Maintenance Calendar; Maintenance Techniques - Drolet ECO-55 ST Operation Manual

Hide thumbs Also See for ECO-55 ST:
Table of Contents

Advertisement

Available languages

Available languages

6.4 MAINTENANCE CALENDAR

NOTICE
Cleaning frequency may vary depending on the
type of fuel used. Fuel with higher ash content will
increase cleaning frequency.
The cleaning frequency suggested in the following
section applies to normal use of the appliance. Each
step of the maintenance is illustrated in detail in the
following sections.
DAILY MAINTENANCE
1.
Activate the cleaning rod a few times.
2.
Empty the burn pot.
3.
Wipe the glass.
WEEKLY MAINTENANCE (+/- 10 BAGS)
1.
Activate the cleaning rod a few times.
2.
Empty and brush the baffle.
3.
Empty and scrape the burn pot.
4.
Vacuum cold ashes from the combustion chamber
or push them in the ash drawer.
5.
Clean the glass.
BIANNUEL MAINTENANCE (+/- 25 BAGS)
1.
Vacuum cold ashes from the exhaust tubes and
from the heat exchanger.
2.
Brush the combustion chamber and vacuum the
cold ashes from the combustion chamber or push
them in the ash drawer.
3.
Inspect the venting system.
4.
Inspect all gaskets.
ANNUAL MAINTENANCE (+/- 1 TON)
1.
Sweep venting system.
2.
Empty and vacuum hopper.
Page 10

6.5 MAINTENANCE TECHNIQUES

6.5.1 BURN POT
Remove and empty burn pot.
Scrape, when necessary.
6.5.2 Glass
Vacuum the ashes that may have accumulated into
the airwash system inlet between the bottom glass
retainer and the glass. This will allow an optimum air
flow along the inside portion of the glass and prevents
the glass from sooting-up.
Clean the glass when necessary. The use of a stove
glass cleaner is recommended. Regular household
glass cleaners will not remove creosote properly.
OPERATION MANUAL ECO-55 / ECO-55 CT / ECO-55 ST

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eco-55, eco-55 ctDp00072Dp00070Dp00071