Bosch WQG233D1BY User Manual And Installation Instructions page 38

Tumble dryer
Table of Contents

Advertisement

en Troubleshooting
Fault
The drying time is too
long.
Water is leaking from
the appliance.
The laundry is too
damp.
38
Cause and troubleshooting
The base unit's filter is soiled.
→ "Cleaning the filter system on the base unit",
Page 29
Fluff filter is soiled.
→ "Cleaning the fluff filter", Page 28
The ambient temperature is greater than 30 °C.
Ensure that the ambient temperature is lower than
30 °C.
The ambient temperature is lower than 15 °C.
Ensure that the ambient temperature is above 15
°C.
Insufficient air circulation at the appliance's installation
location.
Ventilate the appliance's installation location.
Appliance air inlet is blocked.
Ensure that the air inlet on the appliance is kept
clear.
Heat exchanger is soiled.
→ "Opening the base unit", Page 32.
1.
Clean the heat exchanger.
2.
→ "Cleaning the base unit", Page 33
→ "Closing the base unit", Page 35.
3.
Appliance is not correctly aligned.
Aligning the appliance
The seal for the heat exchanger cover is dirty.
Clean the seal for the heat exchanger cover.
→ "Cleaning the filter system on the base unit",
Page 29
The lever for the heat exchanger cover is not closed
correctly.
Ensure that the lever for the heat exchanger cover
is closed correctly.
→ "Closing the base unit", Page 35
Unsuitable programme for the type of fabric.
Set a timed programme for the subsequent drying.
→ "Programmes", Page 24
There has been a power cut.
Check whether the lighting in your kitchen or other
appliances are working.
The load is too large.

Advertisement