keys, please perform the following steps: a.
  • Page 12: Emergency Opening

    Z-396 EHT www.ironlogic.me 13. BATTERY DISCHARGE INDICATION AND REPLACEMENT With 1,500 mAh alkaline batteries, the lock is guaranteed to open at least 10,000 times, or to work 2.5 years in stand-by mode. The lock controls the battery charge and informs the users that batteries need to be replaced.
  • Page 13: Additional Accessories

    Z-396 EHT www.ironlogic.me 15. ADDITIONAL ACCESSORIES Detailed information about all additional accessories can be found on the ironlogic.me website. Metallic lock cover NAM-2 Snaps onto the internal part of the lock. Provides attractive appearance and anti-vandal protection. Set of spacers NAK-1 This set is intended for installation of locks on the metallic lockers.
  • Page 14 Z-396 EHT www.ironlogic.me 19. IRONLOGIC CONTACTS Headquarters: RF Enabled ID Limited 34 Ely Place, London, EC1N 6TD, UK E-mail: marketing@rfenabled.com Development and production: AVS LLC 7, Bobruiskaya street, Saint-Petersburg, 195009, Russian Federation E-mail: marketing@rfenabled.com Phone: +78122411853; +78125421185 www.ironlogic.ru Authorized representative in the European Union:...
  • Page 15 Z-396 EHT www.ironlogic.me Holes Layout for Z-396 EHT installation onto a wooden (chipboard) locker, with door`s thickness in 16 mm. 68 mm* - size depends on locker chipboard wall thickness Locker`s wall Locker`s door Fig.13 page 15...
  • Page 16 Z-396 EHT www.ironlogic.me Holes Layout for Z-396 EHT installation onto a metal locker. Important note! The size and design features of the doors of metal lockers usually varies from manufactuter to manufacturer. Please consult with us before installation. 3 mm 2 holes.

Table of Contents