ironLogic Z-395 EHT User Manual

Rfid electronic furniture lock with em-marine & hid proxcard ii & atmel (t5557) reader (125 khz) and standalone controller

Advertisement

Quick Links

Z-395 EHT
Z-395 EHT RFID Electronic Furniture Lock
with EM-Marine & HID ProxCard II & Atmel (T5557) reader (125 kHz)
1. OVERVIEW
Z-395 EHT electronic lock is a contactless reader combined with a standalone controller and
electromechanical lock. The lock is powered by four AA type batteries. Compact, with five
operational modes, easy in installation, programming and servicing, this lock is a perfect access
control solution for various storage places: gym lockers, changing cabins, office furniture, trade
equipment. Particularly broad application of these locks happens in places like SPA, water
parks, gyms, swimming pools.
A Z-395 EHT lock can be installed as a standalone device, or as a part of a complex access
control solution. For access keys, it accepts contactless key fobs and bracelets. Z-395 EHT can
operate in five different modes:
- Gym Mode: keys are not tied to locks. Any key can open and close any free locker.
- Logic Mode: keys are not tied to locks. Any key can open and close any free locker. The
number of used locker and battery levels are stored into keys. This is convenient when the user
forgets which locker he used. Can set the maximum for the number of lockers per one user
(range 1 to 15). Computerized logging and lock setup. Only works with Lock Manager software.
- General Mode: a typical lock controller operation: only the key(s) stored in the lock's
memory (maximum 24) can open that lock.
- Safe Deposit Box Mode: the lock emulates safe deposit box operation. To open the lock, all
the keys in controller database (max. 26) must be swipe to it, one after another.
- Custom Mode: you can design your own custom operational logic, subject to your needs.
Then obtain updated firmware from the Manufacturer and download it into the lock with
an RF-1996 adapter.
Programming of operational modes, Master and User cards, is done via Reset button on the
lock's case (see Chapters 4 to 11) or via Lock Manager software using an RF-1996 adapter
(see Chapter 12). Selected modes and cards database are stored in the lock's NVRAM (non-
volatile memory).
After one of the modes selected and all configuration done, the lock starts to work according to
these rules:
On key swipe to the lock's reader,
- if the token has access granted, a beep sounds and the LED flashes green, or else
- if the token has access denied, a beep sounds and the LED flashes red.
and standalone controller
User Manual
www.ironlogic.me
page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Z-395 EHT and is the answer not in the manual?

Questions and answers

Summary of Contents for ironLogic Z-395 EHT

  • Page 1 Particularly broad application of these locks happens in places like SPA, water parks, gyms, swimming pools. A Z-395 EHT lock can be installed as a standalone device, or as a part of a complex access control solution. For access keys, it accepts contactless key fobs and bracelets. Z-395 EHT can operate in five different modes: - Gym Mode: keys are not tied to locks.
  • Page 2: Specifications

    Z-395 EHT www.ironlogic.me Z-395 EHT Electronic Lock Operational Modes Comparison Table. Features Operational Modes Logic* General Safe Deposit Box Custom Any key can open/close any locker Limit on lockers number that can be taken by one bracelet. The operator defines the maximum lockers number for one bracelet (1…15)
  • Page 3 Z-395 EHT www.ironlogic.me Installation onto a wooden (chipboard) locker Make a 35 mm hole in the locker's door. To mark the hole position Install the lock's push bolt unit onto the locker's wall (see Fig. 3, use template from Fig. 13.
  • Page 4 Z-395 EHT www.ironlogic.me How to install the Z-395 EHT lock properly Top view Lock push bolt unit View from inside the door Lock's latch push bolt unit page 4...
  • Page 5 Z-395 EHT www.ironlogic.me 4. INITIAL POWER-UP, ADDING MASTER KEYS BY RESET BUTTON Initial power-up sequence (No keys in lock's memory) - Connect the reader module to the lock module by a supplied cable. - Insert four AA batteries. - Swipe the reader by any EM-Marine key.
  • Page 6 Z-395 EHT www.ironlogic.me - Press the RESET button shortly (once). The lock issues audible and visual signals once. The lock is now in Gym Mode again. - To confirm the selected mode, do nothing for 6 s. After 6 s, audible and visual signals acknowledge the exit from the Operational Mode selection.
  • Page 7: Logic Mode

    Logic mode can only work with Lock Manager software and RF-1996 adapter. Logic mode can also only work with Atmel (T5557) keys. Additional Information about Logic mode operation can be found on the ironlogic.me website. Rules of operations for Logic mode: 1.
  • Page 8: General Mode

    Z-395 EHT www.ironlogic.me 8. GENERAL MODE Note: Cannot select an operational mode without a Master key. Rules of operations for General mode. 1. Opening the lock is possible by the key recorded in lock's memory. 2. On 1st key swipe to lock's reader, the latch comes OUT, a beep sounds and the LED flashes green, the user can now put their possessions inside and close the door.
  • Page 9 Z-395 EHT www.ironlogic.me 9. SAFE DEPOSIT BOX MODE Note: Cannot select an operational mode without a Master key. Rules of operations for Safe Deposit Box mode. 1. The latch is always released (OUT), if the database is not empty; 2. Opening the lock is possible by swiping ALL the keys to the reader, one after another.
  • Page 10 Z-395 EHT www.ironlogic.me 10. ERASING OF ALL MASTER KEYS This function erases all Master keys from lock's database, leaving only the Normal keys intact. Also cancels the currently selected operating mode. To erase all Master keys, please perform the following steps: a.
  • Page 11 Z-395 EHT www.ironlogic.me 13. BATTERY DISCHARGE INDICATION AND REPLACEMENT With 1,500 mAh alkaline batteries, the lock is guaranteed to open at least 10,000 times, or to work 2.5 years in stand-by mode. The lock controls the battery charge and informs the users that batteries need to be replaced.
  • Page 12: Additional Accessories

    Z-395 EHT www.ironlogic.me 15. ADDITIONAL ACCESSORIES Detailed information about all additional accessories can be found on the ironlogic.me website. - Metallic lock cover (NAM2) Snaps onto the internal part of the lock. Provides attractive appearance and anti-vandal protection. - External power module Provides power for locks.
  • Page 13 Z-395 EHT www.ironlogic.me 19. IRONLOGIC CONTACTS Headquarters: RF Enabled ID Limited 34 Ely Place, London, EC1N 6TD, UK E-mail: marketing@rfenabled.com Development and production: AVS LLC 7, Bobruiskaya street, Saint-Petersburg, 195009, Russian Federation E-mail: marketing@rfenabled.com Phone: +78122411853; +78125421185 www.ironlogic.ru Authorized representative in the European Union:...
  • Page 14 Z-395 EHT www.ironlogic.me Holes Layout for Z-395 EHT installation onto a wooden (chipboard) locker. Locker`s wall Locker`s door Fig.13 A* -- the size is calculated, depending on locker chipboard wall thickness. page 14...

Table of Contents