Chapter 4 | Schedules Chapter 1 | General What are schedules and how Notes on this manual do I create/change them? Function and design of the H1 How do I pause a schedule (vacation Technical details mode)? Delete all schedules...
If the direct radio link between gateway and H1 is not available in your facility (e.g. due to interfering factors such as walls, doors, etc.), you may have to integrate additional Zigbee components that are permanently connected to the mains into your system.
Page 6
Chapter 1 | General Design H1 Display Mounting ring Battery protection foil Button Rotary dial 55 mm 100 mm Heating Control H1...
Battery life up to 4 Jahre Power consumption standby 90 μW Power consumption maximum Aktive 450 mW Dimensions 55 x 100 mm Display size 1,68“ (active area) (W: 33,02 x H: 26,96 mm) Weight (with batteries) 250 g Heating Control H1...
This is followed by the commissioning in combination with the ubisys G1 and the ubisys Smart Home App. Be- fore you start this, you should have commissioned the ubisys G1. If you want to operate the H1 using a gateway and accompanying app of another manufacturer, please follow the corresponding instructions of that manufac- turer.
Page 10
Chapter 2 | Commissioning Initial commissioning in combination with the ubisys G1 and the ubisys Smart Home App: Open the ubisys Smart Home App. Tap on Configuration -> Basic Configuration -> Open for new devices. The Zigbee network is now open for about 4 minutes and your H1 heating controller can join the network.
Page 11
Your heating valve is stuck so that the H1 cannot move it in • Your heating valve is too long or too short so that the H1 cannot start the calibration process Following the calibration, the device performs the network startup and tries to connect to an open Zigbee network.
Page 12
| Commissioning 12. At the same time, the app automatically jumps back to the start screen as soon as the H1 is in the Zigbee network. The device is recognized as a new component and displayed accordingly: 13. After 4 seconds of inactivity, the display will turn off. To „wake up“...
10 and 11 in the „ubisys Smart Home Quickstart“. 2.3 Date and time setting To be able to create schedules for your Heating Control H1, you must first set the current date and time. Pro- ceed as follows for this: Press and hold the button for 10 seconds to enter the second menu.
Page 14
12. The last two numbers (minutes) flash. Use the rotary knob to select the current minutes and confirm by pressing the button. 00:00 2021.09.30 0°C Note: To cancel the process, press and hold the button for two seconds. Heating Control H1...
The desired room temperature can be set manually on the device using the rotary dial. Pay attention to the display, which shows you the set temperature (center) and the actual temperature (bottom right). Via ubisys app Open the ubisys app. Tap on „Building Control“. Heating Control H1...
Page 17
Chapter 3 | Set Room Temperature Tap on the room where the radiator with the H1 is located. To set the desired room temperature, touch the actual temperature displayed [ 21.0°C ]. A slider for setting the target temperature will appear. Move the slider to the position with the desired temperature (in this case 20.0°C).
„frost protection“ (approx. 7°C). The H1 is now in a kind of „sleep mode“ - but is still accessible via the gateway. You may now still change the set temperature in the app, but the device and thus the heating will not respond.
To compensate for such temperature differences, the H1 offers a correction option of up to +10°C or -10°C. For example: If it is 3°C warmer in the room than it is displayed on the H1 or in the ubisys app, +3°C must be entered in the corresponding menu on the H1.
For example, if you have created only one time window on a day - e.g. 16:00 - 23:00, target temperature: 22°C – and the time window ends, the temperature that was last set manually (on the H1 directly or in the app) is au- tomatically restored.
Page 22
Create schedule 06:00 Note: To be able to create a schedule, you must have entered the current date and time on your H1 before- 6-9::22.0°C 9-17::17.0°C hand. If you have not yet done so, you will automatically be guided to the corresponding menu.
Page 23
2:00 6-9::22.0°C the display is deactivated. When you activate the display again via 9-17::17.0°C the button or the rotary dial, you will be on the start page. 06:00 06:00 2°C 09:00 09:00 .0°C 22.0°C 22.0°C 0°C Heating Control H1 6-9::22.0°C...
Page 24
To adjust a schedule that has already been created, proceed as follows: Press the button to activate the display. Press the button again to enter the first menu. 1x + 1x Select the „Schedule“ icon by turning the dial and press the button to confirm. Heating Control H1...
Page 25
To be able to select the options in the right column, you 9-17::17.0°C must have confirmed start time ( ), stopp time ( ) and target temperature ( ) by button. 06:00 06:00 06:00 09:00 09:00 09:00 22.0°C 22.0°C 22.0°C 2.0°C 17.0°C Heating Control H1...
The set temperature is now automatically regulated to approx. 16°C. End vacation mode To end the „vacation mode“, simply set a new target temperature by turning the rotary dial. Your time schedules are now also active again. Heating Control H1...
Press the button to activate the display. Press the button again to enter the first menu. 1x + 1x Select the „Delete all schedules“ icon by turning the dial and press the button to confirm. All schedules are deleted. Heating Control H1...
Page 29
Chapter 5 More Functions and Information Heating Control H1...
H1. These may contain new functions or possible error corrections. For this you need the ubisys gateway G1 or another Zigbee capable gateway. The H1 has an over-the-air update function, i.e. the device can be supplied with new firmware versions via the gateway using Zigbee radio technology.
If the calibration process fails again, there may be a problem with your heating valve: • Your heating valve is stuck, so that the H1 cannot move it in. • Your heating valve is too long so that the H1 cannot start the calibration process.
Finding/Binding is essentially used to let Zigbee devices communicate with each other – usually when no gate- way is present. If a gateway is present, it takes over the communication. At the H1 you have the possibility to configure it as „initiator“ or as „target“ (by selecting the corresponding icon in the menu).
Page 33
Operate the rotary wheel to the right. If you turn the rotary knob to the left, the process will be is canceled and you return to the menu mode. 0°C 55 mm 100 mm Heating Control H1...
If you want to cancel now, press the button. You will then return to the menu mode. 5.6 Unmounting In order to facilitate the disassembly, you should allow the ram of the H1 to retract. Proceed as follows for this: Press and hold the button for 10 seconds to enter the second menu.
5.7 Factory reset In case of unexpected problems with your H1 that cannot be solved by means of the standard settings, you may reset the device to factory settings. This resets the H1 to the factory settings. Proceed as follows: Press and hold the button for 10 seconds to enter the second menu.
Page 36
If you turn the rotary dial to the left, the process will be canceled and you return to the menu mode. The symbol for „Factory reset“ appears with a check mark. 10. Press the button. 11. The device is reset to factory settings. 55 mm 00 mm Heating Control H1...
5.8 Overview of the symbols on the display and their meaning Power on Displayed when the device boots up (at the beginning). Calibrate Measurement process for matching the H1 tappet to the radiator valve. Calibrate Calibration was completed successfully. Calibrate Calibration was not completed successfully.
Page 38
Battery symbol much filled = battery level high Battery symbol little filled = battery level low Schedule Offers the possibility to create automated heating phases. 00:00 2021.09.30 0°C Delete all schedules Deletes all created schedules. 00:00 2021.09.30 0°C 0°C Heating Control H1...
Page 39
This feature is primarily used to fulfill certification-relevant requirements. This function is not used in everyday use. Finding/Binding The device shall get its function („initiator“ or „target“) during the fin- ding/binding process within the Zigbee network. Heating Control H1...
Page 40
Factory reset Security query, whether the device should really be reset to factory settings. Factory reset Security query whether the factory reset should be canceled. Unmounting The device retracts the plunger completely to facilitate dismounting. 2021.09.30 0°C Heating Control H1...
The smart heating controler H1 is maintenance-free for the user except for battery replacement. As soon as the low battery condition is signaled in the display or in the ubisys smart home app, the batteries must be replaced. The surface must not be cleaned with sponges and scouring agents. This will result in scratches or a dull sur- face.
Need help?
Do you have a question about the H1 and is the answer not in the manual?
Questions and answers